Impedance Testers
See Also: Loop Impedance Test, Impedance Analyzers
-
Product
Electrical Impedance Tomography
-
Electrical Impedance Tomography (EIT) is an imaging technique that visualizes conductivity or impedance distributions both in 2D and in 3D. Sciospec is partnering with world leading scientists in the field to deliver solutions that enable using EIT both in research and in practical applications.
-
Product
Impedance Meter
ZM-100
-
Monacor International GmbH & Co.
Impedance meter for measuring the impedance (Z) of individual loudspeakers and loudspeaker lines.
-
Product
Impedance Matching Pads
-
Surface mount and coaxial 50 Ohm / 75 Ohm impedance matching pads for CATV systems, broadband networks, test setups and more!
-
Product
Precision Impedance Analyzer (10Hz to 130MHz)
ST2851
-
ST2851 series precision impedance analyzer is a new generation impedance test instrument by adopting the current international advanced automatic balance bridge principle. It is based on Windows10 operating system, which realizes a fully computerized operation interface, making the measurement more intelligent and easier.ST2851 series impedance analyzer surpasses the 120MHz frequency bottleneck of similar foreign instruments, and solves the defect that it can only be analyzed but cannot be tested independently. At the same time, it adopts two interfaces of single test and analysis to make the test easier.
-
Product
High Impedance Active Probes
12C
-
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
Product
Impedance Analyzers
MTZ-35.
-
An impedance analyzer with the features and specifications necessary for working on a the broad range of applications in the field of materials research.
-
Product
Impedance Measurement
CITS880s
-
Finer geometries and thinner copper can present a challenge for fabricators measuring impedance on leading edge PCBs. The CITS880s answers that challenge with the introduction of Launch Point Extrapolation (LPE). LPE extrapolates the TDR response back to a point close to the start of the transmission line effectively allowing to users more accurately to measure the instantaneous or incident impedance of the line.
-
Product
Impedance Stabilization Networks
ISN
-
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.
-
Product
Manual Tuners / Impedance Tuners
-
Maury manual tuners are based on precision slide screw technology that utilizes broadband slab line transmission structure and passive probes to create impedances for devices. The probes are designed to be very close to onequarter wavelength in the linear dimension at the mid-band of each range. Since each tuner has two probes, this results in improved matching characteristics for each unit. Another key feature of this series of tuners is the inclusion of a LCD position readout of the carriage position on those units operating below 18 GHz. Higher frequency tuners utilize a micrometer carriage drive. The positional repeatability and high matching range of these tuners make them ideally suited for use as a variable impedance source in applications like device characterization. Such measurements depend upon the ability of the tuner to establish impedances out near the edge of the Smith chart and to reproduce the electrical characteristics as a function of mechanical position. The tuners in this series are also easy to use due to the nearly independent electrical results of the mechanical motions. The depth of penetration of the probe into the transmission line determines the magnitude of the reflection, while the position of the probe along the line determines the phase. While there is some interaction, the effects are almost independent of each other. https://www.maurymw.com/images/mw-rf/mst982e35.jpg
-
Product
Impedance Analyser Frequency Response Analyser
C60
-
The C60 investigates the opaque world of analog networks. The unit operates in two test modes. It can measure the frequency response of a two port system producing a gain/loss and phase graph. It can also measure the reactive response of a two terminal network producing an impedance/admittance and phase graph. Electronic, electrical, electro-acoustic and other networks can be tested with sine wave excitation and the results displayed on a PC.
-
Product
High Impedance Probes
-
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
Product
Impedance Analyzer 1MHz-20Hz
IA1000
-
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
Product
Impedance Analyzer
-
When used together with the PSM range of frequency response analyzers, the N4L impedance analysis interfaces provide a measurement solution to many impedance analysis applications. The most appropriate interface for a specific application will depend upon the nominal impedance of the sample or device being tested and the frequency of measurement and N4L will be happy to discuss the optimum soution to any application. Reasons to choose an N4L Impedance Analyzer
-
Product
High Impedance Differential Module
HID
-
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
Product
High Impedance Active Probes
7
-
Designed as a companion probe to Models 12C and 18C for driving integrated circuit lines so the Model 12C and 18C can be used to measure the response of adjacent nodes. The Model 7 consists of a flexible 6 foot, 50 ohm coaxial cable accurately terminated to 50 ohms in order to avoid undesirable reflections. A special miniature connector receives replacement coaxial probe tips that provide a shielded environment to within 3 mm of the fine tungsten probe point, thus minimizing capacitive coupling to other parts of the circuit. The replaceable coaxial probe tips are offered in various point sizes and can also be bent to any shape in order to accommodate a variety of probing geometries.
-
Product
Overhead Line & Cable Impedance Test Sets
-
T&R Test Equipment Overhead Line & Cable Impedance Test Sets
-
Product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
-
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
Product
Short Circuit Loop Impedance Meter
AMZC-306
-
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more
-
Product
Antenna Impedance Analyzer
TZ-900 AntennaSmith
-
Analysis Parameters: SWR, Complex Impedance, R+jX, reflection coefficient, Smith Chart. 0.2 - 55 MHz • SWR
-
Product
Impedance Matching Pads
-
These impedance matching pads are resistive networks that can be used to match 2 devices with different nominal impedances. The resistive network used in these impedance matching pads has a 5.7db theoritical insertion loss; true loss is 5.7db plus the normal other losses. common use is to connect 50 ohm sma's to 75 ohm f's. There are also 75 ohm versons of N's, BNC's, & SMA's.
-
Product
LCR Meters And Impedance Measurement Products
-
Complete impedance measurement solutions to meet your needs from LCR to impedance meters, plus test accessories for various R&D and manufacturing applications.
-
Product
Line Impedance Stablisation Networks (LISN)
Emissions
-
All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. All bar the heavy current LISNs are constructed in a flanged aluminium enclosure that can be bolted directly down to a ground plane (as required by standards). The underside of the enclosure is left unpainted to ensure good conductivity with the plane. The 16A and military/automotive LISNs have an RF output for each line, thus allowing parallel measurements of the emissions. This facilitates measurement of common mode and differential mode components of the emissions if required.
-
Product
Insulation Tester
61-797
-
*Checks new installation for damaged insulation*Checks existing installations and motor windings for breakdown in insulation*2-year warranty
-
Product
High Impedance Active Probes
18C & 19C
-
High impedance probes, PICOPROBE® MODEL 18C and MODEL 19C, combine the most advanced MOS and bipolar technologies with special, low capacitance packaging techniques to achieve truly remarkable electronic measurement capabilities. While being manufactured each instrument is individually optimized for the best possible performance. The extremely low input capacitance, high input impedance, and almost negligible input leakage current permits the direct probing of even the most sensitive MOS dynamic nodes. At the same time, the full dc capability of this Picoprobe coupled with the high speed capability permits the full characterization of circuits.
-
Product
Headlight Tester
LITE 3
-
Maschinenbau Haldenwang GmbH & Co. KG.
Quick and accurate testing of the headlight setting Operator-friendly menu guidance using LCD graphic display Measurement recording with CMOS camera technology "Stand alone" version with PC connection Result evaluation with integrated control electronic Easy headlight adjustment with „acoustic setting mode"
-
Product
Puncture Testers
-
Mechanical puncture testers check the puncture resistance or hardness of materials like dry wall, foam boards, cardboard, etc. They are ideal for handheld penetration tests or mounting to a test stand and intrinsically safe in hazardous environments. An optional handle is available.
-
Product
Compression Tester
-
Guangzhou Biaoji Packaging Equipment Co., Ltd.
Compression tester is used to test the compression resistance of packaging bag.
-
Product
Moisture Testers
-
Wuxi IMHOO Technology Co., Ltd.
Used to measure the percentage of water in materials like wood, drywall, concrete, and soil.
-
Product
High Impedance Busbar Differential Relay
MIB
-
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
Product
Precision Impedance Analyzer (20Hz to 10MHz)
ST2839
-
ST2839 series precision impedance analyzer is a new generation impedance test instrument by adopting the current international advanced automatic balance bridge principle. Its basic accuracy of 0.05%, the fastest test speed of 5.6ms, the frequency range of 20Hz-10MHz, and the impedance test range of up to 1GΩ can meet the testing requirements of components and materials, especially for low-loss (D) capacitors and high-quality Measurement of Factor (Q) Inductors. The four-terminal pair port configuration method can effectively eliminate the influence of the electromagnetic coupling of the test line, and expand the lower limit of the low-impedance test capability ten times lower than that of the conventional five-terminal configuration instrument.





























