Luminance
The photometric measure of luminous power.
-
product
Backlight Module Optical Measurement System
RayClouds Photoelectric Technology Co.,Ltd.
The DM series backlight module optical characteristic automatic measurement system is equipped with photometer, colorimeter and spectroradiometer to measure the luminance and chrominance, uniformity of the backlight module.
-
product
Haze Meter
DRKWGT-2S
Shandong Drick Instruments Co., Ltd.
DRKWGT2S transmittance / haze analyzer is a computerized automatic measuring instrument which is designed based on the People's Republic of China national standard GB241080 "transparent plastic light transmittance and haze test methods" and the American Society for testing and materials standard ASTM D100361 (1997) Standard Test Method for Haze and Luminous Transmittance of Transparent Plastice." It could apply to all transparent, translucent parallel plane sampler (plastic plates, sheets, plastic film,sheet glass) of light transmittance, transmission haze and reflectivity test also applies to liquid samples (water, beverage, pharmaceutical, colored liquid, grease) turbidity measurements in defense research and production workers and peasants to have a wide range of applications.
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
product
BOMBARDING A.C. MILLIAMPERES METER
A Bombarding A.C. Milliamperes Meter is one of the four instruments essential for proper luminous tube processing. This instrument monitors the level of bombarder current in milliamperes that is generated by the bombarder, through the tube being processed. It is necessary to accurately monitor the current for the tubing and electrode sizes used to ensure that the right amount is applied at the appropriate time. To do otherwise may cause damage to the electrodes, fluorescent coating inside the tube and adversely affect the glass structure.
-
product
Portable Luxmeter
HD2102.1
Portable handheld luxmeter for measuring illuminance, luminance, PAR, irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).
-
product
LIMES 2000
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments
-
product
Monochromatic High Power LED Light Sources
LS-HP1 Series
The LS-HP1 is a series of high-power, high brightness light sources for liquid light guides (LLG). It is characterized by its outstanding luminance and thus delivers very high light output from liquid light guides. The LS-HP1 works with the latest generation of high-power LEDs with up to 100W power from an area of less than 15mm². With the LS-HP1 series, we achieve the highest luminance levels through optimized optical coupling into the liquid light guide without heating it up too much. The LS-HP1 is available for liquid light guides with core diameters of 3 or 5mm.
-
product
All Digital Luminance-Meter
Xinye Optoelectronic Engineering Co.,Ltd.
Designed to measure luminance and chromaticity of light sources.
-
product
Laser-Pumped White Light Source
LS-WL1
Our LS-WL1 is a laser-pumped white light source with a light output of up to 440 mW from a 600-µm fiber and a wavelength range of 450 – 700 nm, designed especially for professional requirements for extremely high luminance.
-
product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Light Meters For Photometry
Comprehensive range of solutions for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens) and luminous intensity (cd).
-
product
GO-NR1000 Near-Field Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for LED light source, LED chip, module and other small light source, the principal function includes: spatial light intensity distribution curve, spatial color distribution curve, iso-lux curve, total luminous flux, effective luminous flux, spatial luminance curve, etc.The test data can be saved as IESNA (*.ies), CIBSE (*.cib), EULUMDAT (*.ldt), CIE (*.cie), CEN (*.cen) and other formats, which can be directly used as the input data of international general lighting design software. Spatial luminance data can be imported into near-field lighting generation software to generate light data that can be imported into third parties (TracePro and LightTools).












