Filter Results By:
Products
Applications
Manufacturers
Luminance
The photometric measure of luminous power.
-
product
PCE Series Opto-Electric Measurement System
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
product
2D Video Luminance Meter
LS-ELF
LS-ELF can record 15 frame’s 2D luminance data per second. Also LS-ELF can record the image while driving 60-80km/h speed. It can be used in many fields as Display, Light pollution, Lighting, Lab, etc.
-
product
Light Sources
There are many low cost artificial light sources used for illumination or for industrial applications: tungsten or halogen bulbs, fluorescent lamps, LED lamps etc. Some of these sources have regulated intensity of emitted light. However, there very few calibrated light sources of precisely known parameters. A light source can be considered as calibrated when its user can precisely regulate its photometric/radiometric parameters like luminance (or illuminance), radiance (or irradiance) at defined spectrum of interest. Such light sources are needed in many applications among them, in systems for testing night vision devices, VIS-NIR cameras and SWIR imagers. Inframet offers a series of calibrated light sources that can be divides into three groups:
-
product
Imaging Photometer
L-Series
RayClouds Photoelectric Technology Co.,Ltd.
L-Series Imaging Photometer is equipped with CMOS detector, cooperated with ProICM professional analysis software to detect the luminance parameters of the two-dimensional imaging screen. Professionally complete the data analysis of the measured parameters to help the tester improve the luminance quality of the finished product and ensure the comfortable use experience of end users.
-
product
High Power LED Photo-color-semi Automatic Selector
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
product
Integrating Spheres
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
product
Power Electronics Test Solutions
Chroma Power Electronics Test Solutions not only apply in the industries of Information Technology, Communication, Aerospace and National Defense, but also in energy efficient products such as Hybrid Automobiles, LED luminance devices, solar and fuel cells that are developed aggressively under the pressure of natural resource constraints. Chroma has a wide variety of instrumentation including AC Power Sources, DC Power Supplies, DC Electronic Loads, AC Electronic Loads, Digital Power Meters, and Automatic Test Systems that are ideal for power input/output terminal tests and dynamic simulation.
-
product
Photometric Probes for Illuminance
LPPHOT03… Series
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
product
Photometers & Colorimeters
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Light Meters
TES Electrical Electronic Corp.
Dual Display, 4 digit LCD reading.Spectral Sensitivity close to CIE phototropic curve.Measuring levels ranging 0.001 to 1999kAccurate and instant response. Luminance ratio A/B
-
product
Motor Vehicle Headlight Testers
Foshan Analytical Instrument Co, Ltd.
It can be used to promptly and accurately measure the luminous intensity and the illuminating position(or the optical axis deviation amount) of the high/low beam of vehicle headlight. With the lamp image alignment techique the single-machine high/low beam testing needs only 30-odd seconds.It is also used for the dual-lamp test at the testing station,the dual-machine test at the same time needs only 20-odd seconds.
-
product
Light / Lux Meter, 40000 lx, 0.1 lx, 157 mm, 54 mm, 34 mm
72-9195
Handheld light meter provides a live reading of luminance in most environments. Convenient size easily slips in your pocket or tool kit.
-
product
Haze Meter
DRKWGT-2S
Shandong Drick Instruments Co., Ltd.
DRKWGT2S transmittance / haze analyzer is a computerized automatic measuring instrument which is designed based on the People's Republic of China national standard GB241080 "transparent plastic light transmittance and haze test methods" and the American Society for testing and materials standard ASTM D100361 (1997) Standard Test Method for Haze and Luminous Transmittance of Transparent Plastice." It could apply to all transparent, translucent parallel plane sampler (plastic plates, sheets, plastic film,sheet glass) of light transmittance, transmission haze and reflectivity test also applies to liquid samples (water, beverage, pharmaceutical, colored liquid, grease) turbidity measurements in defense research and production workers and peasants to have a wide range of applications.
-
product
Goniophotometer
GMS2000
In this goniophotometer, the tested luminaire rotates in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The combined motion of the luminaire and mirror permit luminous measurement at the direction of any horizontal or vertical angle without tilting the luminaire, therefore, the luminous intensity will be not variation. The photometer head located at a fixed position of the limiting photomet- ric distance in front of the reflecting mirror to gather the light in each direction.
-
product
High Accuracy Spectrophotocolorimeter
LMS-3000
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
product
Purge & Trap Concentrator
Lumin
In 1974, Tekmar revolutionized the way laboratories performed volatile organic compounds testing. Since then, Tekmar has continued to build on the foundation of the initial Purge and Trap technique for volatile organic compounds, one innovative layer at a time. The Lumin builds on seven previous generations, making Tekmar the industry’s cornerstone of the Purge and Trap process and support.
-
product
GO-NR1000 Near-Field Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for LED light source, LED chip, module and other small light source, the principal function includes: spatial light intensity distribution curve, spatial color distribution curve, iso-lux curve, total luminous flux, effective luminous flux, spatial luminance curve, etc.The test data can be saved as IESNA (*.ies), CIBSE (*.cib), EULUMDAT (*.ldt), CIE (*.cie), CEN (*.cen) and other formats, which can be directly used as the input data of international general lighting design software. Spatial luminance data can be imported into near-field lighting generation software to generate light data that can be imported into third parties (TracePro and LightTools).
-
product
LED Goniophotometer for Lamps
880
Shenzhen Chuangxin Instruments Co., Ltd.
Be used to measure the luminous intensity distribution curve intensity data spread angle and equivalent luminous flux of luminaries. Computer controls the whole test process automatically with low cost and simple operations.
-
product
Spectroradiometer
SR-Series
RayClouds Photoelectric Technology Co.,Ltd.
SR-Series Spectroradiometer is equipped with resolution detectors of different pixel levels, particularly adding a spectroscopic measurement mode, which provides optional specific wavelength intervals for data analysis of the measured luminance, chrominance, color temperature, spectroscopy, etc. Cooperated with ProICM professional analysis software, it can perform high-speed and high-precision measurement of micro luminous surfaces, and provides a new and practical optimization scheme of two-dimensional spectroscopic test.
-
product
Near Field Moving Detector Goniophotometer
LSG-1900B
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
product
Instrumented Runway Visual Range Transmissometer System
AGIVIS 2000
Aeronautical & General Instruments Ltd.
AGIVIS 2000 is a transmissometer-based Runway Visual Range (RVR) system that provides the highest possible levels of accuracy. The first generation of AGI RVR systems were developed in co-operation with the UK Met Office and CAA, and AGI has been supplying RVR systems for more than 25 years. AGIVIS 2000 systems are currently operational at major international airports certified for instrument landings up to and including CAT IIIB. AGIVIS 2000 is fully compliant with ICAO, WMO and CAA requirements. The system consists of transmissometer field sites, background luminance meters, runway lighting interfaces, data processing equipment and archive storage and backup. It can drive multiple full-colour dedicated RVR displays. Systems can be supplied fully installed with comprehensive engineering and operator training, and post-installation support is available worldwide.
-
product
Digital Luminance Meters
All kinds of screen luminance measurement, surface luminance measurement.
-
product
Beam Pattern Measurement System
BP100
The BP100 is purpose-made for luminous intensity measurement of lamps, using a diffusely transmitting screen to provide a flat image that can be measured by an imaging photometer. This is a low cost, versatile solution in comparison to the traditional method of measuring lamp properties as a function of angle of emission, using Goniometers that are often costly and dedicated for one specific measurement.
-
product
Goniophotometer for Traffic Signal Lamps
LSG-1950S
LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors. LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.• Rotations of test samples around both vertical axis (-90°~+90°) and horizontal axis (-35°~+35°) • Accuracy of angle: 0.1° • Resolution of angle: 0.01° • Photometer detector: CIE class A (standard class) accuracy • All software control, high intellectual faculties and simple operation
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
product
GO-2000 Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
GO-2000 is a highly automated luminaire light distribution performance test system, mainly used for all kinds of indoor lamps, road lamps and floodlights ( add B-β test accessories) light distribution performance test, total luminous flux test and electrical parameters (voltage, current, power, power factor) measurement.
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Portable Luxmeter Data Logger
HD2102.2
Portable luxmeter data logger for measuring illuminance, luminance, PAR, irradiance
-
product
LIMES 2000
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments