Display Calibrators
reference a test pattern to adjust by.
-
Product
Nonlinear Component Characterization 10 MHz - 110 GHz
S94510B
-
Measure and display the calibrated, vector corrected waveform of the incident, reflected, and transmitted waves of the DUT
-
Product
XYZ Color Sensor
AS7261
-
Calibrated XYZ color sensor provides complete, integrated platform for handheld color analyzers, color calibration and mobile analysis devices. Tri-stimulus XYZ realized by silicon interference filters. UART or I²C slave digital Interface. 16-bit ADC with digital access. Programmable LED drivers. 20-pin LGA package 4.5mm x 4.7mm x 2.5mm, with built-in aperture. Compact true-color sensing. Applications; Color/CCT sensing, Fluid or reagent analysis, Color point comparison, Display calibration.
-
Product
Counters and Timers
-
Orbit Controls counters and timers are designed for connection to practically all industrial sensors and pulse sources . They can be used as process monitors to display the process variable to be measured or as process controllers for control and monitoring tasks. The devices display and process pulses and frequencies, as well as quadrature signals from incremental and absolute encoded rotary encoders. In addition to information on the display, the devices also generate data and analog outputs and monitor preselected limit values. The process parameters are entered via the keyboard so that the display is calibrated in the required units and the output signals, serial interfaces and limit values are optimized.
-
Product
Calibration Tools
ColourSpace PRO Software
-
ColourSpace PRO license tool has been integrated with Plura 4K & 4K-H series for advanced and accurate display profiling and calibration functionalities.
-
Product
Measuring Management
-
Our test equipment is more than a test-set with a screen. Our application software provides an integrated tool to easily store the measurements at different stages and create a log of what we have done. Each measurement stores all data and settings, including display, markers and calibration.
-
Product
Online Dissolved Oxygen Controller
LD-LODC-A10
-
Online Dissolved Oxygen ControllerLD-LODC-A10features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.
-
Product
Online pH Controller
LD-LOPC-A10
-
Online pH ControllerLD-LOPC-A10features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.
-
Product
Handheld Water Quality Meters
LAQUA PC210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Handheld Water Quality Meters
LAQUA PC220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Wavelength and Power Meter
WPM-1NM
-
•Wide range Wavelength Meter– Auto λ detection from 1270nm to 1610nm– Auto power calibration & display•FTTx/PON Wavelength Meter– 1310/1490/1550nm auto λ detection– Auto power calibration & display•Optical Power Measurement– Optical network power measurement– Power measurement for system & module•Insertion Loss Measurement– Optical network & component IL measurement– IL measurement for CWDM 16-wavelength•Smartphone Interface– Communicates with smartphone via bluetooth– Smartphone application software
-
Product
Display Color Analyzer
Model 7123
Analyzer
Luminance and chromaticity measurement of Color Display0.005 cd/m2low luminance measurement (A712301)Wide luminance range: 0.0001 to 25,000 cd/m2 (A712301) 0.01 to 200,000 cd/m2 (A712302)High accuracy measurementMaximum 9 display modes: xyY, TΔuvY, u’ v’ Y, RGB, XYZ, Contrast, ProgramAble to control Video Pattern Generator and UUT (Unit Under Test)Built-in contrast measurement function to calculate the contrast ratio directlyEquipped with programmable test items that can complete the planned tests with one single buttonSupport USB flash disk that can copy the test procedures to other station for useJudgment function embedded to judge the test result automatically with one single buttonCalibration period setting and reminding functionMemory for storing 100 channels of standard color data and calibration dataBuilt-in flat display calibration data LCD-D65 & LED-D65* to be applied for chromaticity measurement instantlyOptional display white balance alignment system can be used to integrate all optical test stations to one single station
-
Product
Online Conductivity Controller
LD-LOCC-A10
-
Online Conductivity ControllerLD-LOCC-A10features 3 points conductivity calibration system, TDS measurement mode, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, Temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. This controller measures Conductivity and TDS values in µS/ cm, and mS/ cm units.
-
Product
Color Test Charts
-
Shenzhen ThreeNH Technology Co., Ltd.
3NH color test charts provide accurate color calibration and image consistency across devices. They are Ideal for cameras, printers, and scanners. These charts meet international standards, helping professionals achieve precise color reproduction in photography, printing, and display calibration workflows.
-
Product
10" In-Vehicle Smart Display With Smart Display Port2.0
TREK-306P FL
Smart Display
Vehicle-grade 10" (4:3) XGA TFT LCD with projected capacitive touchscreen, SDP 2.0 port one cable connect support longer cable length and easy connect/disconnect. Wide working temperature range (-30 ~ 70 °C), Five user-programmable function keys.
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
Calibration Short For Digital Multimeters
34172B
Calibration Short
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
Product
Linear Measurement Kit
55280B
Mechanical Calibration Kit
The Keysight 55280B Linear Measurement Kit is part of the 5530 Laser Calibration System and enables the system to measure linear displacement and velocity along a machine's travel path. The purpose of this measurement is to document capability and, when possible, improve positioning accuracy along an axis for any machine that requires positioning accuracy and velocity control.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
Electronic Calibration Module
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
Mechanical Calibration Kit
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
Mechanical Calibration Kit
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electronic Calibration Module, DC To 9 GHz, 2-Port
N7552A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
Mechanical Calibration Kit
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Mechanical Calibration Kit
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Mechanical Calibration Kit
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
Temp Characterized CalPod, 20 GHz
85531B
Electronic Calibration Module
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards. Very useful in thermal chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the thermal testing to perform a normal re-calibration.
-
Product
Calibration Kit YAV90MMU
YAVMMUCK
Mechanical Calibration Kit
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.