Manual Probe Stations
use hands on manipulation of viewing and positioning controls.
See Also: Probe Stations, Cryogenic Probe Systems
-
product
Environmental Weather Station / Data Logger
Pratt & Whitney Measurement Systems, Inc.
Customizable Display – display any combination of the following outputs
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1P-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1I-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Sealing Kit for PHD-4001A on Cascade Elite E300, Octagon CM300 Probe Station
PHD-4001-TH-Seal
High Power Pulse Instruments GmbH
*Sealing Kit for PHD-PPM10-H9 and PHD-4001A on Cascade Octagon CM300 probe station*High temperature range -40 °C to +200 °C
-
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25Z1-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Power Tube Burn-in Station
Maxi-Burn
The MaxiBurn Tube Preheater is a 2U rack mountable or bench top unit for heating 30 Octal Base Tubes. Designed for continuous use heating standard power pentodes to normalize their characteristics before testing or matching the MaxiBurn powers the tube filaments and drives a nominal plate current through each tube. Normal function of each tube is indicated by a glowing LED associated with the tube.
-
product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25I8-12
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Photomask Stations
Fast, sensitive, economic, off-line photomask defect review. Our 300 series photomask inspection and review stations use long working-distance microscopy and a unique four-way lighting system to greatly speed up location and identification of micron- and submicron-sized defects
-
product
FRP-25T Test System Interface Probe
FRP-25T
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 120Recommended Travel (mm): 3.05Overall Length (mil): 1,210Overall Length (mm): 30.73
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T135
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-C180-3
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70
-
product
High 4.00 (113.00) - 6.70 (190.00) General Purpose Probe
P2550-0-8
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
Your product description goes here.
-
product
Manual Testing Services
With manual testing services, we will hand-pick a team dedicated solely to your project. Our professionals will work with your developers, business analysts, and managers to go over requirements, build a comprehensive test plan, design thorough test cases, rapidly execute the tests, help remediate defects, and retest until the project is satisfactorily completed. The same individuals will be with you from beginning to end, so they have a complete understanding of the project and how you want it done, and you will always know exactly who you are dealing with. The same QA Engineers that develop the test cases will also execute them, leaving no room for misunderstandings and greatly expediting the process.
-
product
Reject Station for X-Ray Image Analyser
IV-110I
IV-11OI is a reject station for X-Ray Image Analyser known for having an X-Ray Image Wire Defect Detection and a compact and space-saving dimension.
-
product
Area Monitoring: Measuring Stations And Measuring Sytems
In everyday life, we are surrounded by electromagnetic fields (EMF) wherever we are. They come from power lines, electricity cables, cellular radio and cordless phones and many other things, too. To protect the general public, the limit values are checked regularly and sometimes monitored continuously. Narda offers various measuring stations and systems for this purpose.
-
product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25I15-12
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
CC15010X, 10 MHz, 150 A Current Oscilloscope Probe
786849-01
The CC15010X, or Hioki 3274, is a clamp-on current probe that offers a wide DC to 10 MHz bandwidth and 150 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
CP-059-19 Battery Probes
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
product
Manual Test Adapters
Manual test adapters (MA) from INGUN are available in several series and series, which differ in terms of use, maximum permitted contact force, parallel stroke, size and service life.
-
product
Probes
Pro-Series®
Pro-Series High Temp Cooking Probe 6" Long probe with a right angle bend for easy pulling from meats or turkeys. Cable withstands 700°F to better withstand broiling and grilling temperatures. Probe tip and sensor read temperatures to 572°F for deep-frying. Good general-purpose probe, the length reaches the center of large roasts and turkeys.
-
product
Ultra High 1.77 (50.00) - 10.00 (183.00) Bead Probe
BTP-25F-10
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2F-1
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Controlled Environment Probe Station
CG-196
Everbeing controlled environment probe station allows vacuum and cryogenic probing down to 77K with liquid nitrogen or high temperature probing up to 1273K. Efficient in characterizing your devices at extreme temperatures, vacuum, specific gas, etc.
-
product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1R2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Alternate 0.99 (28.00) - 6.00 (170.00) Long Travel Bead Probe
BPLT-25HF-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Manual Fixture Kit
230355 – CMK-06
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
product
Test stations
PGT®
Wolfgang Warmbier GmbH & Co. KG
Test station for PGT®120 or PGT®120.COMStand with magnetic document holder made of IDP-STAT®-PVC in size A3Dimensions: 1700 x 590 x 730 mm (H x W x D)Power coated steel frameColour: light grey RAL 7035 / yellow RAL 1003