Traffic Simulators
simulate communications over a network.
-
product
API Testing with LoadView
Simulate 1,000s of users hitting your API every second to generate 100,000+ calls to your server per load testing session.Define your API tests to simulate traffic at the pace you need by implementing a load curve that increases the number of simultaneous users as necessary to properly test your system.Gather performance metrics consisting of the response times of each session and validation that the API returns the expected results in each response.Visualize how the average response time is affected as you increase the number of simultaneous users.Examine individual test sessions to see error codes and utilize additional troubleshooting tools such as traceroutes, waterfall charts and a copy of the server response.
-
product
Fibre Channel Modules
AIM’s Fibre Channel test, simulation and analysis modules use our field proven Common Core hardware design giving you the best performance, best feature set and highest functional integration on the market. The use of SoC (System on Chip) based core designs with one dual core RISC processor per port, massive and scalable DDR3 memory and IRIG-B time encoder/decoder functions are standard. The new ultra high performance intelligent 4-lane PCIe 2.0 interface modules offer 2 ports with full function test, simulation, monitoring and analyzer functions for Fibre Channel networks. The dual core processor provides onboard processing and data transfer capabilities for the most demanding Fibre Channel applications including upper layer protocol support done on board level. Large and high data throughput DDR3 RAM is accessible for the onboard processor as is a high performance FPGA implementing the customized Fibre Channel interfaces enabling the board to analyze incoming and modify outgoing data in real time. Each module provides 2 Fibre Channel compliant full duplex ports, implementing the full link level services. SFP cages make it suitable for different media types as optical or electrical network technologies. Ports operate either in Traffic Simulator or Analyzer/Monitor mode with support for port related Frame Statistics. Sophisticated packet capturing mechanism and monitoring features are complimented with powerful triggering and filtering capabilities.
-
product
Enterprise-Scale Application and Security Testing
PerfectStorm ONE 10GE/40GE Appliance
Keysight Network Applications and Security
Building upon the terabit-scale PerfectStorm platform, PerfectStorm ONE™ appliances offers enterprises, service providers, and technology vendors a revolutionary solution for generating stateful applications and malicious traffic, simulating millions of real-world end-user environments to test and validate infrastructure, a single device, or an entire system.
-
product
ACARS CMU Simulator
Square Peg Communications Inc.
The SPCI CMU Simulator replaces the ACARS Communications Management Unit for end-to-end testing of the ACARS system. It communicates with an Inmarsat Classic Aero or SB-Safety Satellite Data Unit (SDU) via ARINC-429 to generate and receive ACARS traffic. The CMU Simulator is implemented as a Physical Layer Tester script, and can run on either a BPLT or a GDU. In addition, it can run on a standard PC using a special version of the GDU or BPLT software. In all cases, a suitable ARINC-429 interface must be present.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel With V/I Readback
41-752A-011
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI RTD Simulator Module, 4 Channel, PT1000
40-263-503
The 40-263-503 is a 4-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module, 12 Channel, PT100
40-263-301
The 40-263-301 is a 12-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
UV Range Simulators
Textron Systems' operational range systems deliver the same rich, high-fidelity environment enjoyed in systems integration laboratories and on flight lines to training ranges for seamless interoperability and maximized training outcomes. Our modular design allows easy configuration of a multispectral system for training and test to support advanced sensor fusion.
-
product
Dual Port Simulator Fiber Channel PCI-X Module
PCI-X-FC4 Simulyzer
The modules are available as a single-function board - for analysis or for simulation / data generation - but also as a full-function board for simultaneous analysis and simulation. By simply upgrading the firmware / software, a single function board can become a full function board without having to purchase new hardware.
-
product
PXI Battery Simulator Module
41-751-001
The 41-751 is a low power battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
product
PXI/PXIe Resolver Simulator Module, 4-Banks
43-670-201-AABBCC
The 41/43-670-201 is ideal for the simulation of Resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire resolver.
-
product
PXI/PXIe Resolver Simulator Module, 4-Banks
41-670-201-AABBCC
The 41/43-670-201 is ideal for the simulation of Resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire resolver.
-
product
PXI RTD Simulator Module, 8 Channel, PT500
40-263-402
The 40-263-402 is an 8-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
Thermocouple Simulator Module for SLSC
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
product
PXI RTD Simulator Module 18 Channel PT100
40-262-001
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
product
4, 8, 16 And 32 Channels ARINC429 Test & Simulation Module CompactPCI-Express/PXI-Express (3U)
ACE429-3U-x
4, 8, 16 and 32 channels ARINC429 Test & Simulation module for CompactPCI-Express/PXI-Express (3U).
-
product
Photovoltaic Array Simulator
PV8900 Series
Keysight’s photovoltaic (PV) simulator includes the hardware and software to test a single maximum power point tracking (MPPT) inverter accurately. Test PV voltages up to 2000 V and 60 A with a single supply. DG9000 Series software licenses are available to test string inverter with 4-, 8-, or 12-MPPT channels. Most string inverter solutions test one MPPT channel at a time — leading to test inaccuracies. Keysight's DG9000 advanced PV inverter software can test up to 12 MPPT channels simultaneously.
-
product
PXI RTD Simulator Module, 20 Channel, PT100
40-263-101
The 40-263-101 is a 20-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI/PXIe LVDT/RVDT Simulator Module, 4-Banks
41-670-101-AABBCC
The 41/43-670-101 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
Regenerative Grid Simulator
61800 series
Market demand for Distributed Resource (DR) products such as PV inverters and wind energy systems is steadily growing as the world strives for clean renewable energy sources. This demand has created a need for rigorous regulation testing to standards such IEEE 1547 / IEC 61000-3-15 / IEC 62116 ensuring proper and safe operation of on-grid products. It has become critical to manufacturers to conduct these tests to prove compliance and to relieve product liability concerns. Chroma’s new 61800 family of Grid Simulators has been designed to fulfill these test requirements by providing a full 4 quadrant, fully regenerative, grid simulator with advanced features for compliance, safety and product verification testing.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 4-Banks
41-670-001-AABBCC
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
product
Single Stream STANAG3910 Electrica lTest And Simulation Module – Rafale – for PCI
APXX3910-EN
Single Stream STANAG3910 Test and Simulation Module – Rafale – for PCI with 1 dual redundant HS/LS channel and onboard Electrical Front End. The APXX3910-EN is a functional replacement for model APX3910-EN.
-
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 2-Banks
41-670-003-AABBCC
The 41/43-670-003 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
product
PXI/PXIe Battery Simulator Module, 4-Channel, 1 kV Isolation
41-752A-102
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, V/I Readback, 750 V Isolation
43-752A-011
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, Simplified Current Sink, 750 V Isolation
43-752A-901
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI/PXIe Battery Simulator Module, 2-Channel
41-752A-003
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
ARINC825 (CAN Bus) Test & Simulation Module for PCIe
ACPe825-x
ARINC825 (CAN bus) Test & Simulation module for PCIe with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACP825 PCIe card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
product
PXI RTD Simulator Module 6-Channel PT1000
40-262-102
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.




























