Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
1mm Verification Kit
85059V
-
The Keysight 85059V is a 1.0 mm verification kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. This includes a set of standards with known characteristics, traceable to primary standards in the Keysight Technologies calibration lab. This verification kit is used to verify the measurement calibration and also to verify that the PNA/PNA-X based millimeter-wave system is operating within its specifications. The 85059V with 85059B 1 mm calibration kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Waterproof Portable pH Meter
CyberScan pH 310
-
Multi-Point Push-button Calibration (up to 5/6 points) with Auto-Buffer Recognition - choice of USA, NIST or DIN buffer standards for quick calibration with no calibration mistakes
-
Product
IC Design & Verification
-
Mentor Graphics provides best-in-class products for IC design. Calibre for physical verification, extraction, resolution enhancement and mask data preparation, ADVance MS for analog/mixed-signal simulation and an integrated tool flow for custom IC design
-
Product
Geo Analyzer
ElvaX Geo
-
Instant on-site elemental analysis is one of the necessities of the modern mining industry. ElvaX Geo offers you accurate data and ease of operation during geo exploration or quality assurance. The instrument is designed specifically for long non-stop convenient operation. The unique 800 mm2 analytical spot analysis increases averaging of inhomogeneous samples. A composite pole helps you keep a comfortable body position during operation and enables you to analyze hard-toreach places. This form factor allows for uninterrupted measurement during slow walking while measurement results are communicated to the operator through headphones. ElvaX Geo is operated through a PDA in a protective enclosure, which can be put underneath outer garment in case of extreme climatic conditions. The Li-Ion Battery can be hidden as well. ElvaX Geo software uses both the Fundamental Parameters and the Empirical Calibration Methods. Fundamental parameters analysis of unknown samples without empirical calibration is remarkably accurate. However every instrument is calibrated for the basic mineral types with NIST or NIST traceable samples. ElvaX Geo demonstrates excellent limits of detection and repeatability.
-
Product
Optical Power Meter
TL-520
-
TL520 Mini-Designed Optical Power Meter is a self-developed test instrument which is widely used for installation, operation and maintenance of fiber-optic network. TL520 can test optical power within the range of 800~1700nm wave length. There are 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, six calibrated wavelength.
-
Product
Meter With pH Electrode, ATC Probe
pH 2700
-
Oversize screen with large fonts yet compact – the new Eutech pH 2700 offers an easy to read screen that says more! View pH or ORP readings, with temperature, electrode status, calibration points, date and time all at once!
-
Product
Calibration Kit
F7511
-
F7511 Calibration Kit, Frequency Range: up to 3 GHz, Impedance: 75 Ohm, Connector type: F-type
-
Product
Color and Monochrome Camera
DP74
-
The DP74 color camera for fluorescence not only advances the speed and ease with which you can obtain detailed, accurate images but also introduces for the first time the concept of Intelligent Imaging. With Intelligent Imaging, the camera analyzes the live image and automatically applies its technology to reduce processing time and produce quality images of even dim and challenging samples. Furthermore the camera can follow your stage movements to create in real-time a panoramic image with mapped zoom-outs, a great time saver for documenting your sample. The DP74’s wide field of view and unsurpassed live speed provide an on-screen experience closely matching the traditional ocular view, thanks to its expertly calibrated colors. Maximize your investment return on a shared laboratory instrument with the camera’s top resolution of 20.7 megapixels and the capability to work with brightfield and fluorescent samples alike. These features are compatible with any microscope, whether manual or motorized, making the DP74 a perfect solution for a smarter and faster imaging workflow.
-
Product
Coaxial Termination, DC to 3 GHz, 75 Ohms
909E
-
The Keysight 909E is a precision, low-reflection dc to 3 GHz load for terminating a 75-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard.
-
Product
Smaet LDV III
-
A Laser Doppler Velocimeter (LDV) measures fluid velocity by utilizing coherence of laser light. It detects the Doppler shift frequency of the scattering light of particles in the fluid and calculates the velocity of the particles (fluid). With a LDV system, non-intrusive measurements without disturbing the measuring object, liquid or gas flow, are achieved. No calibration is necessary and reverse flow measurements at a high resolution is also possible. The LDV system provides the absolute value of the flow velocity with accuracy.
-
Product
PCI Strain Gauge Simulator Card, 6-Channel, 2k
50-265-306
-
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
Toxic Gas Detector
SMC 5100-XX-IT
-
The SMC 5100-XX-IT gas detector monitors toxic gases such as Hydrogen Sulfide, Carbon Monoxide, Nitrogen Dioxide, Ammonia, Oxygen Deficiency, and others. The detector requires calibration only every six months, cutting operating costs and time.
-
Product
Crossover Calibrator
CC-1
-
The purpose of this tool is to enable the installer to set the crossover frequency of an electronic crossover to the desired frequency, accurately and quickly. It can also be useful for matching gains on multiple amplifier competition type systems.
-
Product
VNA Calibration Kits
-
Vector Network Analyzers are commonly used to accurately determine the RF Characteristics of microwave components. Accurate Testing of microwave circuits means eliminating measurement errors and ensuring repeatable results. This is only possible when the network analyzers can be calibrated with known and true calibration standards.
-
Product
Pocket Conductivity Testers
-
Labodam pocket conductivity testers are equipped with platinum sensors and 1 point brush calibration system. These easy to use pocket conductivity meters come with waterproof design features for protection against harsh conditions. The conductivity meters can be used for measuring the conductivity of drinking water, waste water, brine water, and liquids with high, low conductivity.
-
Product
Calibration & Demag.
Model 8515-D
-
The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.
-
Product
Conductivity and Temperature Water Pocket Meter
LAQUAtwin EC-22
-
The only pocket meter that directly measures conductivity in 0.12ml sample. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.
-
Product
Calibration Services
-
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
Product
4 2/3 Digital Resistance Meter
CS2-RS
-
CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
Product
Digital "A" Flow Controller for High Flow
HFM-D-306A / HFC-D-308A
-
Mass flow techniques provide reliable, repeatable and accurate gas flow rate measurements.HFM-D-306A/HFC-D-308A mass flow instruments have flow ranges from 0-2500 slm to 0-10000 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
Product
Individual UPC Bar Code Standards
-
The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)
-
Product
PC based USB Real Time Analyzer
-
1) Measurement microphone and its accessories (a windshield and a microphone clip)2) XLR-to-USB Converter3) USB cable (1.5 m) 4) CD (contains the copy-protected Multi-Instrument Software) 5) USB hardkey (contains a Multi-Instrument Standard License)6) Audio Test CD (contains a list of audio test tones and noises) (AudioTestCD.zip or AudioTestCD.rar)7) 1/8” TRS cable (1.8m) 8) Black Soft Pouch Case 9) Individual Sound Level Calibration Data 10) Individual Microphone Calibration Data (only provided in RTA-168B)11) A small microphone stand
-
Product
Automated Fibre Loss Test Set
LTS-1500
-
The LTS-1500 is a small, rugged automated fiber optic loss test set that characterises singlemode fiber links at wavelengths of 1310, 1490 and 1550 nm. It is comprised of a sensitive InGaAs based optical power meter calibrated at six wavelengths with better than -75 dBm noise level plus a stabilised laser light source with up to three selectable wavelengths.
-
Product
Radon Professional Monitoring
-
Our dedicated range of products and accessories has been especially designed to fit these needs and to provide accuracy in the following application fields: Short and long-term monitoring of radon concentration indoor and outdoor, water and soil gas analysis Radon surveillance and mitigation at workplaces (according to valid radiation protection regulations) Geological survey, e.g. vulcano watching, earthquake surveillanceAlphaGUARD products reputation is worldwide recognized, as a reference device for calibration for active and passive radon detectors.
-
Product
HUM DETECTOR (DEMODULATOR)
HD-500
-
Matrix Test Equipment Incorporated
The MATRIX Model HD-500 is a detector-amplifier designed to demodulate the low frequency amplitude modulations on any RF carrier over the range of 5 to 1500 MHz. These modulations are usually the undesirable result of the 50 or 60 Hz power source and are not necessarily sinusoidal. The unit is calibrated to the SCTE definition of hum modulation, which is the ratio of the peak-to-peak hum modulation to the peak of the carrier.
-
Product
PH And Temperature Pen
Ultrapen™ PT2
-
This instrument is designed to be extremely accurate, fast and simple to use in diverse water quality applications. Advanced features include automatic temperature compensation; highly stable microprocessor-based circuitry; user-intuitive design; and waterproof housing. A true one-handed instrument, the PT2 is easy to calibrate and easy to use. To take a measurement, you simply push a button then dip the pen in solution. Results display in seconds.
-
Product
Meter With 4-Cell Conductivity/ATC Probe
CON 2700
-
Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once.
-
Product
10 MHz To 67 GHz LAN Thermal Vacuum Compliance Power Sensor
L2067XT
-
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
Product
Vehicle Standard Interface
VSI-2534
-
Vehicle reprogramming tools are becoming an essential auto diagnostic tool in automotive repair shops. Technicians often come across OEM Technical Service Bulletins that require them to reprogram the vehicle with the latest OEM calibration files in order to diagnose and repair car problems such as check engine light, gas mileage, false DTCS, shifting, hesitation, rough idle, emissions quality, ABS, performance, and more.





























