Partial Discharge Detectors
indicate that localized dielectric breakdown within insulation has occured.
See Also: Partial Discharge Detection, Partial Discharge Calibrators
-
product
Ultrasonic Partial Discharge Detector
HTJF-9002
Wuhan Huatian Electric Power Automation Co., Ltd.
The local discharge signal is received to determine the presence and location of partial discharge.
-
product
Partial Discharge Detector
PXDP-II
The PXDP-II partial discharge meter is a portable device that performs detection and measurement of partial discharges in electrical devices or components. It records partial discharge measurements for analysis and diagnosis through the optional PC software. The PXDP-II can be used in various applications and complies with IEC 60270.
-
product
Superior Handheld Partial Discharge Detector
PDStar
Power Monitoring and Diagnostic Technology Ltd.
PMDT is proud to present one of our latest innovations, the PDStar. It integrates On-Line Partial Discharge (OLPD) testing and Infrared testing for MV and HV equipment, which combines UHF, AE, Ultrasonic, HFCT, TEV, and Infrared testing technologies. It is applicable for online PD testing, as well as abnormal heating and defect detection on all types of substation equipment. PD amplitude, PRPD, PRPS, and infrared spectrums provide critical data for determining the operational condition of electric power equipment. It connects to the PMDTCloud via Wi-Fi/3G/4G to upload test data, download test tasks, and receive diagnostic results in real time. Another uniquely advanced feature of the PDStar is that it integrates with a 100 MSPS (Mega-Samples per Second) HFCT signal processor, which greatly improves the performance for power cable OLPD testing.
-
product
Advanced Handheld Partial Discharge Detector
PDetector
Power Monitoring and Diagnostic Technology Ltd.
The PDetector is an ideal device for On-Line Partial Discharge (OLPD) testing of MV and HV equipment which employs all 5 types of OLPD sensor technology: Ultra-High Frequency (UHF), Acoustic Emissions (AE), Ultrasonic, High Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV). The information from multiple sensors gives the PDetector the versatility to detect all types of PD in all types of substation apparatus. The exact type of PD activity can be determined effectively using multiple on-screen data spectrum analysis.
-
product
Partial Discharge Detector
JFD-2000A
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable for local discharge measurement of all kinds of high voltage electrical equipment and represents the advanced technology of domestic digital local discharge instrument.
-
product
Partial Discharge Detector
PDD 100
The Insulator partial discharge detector is a state-of-the-art technology used by NASA. The Parabolic design of the disc helps to maintain and detect ultrasound from safe distance of 100 Meters. Enhanced ultrasound detection is provided to the device, by combining the features of the already proven Ultra sound sensing technology with extended range and sensing capabilities. A pistol like grip laser pointer, and rifle sights make the Insulator partial discharge detector easy to handle and use.
-
product
Partial-discharge Detection System
GDYT Series
GDYT series include partial discharge power frequency testing transformer(YDTW),partial discharge detector(GDJF2008),Isolation filter frequency doubling power device(GDSF-81G) and power frequency withstand voltage control table(GDYD table).It widely used in electrical manufacturing,power operation departments, research institutes and universities.
-
product
Portable GIS Partial Discharge Detector
JHPD-10
Xiamen Jiahua Electrical Technology Co.,Ltd
JHPD-10 quickly and accurately detects various kinds of partial discharge signals that occur with insulation defects in GIS. Attached on the surface of GIS the detector collects the inside discharge signal of impure gas, suspension potential and solid insulation material. The diagnostic software analyzes the fault character and locates the fault to avoid electricity accident. The device is for daily patrol inspection with high efficiency and easy operation features. Designed with two UHF signal channels, one detects the partial discharge signal; another excludes the disturbance signal like corona discharge in the air and mobile phone communication.
-
product
Expert Partial Discharge Detector
XDP-II™
The well-established XDP-II™ is a battery-operated portable device allowing partial discharge detection and analysis. The data is saved in its internal memory for local or further analysis on the PC-based XDP-SOFT™. Paired with the proper accessories, the XDP-II™ becomes a powerful solution for many applications such as Cable Joints and Elbows, Switchgear, Offline, Acoustic, TEV, Rotating machines, Transformer, etc…
-
product
Partial Discharge Detector
APD-ANNUNCIATOR
The APD-ANNUNCIATOR is a remote partial discharge detection equipment inside any energized cabinet. The probe is installed in the unit under test, instantly reporting its status. This equipment gives a great benefit because it avoids long term damage to the switching equipment.
-
product
Ultrasonic Partial Discharge Detector
HTJF-9003
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for on-line detection and localization of partial discharge in high voltage equipment.
-
product
Partial Discharge Detecting Detectors
Hangzhou Xihu Electronic Institute
Including pulse current PD detecto, high frequency PD detector, transient earth PD detector, ultra high frequency PD detector, and ultrasonic PD detector.
-
product
Partial Discharge Tester
19501-K/19500
Chroma 19501-K partial discharge tester combines hipot test and PD (partial discharge) detector functions in one instrument. The device is capable of a maximum 10kV AC output with leakage current measurement range of 0.01uA and a minimum partial discharge detection of 1pC. The tester is specifically developed to test high voltage semiconductor components and high insulation materials.
-
product
Partial Discharge Test Equipment
Wuhan Huatian Electric Power Automation Co., Ltd.
Partial discharge detectors for high voltage equipment.
-
product
Partial Discharge Meter
APD-LT
The APD-LT equipment is a partial discharge meter in cable accessories (heads or insulators) to improve safety and maintenance. The PD level is presented numerically in the wireless unit.
-
product
Partial Discharge Testing
Weshine Electric Manufacturing Co., Ltd
Using the Windows system operating platform, you can freely choose ellipse, straight line, sine wave display, two-dimensional, three-dimensional graphic analysis mode, spectrum window, Q-V-F three-dimensional characteristic window, and static detailed measurement, observation and analysis of partial discharge pulse of one-cycle test voltage .
-
product
Partial Discharge Measurement System
DAC-6021
DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.
-
product
Partial Discharge Testing Equipment
AR700
PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.
-
product
Online Partial Discharge Monitor
ASM-E
The ASM-E is a permanent partial discharge monitor for cables, switchgear and other high voltage assets.The ASM-E can be configured with up to 128 PD sensor channels. If excessive discharge is detected, the ASM-E raises an alarm that can be configured either locally or by email/SMS. This enables the long-term assessment of plant conditions to be carried out quickly and easily, from any remote computer.
-
product
Partial Discharge Locator
INDIPOINT
Ultrasonic directional microphone for the location of PD The very best maintenance instrument for partial dischargetrapping in medium and high voltage plant.
-
product
Partial discharge measurement with remote wireless reading
PD-LT
The PD-LT allows online partial discharge detection on cable accessories such as cable head for safety and maintenance purposes.The PD-LT indicates the intensity of the partial discharges, converting the electrical charge units (pC) into decibels (dB). Thus the reading is kept as a simple intensity level indication, proportional to the probability of a fault's presence in the tested medium voltage accessory.The remote display gives a dB value of the probe's measurement. The dB value will vary along with the discharges indicators on the PD-LT probe. The measurement range is from 0 to 65dB and the display will show ''OL'' if the reading is over 65dB.
-
product
Partial Discharge Simulation Devices
Hangzhou Xihu Electronic Institute
Simulation device of cable PD faults, simulation device of switchgear PD faults, simulation device of GIS PD faults, simulation device of transformer PD faults.
-
product
PD (Partial Discharge) Tester
Weshine Electric Manufacturing Co., Ltd
Using the Windows system operating platform, you can freely choose ellipse, straight line, sine wave display, two-dimensional, three-dimensional graphic analysis mode, spectrum window, Q-V-F three-dimensional characteristic window, and static detailed measurement, observation and analysis of partial discharge pulse of one-cycle test voltage .
-
product
Partial Discharge Measuring Equipment
Electro Mechanical Enterprises
Partial discharge instruments have two modes of Wide Band and Low Frequency. You can use it for Partial Discharge tests of High-Voltage Equipment, Insulation Materials, High-Frequency Equipment, and Power Semiconductor devices. Partial discharge Measuring Equipment can easily realize the test of Partial discharge on print-circuit boards, connectors, semiconductors, small motors and other insulation materials, to make a judgment on good / bad of them
-
product
Partial Discharge Monitors
Partial Discharge Monitors provide a complete package that includes sensors, cables, data acquisition unit, processing unit (CPU) and software.
-
product
Partial Discharge Meter
TMG
The partial discharge meter TMG was developed for Partial Discharge tests according to VDE 0434 and IEC 60270.
-
product
Portable Partial Discharge/ Detection
AE-150
The AE-150 is designed to detect and localize Partial Discharge activity inside oil-insulated power transformers. This instrument is a powerful diagnostic tool that combines electric and acoustic sensing technologies to perform partial discharge pinpointing.
-
product
Discharging Bars
VARIO discharge products consist of a separate AC power supply for connecting one or more Eltex discharging components. In SINGLE discharging, the voltage generation (power supply ) is integrated in the bar.
-
product
Partial Discharge Tester
19501-K
Chroma Systems Solutions, Inc.
The Chroma 19501-K Partial Discharge Tester is an instrument equipped with AC hipot test and partial discharge detection functions, providing 0.1kV~10kV of AC output, 0.01μA~ 300μA of leakage current, and 1pC~2000pC partial discharge detect ion range for measurement. Chroma 19501-K Partial Discharge Tester is compliant to the IEC60270-1 standard in particular the partial discharge testing requirements for high voltage.