Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
16 Thermocouples/RTD Ch
APCI-3200-16
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel16 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 8 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
Validation Thermocouples
-
Highly accurate temperature sensors used to monitor, map, and verify temperatures in highly regulated environments.
-
Product
Mineral Insulated Thermocouples ANSI
-
Durable Mineral Insulated type thermocouples ANSI to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
Thermocouples
-
Watlow Electric Manufacturing Company
Thermocouples are best suited for high temperatures, extreme environments or applications requiring microscopic size sensors.
-
Product
J-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 2 m
745690-J002
-
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
4 Thermocouples/RTD Ch
APCI-3200-4
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel4 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 2 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
16 Inputs Temperature Data Logger – Thermocouples
HD32.8.16
-
Rugged data logger with 16 inputs for K, J, T, N, R, S, B and E type thermocouple
-
Product
USB Temperature Measurement Bundle
Temperature Input Module
The USB Temperature Measurement Bundle includes a CompactDAQ Chassis with the C Series Temperature Input Module for temperature measurements. The USB Temperature Measurement provides a portable, USB-based sensor measurement system with features such as anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
Product
Thermocouple Contact, Receiver, Constantan, Type T (°C)
610113148
Thermocouple Contact (Receiver)
Primary mating contact 610113149.
-
Product
Push-Button Temperature Transmitter
659
-
Series 659 Push-Button Temperature Transmitters accept thermocouple (J, K, T), RTD (Pt100Ω) or thermistor input and provide a linearized 4 to 20 mA output. The transmitter is quickly ranged and calibrated by using a single on-board switch
-
Product
Configurable Thermocouple Transmitter
HD778TR1
-
Configurable 4...20 mA/20...4 mA 2 wire temperature transmitter for K, J, T, N thermocouples.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30001-K
-
Breakout board for the MAX31855K digital thermocouple interface IC. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header, has a vertical mini thermocouple connector and four mounting holes for standoffs and 4-40 screws.
-
Product
Thermapen
Super-Fast ®
-
The Super-Fast ® Thermapen has been a favorite among restaurant chains, health inspectors and quality managers worldwide. Hundreds of thousands are in use. The clever fold-away probe and the simple pocket design replace more costly and bulky handheld thermometers while using the same professional thermocouple technology. This new generation Thermapen introduces a robust, splash-proof design with molded-in seals to protect the thermometer from wet hands and kitchen splashes.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
782975-01
Temperature Input Module
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
Current Data Logger Two Channels with USB
VA602-A1-A1
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Two tunnel data logger with voltage current temperature (thermocouple) K.J.PT type, with USB, up to 16000 data record point.
-
Product
Temperature Calibrators
-
Highly accurate dry well temperature standards designed for testing and calibrating a broad range of thermometers, temperature sensors, thermocouples, RTDs and temperature switches used in military and industrial applications.
-
Product
Thermocouple
-
This sensor uses a K-type Chromel/Alumel thermocouple and is intended for use in high-temperature, high-vibration environments. Control units and data loggers support K-type thermocouples. The sensor is short and compact to minimise its susceptibility to vibration.
-
Product
Copper, Type T (°C) Contact
-
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
Universal Dual Input Temperature Transmitter
SEM1615
-
The SEM1615 is a universal transmitter that accepts RTD, Thermocouple, Potentiometer or millivolt input signals and converts them to the industry standard (4 to 20) mA transmission signal.
-
Product
PXI Simulation Modules For Sensor Simulation
-
PXI simulation solutions for sensor simulation, including PXI Programmable Resistors—ideal for the simulation of resistive sensors and PXI Thermocouple Simulators—these provide multiple low-voltage sources ideal for simulating the operation of a thermocouple. Take a look below for all of our PXI Simulation Solutions, we also offer some of these in PCI format as well . All of our PXI simulation cards are supplied with comprehensive software drivers for Windows® XP/Vista/7/8, Lab Windows / CVI and LabView. The Pickering IVI drivers also fully support National Instruments' Switch Executive.
-
Product
K-type Thermocouple to Digital Converter
THERMO K click
-
THERMO K click carries the MCP9600 IC from Microchip. Depending on the type of probe it uses the click can measure temperatures from −200 °C to +1372 °C.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
USB-TC01, 1-Channel Temperature Input Device
781314-02
Temperature Input Module
The USB‑TC01 is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take … temperature measurements with your PC. You can connect the USB‑TC01 to any USB port to use your PC as a display and monitor data in real time. The USB‑TC01 is compatible with J, K, R, S, T, N, E, and B thermocouples.
-
Product
Modbus RTU Analog Input Modules
-
The Datexel range of Modbus RTU analog input cards for both RS485 and RS232 with Modbus or ASCII protocol can be combined with the DAT9000 series of Modbus Masters. A choice of input cards or modules are available and have various optional inputs such as Voltage, Current, Thermocouples, RTD, and Resistance. Also a choice of 2, 4, 8 channel options are available. The DAT3011 is a Modbus RTU Slave with 1 selectable universal input (Thermocouples, RTD, mV, RTD's or Resistance), 2 x 4-20mA or 0-10V input and 2 x4-20mA outputs. The DAT3011 also has 3 digital inputs and 3 relay outputs. Each module is isolated from each other and is set up using the DAT3000 software Development package which is free of charge from the Datexel download web page. Datexel also has universal input modules. An 8 channel analog input card is available making the DAT3000 series a very economical solution to large and small scale Data Acquisition. Combining these analog input cards with the analog output cards, the digital input/output cards and the communication devices make Datexel the smart choice where Data Acquisition is required.
-
Product
K-Type Thermocouples Wire, Fiberglass (32deg F to 900deg F) 2 m
745690-K002
-
K-Type Thermocouple, 32°F to 900°F Temperature Sensor - The K-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the K-Type Thermocouple and acquire synchronized temperature data in units of degrees. The K-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Midi Logger
GL240
-
Its compact size contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. The GL240s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage. power ground allowing off-ground measurements using shunts, as well as powered or grounded thermocouples.
-
Product
Thermocouple Switchbox
SWT-2
-
The SWT-2 is a compact, economical switchbox that lets you use two probes in a thermometer which has a single input. SWT-2 was designed with our BAT-12 Thermometer in mind - it is small and easy to carry in the field with a portable BAT-12 - but it also fits any miniature Type T socket. A subminiature connector mates quickly and easily to most Type T thermometers.
-
Product
Configurable System For Temperature Measurement With CAN FD Interface
MU thermocouple1 CAN FD
-
With the MU-Thermocouple1 CAN FD, measurement data from thermocouples are recorded, pre-processed and transmitted with CAN FD. The temperature is measured via 8 connections, which are designed for the temperature measuring ranges J, K or T, depending on the product version. Temperatures can be recorded in Celsius, Fahrenheit or Kelvin and calculated with an individual factor and offset. The measurement data is then transmitted via CAN FD or via classic CAN.





























