Physitemp Instruments
Physitemp Instruments Inc is an electrical/electronic manufacturing company.
- 800.452.8510
973.779.5577 - (973) 779-5954
- 189 Sargeant Avenue
Clifton, NJ 07013
United States of America
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Software
DASYLAB Lite
-
Dasylab lite software for operation of our line of THERMES Data Acquisition Systems. For customers who already have Labview or Dasylab no additional software is necessary. Recommended operating software is Dasylab Lite version 10. The lite version provides all the necessary functions to display and store temperature data in digital and graphical formats in real time. Users may customize the display to suit their particular application. The Dasylab Basic version provides additional features for data manipulation and statistical analysis.
-
Product
Needle Microprobe
MT-29/3HT
-
Fast-response 29 gauge needle probe, (needle length is 3 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Needle Microprobe
MT-23/8HT
-
Fast-response 23 gauge needle probe, (needle length is 8 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Oral Probe
OT-1
-
The OT-1 oral temperature prove for humans is re-useable and has a fast response time.• Fast reading oral use, with accuracy to 0.1°C .• Smooth ball tip. Stainless steel shaft - 3'' long, .050'' diameter. Tip diameter 1/8'', 5 foot lead length. Time constant 0.8 seconds.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
General Purpose Probe
HT-1
-
HT-1 ''Workhorse'' General Purpose Probe - designed for temperature measurement of liquids, gases and semi-solids. Plastic handle with straight 3'' stainless shaft. Not good for surface temperatures. Maximum temperature 400°C, Time constant 0.5 Seconds. 5 foot lead. Not isolated.
-
Product
Vibration Sensitivity Tester
Vibratron II
-
The Vibratron II provides a non-invasive means of measuring the sensitivity to vibration of large nerve fibers of a patient's fingers and toes. Reliable quantitative measurements are achieved with a test that takes only minutes to administer. A two-alternative forced choice procedure is used to determine the degree of sensitivity for comparison to normals.
-
Product
General Purpose Probe
HT-2
-
HT-2 ''Workhorse'' General Purpose Probe - designed for temperature measurement of liquids, gases and semi-solids. Plastic handle with straight 9'' stainless shaft. Not good for surface temperatures. Maximum temperature 400°C, Time constant 0.5 Seconds. 5 foot lead. Not isolated.
-
Product
Gauge Type T Thermocouple Wire
W-TW-26
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Thermocouple Switchbox
SWT-2
-
The SWT-2 is a compact, economical switchbox that lets you use two probes in a thermometer which has a single input. SWT-2 was designed with our BAT-12 Thermometer in mind - it is small and easy to carry in the field with a portable BAT-12 - but it also fits any miniature Type T socket. A subminiature connector mates quickly and easily to most Type T thermometers.















