Filter Results By:
Products
Applications
Manufacturers
Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
product
Thermocouple Calibration Furnace
9118A
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
product
8 Channels Thermocouple, LV A/D
TC1
A thermocouple is a temperature-measuring device typically consisting of two dissimilar conductors that contact each other at one or more spots. It produces a voltage when the temperature of one of the spots differs from the reference temperature on other parts of the circuit. Thermocouple temperature sensors are widely used for measurement and control, and can also convert a temperature gradient into electricity.
-
product
Mezzanine System
5085
ECM P/N 5085 provides two channels of 24 bit A/D conversion suitable for high resolution low speed applications, which include bridge circuits, thermocouples, RTD and voltage measurements. For bridge applications each channel provides a fused +5 Volt or a current source drive.
-
product
Push Button Temperature Transmitter
SEM203/TC
The push button temperature transmitter is a cost effective “smart” in head transmitter that accepts thermocouple temperature sensors.
-
product
Thermocouple Power Sensors
N8481A
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
product
Thermometer REPLACED BY PTM-1
BA T-7001H
In applications where clinical accuracy is not mandatory and cost is a consideration , the BAT-7001H is Physitemp‘s most compact, low cost thermocouple thermometer. The Model BAT-7001H is a high performance, precision hand-held instrument for the measurement of temperature using Type T (copper-constantan) thermocouples. This versatile instrument measures temperature in both °C and °F. The internal memory of the micro-computer stores the minimum and maximum measured temperature for instant recall via the LCD display. BAT-7001H operates on a 9V battery.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
Precision Multi-Functional Manometer
DM 9600
Large 2.8” Color, touch screenTemperature compensated pressure sensorAutomatic zeroing for long-term stabilityTwo (2) K type thermo-couple socketsSimultaneous display of pressure and temperature readings1000 points and 500 sites data memoryMicro SD card slotUSB charging and data downloadHands free operation via magnetic back case20-hour Lithium battery
-
product
Temperature Data Acquistion
THERMES-USB RF
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.
-
product
Thermocouple – Pt100 Thermometer Data Logger
HD2178.2
Thermometer with two inputs, the first for Pt100 sensor for input of probes equipped with SICRAM module, and the second input for thermocouple type K, J, T, E, N
-
product
MSXB 042
MSXB 042
The MSXB 042 Analog Termination Board allows quick and secure connection of discrete wires to the iDSC 1816 Board. MSXB 042 includes locations to install voltage divider resistors and 0-20mA termination resistors, as well as a Cold Junction Compensation (CJC) circuit for thermocouple applications.
-
product
Thermocouple Thermometer – 2 Inputs
HD2128.1
Thermocouple thermometer for probes type K, J, T, R, N, S, B, E, two inputs.
-
product
Gauge Type T Thermocouple Wire
W-TW-30
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
product
K Thermocouple Penetration Probe
TP751
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
product
Exhaust Gas Thermocouples
8TR4C Series
The AMETEK 8TR4C Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested, and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading older style Exhaust Gas Thermocouples.
-
product
K-Type Thermocouple
61-461
*Measures up to 275°*K-type thermocouple plugs into digital multimeter voltage jacks with 61-465 adapter
-
product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30001-JDP
Breakout board for the MAX31855J digital thermocouple interface IC. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header and four mounting holes for standoffs and 4-40 screws. It does not contain a mini thermocouple connector.
-
product
TRMS Multimeter with VFD Mode
FLIR DM66
The DM66 digital multimeter is ideal for automation field service or electronics technicians, providing a comprehensive feature set including low impedance (LoZ) mode, frequency, diode, capacitance, and a Type K thermocouple input for temperature measurement. The multimeter combines rich features, precise measurements, and quality construction into a tool of exceptional value. Easy to use and built to last, the DM66 offers long-term stability for everyday use.
-
product
Thermocouple Thermometer 1 Input
HD2108.1
Thermocouple thermometer with one input for K, J, T, R, N, S, B, E type probes with miniature connector.
-
product
General Purpose Probes
PIT-12
PIT-12 General Purpose Probe for Pressurized Systems - 12'' #304 stainless steel shaft. Diameter is 1/16''. Immersible. Maximum temperature 350°C, Time constant 0.5 Seconds. Shaft Terminated in a sub-miniature Type T Thermocouple plug. 10 foot Sub Miniature Type T extension lead supplied. Not isolated.
-
product
Ball Pressure Test Device
ZBP-T
Made up by the related item according to IEC60695, IEC884-1, GB/T5169.21-2006, GB4706.1-2005, GB2099.1-2008, etc. • R = 2.5mm Pressure: 20N • Base with thermocouple hole • Material: 304 stainless steel
-
product
Gauge Type T Thermocouple Wire
W-TW-44P2
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
product
Power Sensors
8480 Series
The 8480 thermocouple and diode power sensors series provide extraordinary accuracy, stability, and SWR over a wide range of frequencies and power levels.50 dB dynamic range (maximum) over –70 to +44 dBmFrequency range from 100 kHz to 110 GHz (sensor dependent)Accurate average power measurementsRange of thermocouple and diode power sensorsCompatible with EPM, EPM-P, P-series, and E1416A power meters
-
product
DC/10 MHz 67 GHz USB Thermocouple Power Sensor
U8488A
The U8480 series is Keysight's first power sensor with the capability to measure down to DC (only applicable for U8481A/85A). Now, with an expanded frequency range up to 50 and 67 GHz, the U8480 series allows you to make fast and accurate high frequency power measurements in applications ranging from PNA/MXG calibration to high volume manufacturing.
-
product
Portable Multifunctional Paperless Data Logger
S1500 Series
The S1500 series product is a portable paperless data logger. With 8/12/16 channel universal input and thermocouple input function, it can detect thermocouple, RTD, NTC, DC current, DC voltage, frequency, pulse count and other signals at the same time, and the collected data can be vividly displayed through various forms such as digital interface, bar graph interface, real-time curve, etc. The device has rich peripheral interfaces such as USB, TF card, RJ45, WIFI, etc. It is a portable recording instrument with rich functions, highly integrated and intelligent.
-
product
Life Cyclic Durability Testing
Environment Associates can provide everything you need for cyclic durability testing and performance fixturing. Services include mechanical cycling to a position or load, fatigue cycling to a fixed load, rotational torque cycling, and simple push/pull cycling. EA can design your fixture with electro-dynamic, air, or hydraulic assistance to mechanically move your part. All of our fixtures can be manufactured to withstand a wide range of temperature, humidity and vibration inputs. If required, forces can be monitored electronically, using a wide variety of inputs (i.e. strain gages, load cells, rotational transducers, thermocouples, shunts, and more). EA can create holding and check fixtures to perform “pre” and “post” evaluation for dimensional issues that may occur during testing. EA can provide fixtures for single tests run internally for EA test labs and can manufacture fixtures to be purchased directly by the customer for their internal use.
-
product
Dry Block And Bath Calibrators
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
product
Tempical® Tester
H394
Precision Testing For: Thermal Switches, Chromel®-Alumel® Thermocouples, and Continuous-Wire Fire Detection Systems.
-
product
K Thermocouple Penetration Probe
TP776
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
product
Gauge Type T Thermocouple Wire
W-TW-36P2
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.