Applied Image, Inc.
APPLIED IMAGE Inc. is a world leader in the design and manufacture of precision-imaged optical components intended for a wide range of applications and industries that require NIST-traceable standards and/or precision-imaged components to test, calibrate, align, control or measure their optical or photonics systems. In addition to its large catalog of standard products, APPLIED IMAGE specializes in designing and manufacturing custom components, imaged to the strictest tolerances. Its mission is to provide the highest-quality products and customer service to consistently meet and exceed the expectations of its customers such as NASA (Mars Rover) and Goddard (International Space Station).
- (585) 482-0300
- (585) 288-5989
- info@appliedimage.com
- 1653 East Main Street
Rochester, NY 14609
United States of America
-
Product
SINE M-14 Sinusoidal Array
-
The Sinusoidal Array SINE M-14 was designed for various electro-optical applications, particularly where a small array is needed to fit into the frame. It can fit into an 18mm diameter circle or into a standard 35mm motion picture frame.The lines in the SINE M-14 lie perpendicular to the length of the film. In addition, the pattern is available on a wider film (without perforations) cemented between glass (TM-G options) both the .6 (-60) and .8 (-80) modulations.
-
Product
ACCUplace Position Grid
AP-P Series
-
The AP-P is a unique calibration target that is designed to test the position and/or recognition ability of a vision system. The matrix of small scales, precisely positioned in a grid matrix format, makes testing for subject recognition and system positioning simple.The overall target is comprised of a matrix consisting of 6.0mm x 6.0mm square individual components each having a 5.0mm x 5.0mm X & Y Scale with 0.100 divisions. The scale has pitch accuracy of 1μm. The AP-P is available on two standard materials; Chrome on Glass (CG) and Chrome on Opal (OP).
-
Product
SINE Sinusoidal Single Frequency Gratings
-
Our SINE Sinusoidal Single Frequency transmittance patterns have proved to be very useful for specialized MTF Measurement as well as for such applications as moirè contouring. They are made on film base material with a nominal thickness of 0.175mm. This material is polyester and tends to be somewhat birefringent. The harmonic modulation values are generally 3% or less.
-
Product
SINE M-13-60 Sinusoidal Array
-
The Sinusoidal Array SINE M-13-60 is designed to be used for evaluating systems that work in the reflective mode such as scanners, machine vision systems and cameras. It is imaged on Photo Paper in four different sizes getting larger from 1X – 8X. The ½X and 1X slides incorporate the same spatial frequencies. Spatial frequencies for the 2X, 4X and 8X versions are 1/2, 1/4 and 1/8 respectively.
-
Product
SINE M-7 Sinusoidal Array
-
The Sinusoidal Array SINE M-7 has an image size of 22mm x 30mm which makes it small enough to fit into a standard 35mm projection frame. The gray scale is contained in the outer rows. It is made on 35mm perforated film.The TM-G variations are produced on a wider film (without perforations) and cemented between glass. They are available at each modulation (-35, -60, -80).
-
Product
ACCUplace Land Pattern Plate
APLP-1
-
APPLIED IMAGE, in conjunction with Hewlett Packard Corp., has developed a unique, and extremely accurate, pick & place target set designed to check for accuracy and repeatability of your robotic system, quickly and easily.
-
Product
Reticles, Optical Slits, Optical Apertures
-
With over 30 years of experience in the manufacturing of high precision Reticles, Slits, Apertures, and Pinholes, APPLIED IMAGE has gained a reputation for delivering precise and accurate parts. We have supplied thousands of these parts to be used in Day/Night Sights, Binoculars, Targeting Systems, Telescopes, Tank Sights, Microscopes, and many other Bore-Sight devices.
-
Product
ACCUplace BullsEye /Recognition Grid
AP-B Series
-
A unique concept in imaging calibration technology, The ACCUplace Bulls Eye / Recognition Grid allows the end user to calibrate magnification at multiple power levels, as well as test the system’s ability to recognize and locate distinctive shapes within shapes by focusing on the concentric circles.Each Bulls Eye / Recognition Grid target has individual patterns consisting of 5 concentric circles with 0.50mm line width and 0.50mm spacing between circles (10mm Pitch) with a 0.100mm center dot. In addition, each row and column is labeled with X & Y coordinates. The AP-B series is offered on four standard substrates; Chrome on Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
Product
Stage Micrometer Measuring Scales
-
The SM Series of Stage Micrometer Calibration Standards is ideally suited for calibrating optical, imaging, video as well as reticle based measurement systems. Designed for ease of use and manufactured for durability, the SM Series has both English and Metric scales in one or two axis configurations. Our SM series covers a range of low to high power systems, and can always be custom manufactured to perfectly fit your needs.
-
Product
ISO Test Charts
-
ISO has been the governing body for Image Quality Testing all over the world. To that end, APPLIED IMAGE is proud to be a participant in assuring that the industry has products that meet or exceed the requirements of ISO. Since ISO covers many levels, we provide test patterns of various types that can be used for Image Capture and Evaluation of Optical and Imaging systems of all types.
-
Product
SINE FBI Charts
-
There are two SINE Sinusoidal arrays designed for FBI applications: the SINE M-13-60-S-RM and the SINE M-13-60-FBI Kit.The SINE M-13-60-S-RM was designed jointly by the Federal Bureau of Investigation, of Washington DC, and MITRE, of Bedford MA. The primary function of this Target is for computing Modulation Transfer Function (MTF) evaluation in live scanner fingerprint systems for conformance to Integrated Automated Fingerprint Identification Systems (AFIS) image quality requirements. The array is on reflective material measuring 16mm x 16mm with sinusoidal arrays ranging in frequency from 1.0 to 10.0 cycles per mm; with nominal modulation of the sinusoidal areas at 60%. The top and bottom rows are density scales, from 0.20 to 1.20 densities.The SINE M-13-60-FBI Kit consist of two individual components, the SINE M-13-60-1X-RM and the RR1-N-RM Ronchi Ruling grating.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Custom Barcodes
-
Verifier and scanner manufacturers often require custom barcodes for product evaluation, calibration, and quality control. Whether it’s a single code or a composite sheet of multiple codes, symbologies, minimum x dimension, etc., APPLIED IMAGE produces these custom, photo-composed standards to meet the needs of our global base of customers using our proprietary ACCUedge® technology.
-
Product
USAF Targets
-
These targets conform to MIL-STD-150A. Frequencies change by the 6th root of 2. This target is also available in custom sizes and contrasts. This test target meets requirements as specified in MIL-STD-150A for resolving power tests. The target consists of a series of Elements having two sets of lines at right angles. Each set of lines consists of three lines separated by spaces equal to the line width. Each bar has a length to width ratio of 5:1. (Line width is equal to one half of line pitch, which is the inverse of line frequency.) Elements are arranged in groups of six each and Groups are arranged in pairs. Even numbered Groups occupy the left side and bottom right corner and contain a square feature having and edge length equal to the line length of Element 2 in that group. Odd numbered Groups occupy the top right corner and side. Groups and Elements are labeled and differentiated by numbering adjacent to their features. Frequencies in cycles/mm (c/mm) increase between each Element by the sixth root of two (approximately 12.25% per step). The general formula for the line frequency of any target Element can be expressed as 2Group+(Element-1)/6.
-
Product
Conformance Calibration Standard Test Card for GS1-DataBar Symbol Verifiers
AI-CCS-DATABAR
-
This test card is ideal for testing verifiers, scanners, and other GS1-DataBar barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.