Luminance
The photometric measure of luminous power.
-
Product
Luminance Colorimeter
-
RayClouds Photoelectric Technology Co.,Ltd.
Measurement parameters: luminance, chrominance, color temperature, flicker, Gamma, etc.Applications: mobile phone screens, small flat panel displays, TV displays, etc.
-
Product
Luminance Colorimeter
BM Series
-
There are various lineups such as hand-held type and measurement of ultra low luminance in short time.
-
Product
Luminance Colorimeter
RD Series
-
RD series can measure not only luminance and chromaticity, but also response and flicker for display and light source.
-
Product
Spectral Radiance / Luminance Calibration Standards
-
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
Product
Image Resolved Luminance Measuring Camera
LMK 6
-
TechnoTeam Bildverarbeitung GmbH
The LMK 6 is TechnoTeam's luminance measurement camera and used in many ways as a standalone measuring device. It is designed to be compact and lightweight and can be used in almost any light measurement application. As it is one of TechnoTeam's core products it is also used in our other camera based measurement systems.
-
Product
Imaging Luminance Meter
CX1000
-
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
CX-1000 imaging brightness meter is used to measure the brightness, brightness distribution and uniformity of LED modules, lamps, lamps, displays, street brightness and other light sources.
-
Product
PHOTO-2000Z Multiphotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
PHOTO-2000Z can be used for luminous flux (supporting integrating sphere) and illuminance test, portable design, high test accuracy, not only suitable for laboratory, quality inspection department, R&D department, but also for industrial and commercial field measurement.
-
Product
18.5" (FHD) Modular Front Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-D18W-FCE
-
350 cd/m² luminance with 1920 x 1080 (FHD) resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
LIMES 2000
-
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
LED Luminous Intensity Distribution Tester
LS860
-
LS860 Luminous Intensity Distribution Tester is a precise electronic instrument for measuring LED luminous intensity. It’s strictly designed according to LED standard requirements of CIE 127-1997 A or B Condition.
-
Product
15" (4:3) Modular Front Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-D15T-CE
-
300 cd/m² luminance with 1024 x 768 resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
15.6" (FHD) Modular Front Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-D15W-FCE
Monitoring Module
450 cd/m² luminance with 1920 x 1080 (FHD) resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
Light Measurement Technology
-
High-precision photometric instruments and systems used to measure quantities like illuminance, luminance, and irradiance.
-
Product
Lux Meters
-
Shenzhen Everbest Machinery Industry Co.,Ltd.
Unit of illuminance and luminous emittance, measuring luminous flux per unit area. It is equal to one lumen per square metre. In photometry, this is used as a measure of the intensity, as perceived by the human eye, of light that hits or passes through a surface.
-
Product
【Slim Bezel】18.5" (16:9) Modular Front Slim Bezel Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-S18W
-
350 cd/m² luminance with 1920 x 1080 (FHD) resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and build-in panel mount kit supportUltra Slim front bezel and status LED indicators
-
Product
Photometric Probes for Illuminance
LPPHOT03… Series
-
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
Product
HAAS-3000/2000 High Accuracy Array Spectroradiometer (Laboratory Grade)
HAAS-3000
-
Hangzhou Everfine Photo-E-Info Co., LTD
HAAS-3000/2000 High Accuracy Array Spectroradiometer delivers various photometric, colorimetric and radiometric parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
Product
PCE Series Opto-Electric Measurement System
-
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
Product
All Digital Luminance-Meter
-
Xinye Optoelectronic Engineering Co.,Ltd.
Designed to measure luminance and chromaticity of light sources.
-
Product
Universal Instrument for Measurement
MI-6201 Multinorm
-
Universal all-in-one instrument for measurement of air temperature, air velocity, relative humidity, illuminance, luminance and the Class 1 (Pro Set) or Class 2 (Euro Set and Standard Set) sounds analyses.
-
Product
Compact Goniophotometer
LSG-1200A
-
The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. • Meets the requirements of IEC, CIE and LM-79 standards • Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements. • Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux • LSG-1200A has included a dark room, measures the maximum size of lamps: 180mm • Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1 • The distance between the tested lamp and detector is 316mm/1000mm • Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5° • The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90° • Test accuracy of angle: ±0.2° Work with the follow instruments as a System
-
Product
12.1" (4:3) Modular Front Display Design Compatible With TPC-B520, TPC-B300 Models
FPM-D12T-CE
-
600 cd/m² luminance with 1024 x 768 resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
Backlight Module Optical Measurement System
-
RayClouds Photoelectric Technology Co.,Ltd.
The DM series backlight module optical characteristic automatic measurement system is equipped with photometer, colorimeter and spectroradiometer to measure the luminance and chrominance, uniformity of the backlight module.
-
Product
Photometers & Colorimeters
-
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
Product
Uniform Light Sources, Luminance Standards
-
Uniform light sources for the adjustment of pixels and intensity of image sensors and cameras as well as for the calibration of luminance and spectral radiance or in other words: Solutions for Imaging, Sensing & Remote Sensor Calibration.
-
Product
Reflex Reflector Measurement Systems
-
Photometric Solutions International Pty Ltd
The measurement setup involves using a projector to illuminate the test item, and then measuring the luminous intensity of the light reflected from the test item. The ratio of the luminous intensity emitted by the reflector (in candelas) to the illuminance on the reflector (in lux) is the coefficient of luminous intensity or CIL (cd/lx).
-
Product
CAS-200 Compact Array Spectrometer
CAS-200
-
Hangzhou Everfine Photo-E-Info Co., LTD
CAS-200 can quickly and accurately measure the spectral power distribution in the range of 380nm ~ 780nm, mainly measuring: the relative spectral power distribution, chromaticity coordinate, color temperature, color rendering index, color tolerance, peak wavelength, FWHM, luminous flux (with integrating sphere) of traditional lamps/light sources, single LED, LED modules and other electric light sources.
-
Product
19" (5:4) Modular Front Display Design Compatible With TPC-B610, TPC-B520, TPC-B300 Models
FPM-D19T-CE
Monitoring Module
350 cd/m² luminance with 1280 x 1024 resolutionHigh durability and performance with industrial-Grade LED LCDAdvanced projected capacitive (P-CAP) technologyIP66-rated front panel and panel mount supportUser-friendly system status LED indicators
-
Product
Display Measurement Systems
DTS Series
-
Instrument Systems Optische Messtechnik GmbH
Characterization of emissive, transmissive, reflective, and transflective displaysViewing-angle-dependent analysis of illuminance, contrast, color, and derived parametersDetermination of the electro-optical transfer function: analysis of luminance, contrast, and color depending on electrical driving conditionsMeasurement of transient properties, such as switching times, flicker, and modulation