Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
10 MHz To 54 GHz LAN Thermal Vacuum Compliance Power Sensor
L2066XT
-
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
Product
EZ-TorQ III Torque Analyzer
-
The EZ-TorQ III makes torque control easier and more available across every aspect of the line from the calibration lab to the assembly station. Highly portable and user friendly, this battery powered torque validation hub can be easily carried around the assembly line to spot check tools as part of a QA program or used at assembly stations for quick and easy torque tool validation and calibration. The new smart phone like touch-screen interface breaks down barriers and ensures quick and easy validation of different ranges as needed.
-
Product
Manual Pressure Calibration
-
Manual pressure calibrators are a fast and practical solution for generating and adjusting pressure while calibrating analog pressure gauges and other sensors. They are convenient for mobile calibration applications. Fluke Calibration's pressure monitors combine very high accuracy measurement capability and a variety of unique features in compact and easy to use packages, either standalone or integrated with a calibrator. Models include E-DWT DHI electronic deadweight testers; RPM4 DHI pressure monitors and 7050 Ruska pressure monitors.
-
Product
MAX PH/ORP/Temp Bench Meter
MW150
-
The Milwaukee MW150 MAX 3-in-1 pH/OPR/Temp. Bench Meter has won fans around the world with its reliable, fast, simple operation as well as a tough, sleek, lightweight design with a small lab space footprint. It is accurate to ± 0.01 pH with automatic or manual temperature compensation, and built in dedicated GLP key. In addition, up to 3-point automatic calibration and 7 selectable buffer standards makes the MW150 MAX ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
Product
Concrete Moisture Meter
7410
-
The electrodes transmit parallel low frequency signals, calibrated to give average moisture content by comparing the change in impedance between damp and acceptably dry concrete.Calibrated ready for use on concreteInstant readings on a clear, easy to read scaleFully portable, battery operated and non-destructive
-
Product
MultiFunction Calibration
-
Omega offers a large selection of configurable Multi-Channel Meters that accept a wide variety of input signals for scanning, displaying, and logging measured data from multiple sensors.
-
Product
Web Sensor
T7511-2
-
Web Sensor with relative humidity and temperature probe on the cable. Built-in atmospheric pressure sensor.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
Product
Waveguide Cassette
-
Waveguide cassettes provide easy way for the network analyzer calibration and material properties as dielectric permittivity or (and) magnetic permeability measurements. By changing insertion sections, it is possible to calibrate "Short" and "Thru". Optional cassettes with quarter wave "short" inserters are available. Using this waveguide cassette, it is possible to do vector network analyzer calibration or additional scalar network analyzer calibration. Insertable sample holders supports two measurement methods: the rod in the centre of the waveguide and filled waveguide cross-section.
-
Product
50 GHz Test Port Extension Cables
-
Spanawave's test port extension cables are the perfect alternative to over-priced models from other manufacturers. These test cables provide the utmost precision in vector measurements in the lab and during calibrations. Besides the electrical performance, these VNA cables are rugged and feature a lightweight armor to insure consistent performance over time. A wide variety of connectors are available including the precision "NMD" or "port ruggedized" connectors, which mate directly to the VNA port. Custom lengths and configurations are available. Please contact us for application help and pricing.
-
Product
Multi-Cal Benchtop Calibrator
MC6
-
Model MC6 Multi-Cal Benchtop Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility
-
Product
Manual Oscillators
MOS-01, -01A
-
The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.
-
Product
Model AM-IIIB: Paper Moisture Meter
AM-31B3
-
Portable digital paper moisture meter to measure single sheets. Permits instant and non-destructive moisture detection measurement on all types of paper and paperboard. Pre-programmed with 11 different Calibration Curved with option to select a field. Fast and accurate. Uses Radio Frequency to minimize effects of pH and temperature variations
-
Product
Rack Mount Thermometer Hygrometer
H3531R-4
-
Sensor H3531R is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
Product
MIPI Receiver Test Solution
M8085A
-
The M8085A is a software plug-in for M8070A Bit Error Ratio Test system software within the M8000 series of BER test solutions. The M8085A software plug-in controls either the M8190A or the M8195A Arbitrary Waveform Generators to create C-PHY or D-PHY standard compliant test signals. In addition it provides routines for calibration of all signal parameters and for all tests specified in the applicable Conformance Test Suite. Together with the additional available DUT control interface it is possible to read the BER of the receiver under test from the M8070A software and display the BER dependency from test parameters within the M8070A user interface.
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Large Calibre Barrel Bore Gauge System
BG20
-
Aeronautical & General Instruments Ltd.
The BG20 has been specifically designed to modernise and improve the inspection routines of large calibre barrels. A two-point measuring head is supported in the barrel or chamber by a clear disk which facilitates the angular alignment of the head and the location of a suspected defect.
-
Product
Shield Level / Pathloss Equipment
PathTrax
-
Identical in form factor to the PAMS and PAMS-C, PathTrax provides an optimum solution for site surveys. Once the receiver is calibrated with the transmitter, the receiver measures path loss directly. PathTrax systems are available to cover several frequency bands each 75MHz wide, centered on 838 MHz, 860 MHz and 915 MHz. A PathTrax centered at 500MHz, covering 25MHz of bandwidth is also available.
-
Product
Frequency Sources
-
PMI offers a full line of Digitally Controlled Oscillators (DTOs), Dielectric Resonator Oscillators (DROs), Voltage Controlled Oscillators (VCOs) and Frequency Synthesizers covering various frequencies in the 50 MHz to 40 GHz range. All models are designed to withstand stringent military ground or airborne environments. These models use the latest internal digital calibration techniques such that frequency drift over the operating temperature range is minimal. All units offer fast switching speeds and stable frequency outputs with low phase noise. If you do not see exactly what you need, please e-mail your requirement to sales@pmi-rf.com so we can propose an instant solution.
-
Product
Surface Calibrators
-
Electronic Development Labs, Inc.
A software-driven process for gaming mice that optimizes the sensor to a specific surface's texture, reflectivity, and weave.
-
Product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
-
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Strip Tension Measurement
-
ABB’s strip tension system is the perfect choice for measuring strip tension in hot rolling, cold rolling and process lines.Accurate strip tension measurement is a prerequisite for keeping the strip tension constant within the desired range, during both acceleration and deceleration. This allows for optimal strip quality, increasing process uptime and preventing strip breaks. The system is proven to be exceptionally robust and resilient to high forces as well as aggressive mill agents. The load cells are calibration free, can withstand overloads up to 10 times the nominal force, and have an impressive life length. The load cells come in different sizes up to 200 kN.
-
Product
Pressure Fittings
-
AMETEK Sensors, Test & Calibration
Our CPF Fittings & Hose are a new line of quick-test pressure fittings for calibration & test applications - designed with an emphasis on safety. Crystal Pressure Fittings (CPF) perform up to 10 000 psi / 1000 bar, and feature a safety weep hole to alert you before you accidently disconnect from a pressurized system. It can also be used as a bleed point. CPF fittings seals two ways: use fingers for an o-ring seal or use a wrench for a metal to metal cone seal (good to -40°C).
-
Product
Environmental Dataloggers
-
Transcat is your premier provider of environmental dataloggers. We carry an extensive inventory of test & measurement equipment, with over 3000 products available for same-day shipping. For many instruments, new instrument calibration is also available, ensuring that your product is tested and ready for use as soon as you get it.
-
Product
Electrical Calibrators
-
An electrical calibrator, or dc calibrator from Fluke Calibration includes many innovative and multi-functional solutions to help laboratories operate efficiently, increase throughput, and comply with today’s quality standards. Versatile models and options provide a wide range of possibilities to match a variety of workloads and budgets. Electrical calibrators include: Multi-product calibrators; multifunction calibrators; oscilloscope calibrators; power calibrators; pressure/temperature calibrators.
-
Product
Universal Transmitter
Ut4623
-
Programmable via detachable Programming Unit (UT4624), process calibration, signal and relay simulation, password protection, errordiagnostics and selection of help text
-
Product
Spectrum Analysis, Up To 70 GHz
S930907B
-
The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.
-
Product
Spectrum Analysis, Up To 13.5 GHz
S930901B
-
The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.
-
Product
1-Port 6 GHz Analyzer
R60
-
R60 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-Port VNA comes with all the features engineers have come to expect included standard in our software.
-
Product
Torque Verification
90229
-
SDI’s 90229 is designed for calibrating tools used to apply torque including electric and pneumatic power tools, torque sensors, hand and click wrenches. The strain gage based reaction torque sensors in the bench-mount housing remain stationary while torque is applied. The housing dis-assembles by removing two snap pins, allowing the user to easily change socket sizes and capacities.