Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@Lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road, Jiading District
Shanghai, 201802
China
-
Product
Lamp Start, Run-up time and Flicker Test
LSRF-2
-
The (EU) NO 1194/2012rules
. Compared with which posted by theEuropean Commission Regulation (EC) NO 244/2009 Regulations dated 18th March, 2009, the new rules have complete mandatory and eco-design requirements. Start and Run-up time as the two indicators functional requirements in the industry has been more emphasis by manufacturers. -
Product
DIP LED Aging Tester
LS6100
-
Designed to measure the aging-life and color comparisons of 260pcs DIP LED. • 260 separate constant current supply • Aging functions: constant current, impact pulse, on-off mode • Range of forward voltage(VF): 5.0V • Range of forward current(IF): 1) constant current: 0-100.0mA 2) Impact pulse: 0-200.0mA • Range of impact pulse frequency: 10-9999Hz; Duty ratio: 1%-99% • Range of on-off circle: 0-9999H59M59S • Range of on-off times: 0-9999times • Range of aging time: 0-9999H59M59S
-
Product
LED Luminous Intensity Distribution Tester
LS860
-
LS860 Luminous Intensity Distribution Tester is a precise electronic instrument for measuring LED luminous intensity. It’s strictly designed according to LED standard requirements of CIE 127-1997 A or B Condition.
-
Product
Digital CC and CV DC Power Supply
DC3005
-
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and can output costant current or constant voltage. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer’s request.
-
Product
Lamp Cap Temperature Rise Test System
TMP-L
-
TMP-L is according to IEC60360-1998 and GB2512-2001 (Standard method of measurement of lamp cap temperature rise). It is used to test the working and environmental temperature as well as temperature-rise of the burner and lamp. It meets the requirement of IEC and GB Standards.
-
Product
Wire Damaged Tester
WDT-1
-
This equipment is designed and manufactured according to corresponding regulation in standard IEC884-1, GB299.1-96, GB16915.1-97 and other electronic accessories relevant standard. Mainly used to test damage degree of fixed connection components lead wire of with thread clamping type and no screw terminals, so as to inspect whether it can withstand mechanical stress during normal use.Specification: • Power supply: AC220V 50Hz • Test rate: 10±2r/min (GB16915.1-97: 12 ±1r/min) • Rotating radius: 100mm • Test distance: 250~500mm adjustable • Test numbers (Number of rotating): 0~999999 any set • Mass: 0.3KG, 0.4KG, 0.7KG, 0.9KG, 1.4KG, and 2.0KG (GB16915.1-97: 30N, 40N, 50N, 60N each of 2 pcs) • Stations: 2 • Dimension: 1200×1400×400 (mm) • Remarks: The mass and rotating radius can be optional as per customer requirements.
-
Product
LED Test Instruments
-
Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
Product
Electrolytic Capacitor Tester
HF2686C
-
Test voltage: 0-200V/0-500V• Output current range: 0.1μA-30mA• Maximum charge current: 200mA ±10%• Charge time: 0.5s/1s/2s/3s/4s/5s/7s/10s/30s/60s• Accuracy: ±2%
-
Product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
-
Cabinet Shell2mm galvanized cold-rolled steel sheetCabinet Door0.9*1.7m(L*W)0.6*0.6mCabinet Window0.3*0.3*0.025m(L*W*T) with 4mm holeN/APower Supply Filter30A/220V30A/220VInternet Line FilterRJ-45N/ACabinet Inside DecorationPVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size2*1.2*1.8m0.8*0.8*0.8mAfter Packing Size2.2*2.3*2.3m1*1.1*1.2mAfter Packing Weight800kg200kgWorking With EMI-9KA/EMI-9KBEMI-9KA/EMI-9KB, PC, Testing load, and operator insideTesting load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
Product
Electronic Ballast Tester
-
LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards
-
Product
LCR Digital Bridge
FD2810B
-
• Test parameter: C, R, L, Z, D, Q• Test frequency: 100Hz, 120Hz, 1kHz, 10kHz• Test level range: 0.1V, 0.3V, 1.0V• Output impedance: 30Ω, 100Ω• Slow or fast (15 times/s)• Automatic selecting, out of limit alarming• Provide the RS-232 & HANDLER interface• Accuracy: 0.1%
-
Product
Integrating Sphere Spectroradiometer System for LED
LPCE-2(LMS-8000)
-
LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 127-1997 and IES LM 79-08 standards, it recommends using an array spectroradiometer with integrating sphere and photometer head to test SSL products. LISUN GROUP developed LPCE-2 test system for LED products.
-
Product
AC and DC Power Supply
-
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and simple operation. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer's request.
-
Product
Masks Respiratory Resistance Tester
WKS-1200
-
WKS-1200 Masks Respiratory Resistance Tester applies to determining the inhalation resistance and exhalation resistance of respirators and mask protective products under specified conditions, and used for the relevant testing and inspection of ordinary mask products by the national labor protection equipment inspection agency or manufacturer.
-
Product
Luminance Colorimeter
XYL-VI
-
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.















