product
IEC 61850 Testing
HAOMAI Electric Test Equipment Co., Ltd.
IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations. It is a part of the International Electrotechnical Commission's (IEC) Technical Committee 57 reference architecture for electric power systems.
-
product
IEC Potential Transformer Burdens
• Burdens for IEC specifications rated for various input voltages available • 2.5 to 207.5 VA at 0.8 PFIEC Potential Transformer Burdens
-
product
IEC Current Transformer Burden
• Burdens of 1A and 5A for IEC & ANSI specifications are available • 40VA, 20VA, 10VA, 7.5VA, 6.25VA, 5 VA and different combinations of these at 0.8 PF 3.75, 2.5, 1.25 & 1VA at 1.0 PF
-
product
IEC 60068-2-75 IK Spring Impact Hammer
CX-T01
Shenzhen Chuangxin Instruments Co., Ltd.
IEC 60068-2-75 IK Spring Impact Hammer is used for IK Testing. And The IEC 60068-2-75 IK Spring Impact Hammer can be customized the force of 0.14J, 0.2J, 0.35J, 0.5J, 0.7J, 1.0J and 2.0J.
-
product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
product
IEC Standard Burden Sets (Current)
IEC Burden Sets
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
product
Medical Computer Equipped With MXM Graphics Module Supporting NVIDIA Quadro® GPU With 8th/9th Generation Intel® Core™ I7/i5/i3 In LGA1151 Socket. Compliant With IEC 60601-1/IEC 60601-1-2
MLB-3000
- Medical grade computer compliant with IEC 60601-1:2005 + A1:2012 + A2:2020 (3.2 edition) / IEC 60601-1-2:2014 + A1:2020 (4.1 edition)- ADLINK MXM Graphics module support (Type A/B, up to 120W)- 8th/9th Gen Intel® Core™ i7/i5/i3, Celeron® processor- Dual SODIMMs for up to 64GB DDR4 non-ECC memory (dependent on CPU)- DisplayPort (2 from CPU, 4 from MXM)- 1x M.2 E key supporting 1630 or 2230 for Wi-Fi/Bluetooth module, 1x M.2 B key supporting 2242 or 2280 for SATA storage module- Reliable Molex type 12V DC-in connector- 1x Intel® i219-LM and 3x Intel® i210-AT
-
product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
product
An IEC 61000-4-11 Full Compliance Voltage Dip SimulatorModel: VDS-2002
VDS-2002
NoiseKen's new VDS-2002 offers easy and accurate test and following features: Dip, swell, interruption and variation tests up to 16A 240V single-phase AC, interruption test up to 125V DC, preset levels 0%/40%/70%/120%, open and short mode selection for interruption and optional Windows software.
-
product
GOOSEMeter One IEC 61850 Message Monitor
IEC-61850
The GOOSEMeter One is an easy to use, hand held instrument that will instantaneously display the ongoing GOOSE traffic when plugged into an IEC-61850 substation’s control bus LAN
-
product
Noise Dosimeters
Spark Family
Spark® series dosimeters are compact, affordable and tamper-proof personal Noise Dosimeter that measures the following to applicable IEC and ANSI standards:*Noise Exposure: Multiple Dose; Projected Dose; Time Weighted Average; (all with 4 user selectable combinations of Exchange Rate, Threshold, Criterion Level and Criterion Time); Sound Exposure Level*Sound Levels:; Leq; Lmax; Lmin; Lpeak/Luwpk, SEL and more*Time and number of events above Ceiling Level (115 dB) and Peak Level (140dB)
-
product
Partial Discharge Test System
TPP
The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).
-
product
Real-time 1/1, 1/3 Octave Analysis Software
DS-0323
This software analyzes the 1/1 and 1/3 octave bands for 2 - 32 channels (2 - 64 channels when two units are connected ) in real-time from 0.5 to 20 kHz. The filter is compatible with the IEC, JIS, and ANSI standards. The equivalent continuous A-weighted sound pressure level (Laeq) and the single-shot sound exposure level (Lae) are calculated simultaneously by setting measurement time. Variations in level (time series) for each band can be saved for up to 2,000 points.
-
product
IEC60068-2-75 Spring Operated Impact Hammer
CX-T04
Shenzhen Chuangxin Instruments Co., Ltd.
This Spring Impact hammer is strictly designed according to IEC60068-2-75, IEC884 and UL1244 GB/T2423.55-2006, GB4706.1, GB8898 and GB7000 standards. It is used to test the mechanical integrity of product enclosures. After applying the impact with the hammer, the product is examined with accessibility probes to determine access to shock, energy, and injury hazards. Built in exact accordance to IEC\EN, \UL\CSA and other international Standards.
-
product
K Thermocouple Penetration Probe
TP660
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
product
Measurement
Field Uniformity
The purpose of our measurement is to characterise the properties (uniform field area, UFA) of the anechoic room according to IEC 61000-4-3 Ed. 3.1 b or EN 61000 4 3.
-
product
AC/DC Digital Clamp Tester (CE)
M-270
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*True rms reading for ACA and ACV.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.
-
product
IEC60068-2-75 Impact Spring Hammer Single Energy
CX-T02
Shenzhen Chuangxin Instruments Co., Ltd.
Required by many Standards to test the mechanical integrity of product enclosures. After applying the impact with the hammer, the product is examined with accessibility probes to determine access to shock, energy, and injury hazards. Built in exact accordance to IEC, EN, UL, CSA and other international Standards.
-
product
Infusion Pump Tester
IN-600
Measuring and testing device for checking infusion pumps according to IEC 60601-2-24.
-
product
Medical System
Sentinel III
Chroma Systems Solutions, Inc.
The Sentinel III System provides complete Electrical Safety Testing to IEC60601-1 and IEC 60601-2-49 (Multifunctional Patient Monitoring Equipment) in a fully automated fashion. The Sentinel III saves time by scanning patient connections for leakage current without powering down the device.
-
product
Small Full Safety Insulated Crocodile Clip
126017/Colour
IEC 1010 Rating: 300 Volts CAT II Double/Reinforced Insulation 10Amps Standard Colours: Black, Red, Green, Blue, Yellow, White Features: Will accept all standard 4mm plugs.
-
product
Cameras for Mobile Applications
- Programmable to IEC 61131-3 with CODESYS- Robust metal housing for surface or panel mounting- High-performance CAN interface for various communication tasks- E1 type approval (German Federal Motor Transport Authority)
-
product
Digital Power Meter, 30A
Chroma 66205
Chroma Systems Solutions, Inc.
66205 is the 2nd generation of the 66200 series power meter designed specifically for single channel measurement. Its state-of-the-art design is capable of providing highly accurate power measurements to meet the requirements of IEC 62301/EN50564 standards. Functionality improvements of the 66205 increase power measurement capabilities to a wider range of applications.
-
product
Surface Insulation Resistivity Tester
Model SRT1
The model SRT1 is an advanced instrument for measuring surface insulation resistivity following ASTM standard A717 (IEC 404-11). Featuring the improved, patented Allegheny Ludlum Head*, which providesincreased reliability and repeatability while decreasing maintenance costs. Its floating baseplate assures button alignment across the full sample width and length.
-
product
Value-added Module With 4 Terminal Block Isolated CANBus 2.0A/B
VAM101
*4 Terminal Block Isolated CANBus 2.0A/B*Swappable modular design*Maximize I/O flexibility*2kV isolated protection*Designed for tBOX300/500 series*LVD, FCC, EN 50155 and IEC 60945 certified; CE compliant
-
product
Test Equipment For IEC 62133
designed for the battery thermal abuse test for IEC62133-8.2.2. The fire-proof dual-chamber has dimension 10" x 10" x 8", which can be heated up to 180°C via an independent temperature controller with +/- 1°C accuracy.
-
product
Steel Structure Analyzer
NOVOTEST KRC-M2 (Coercive Force Meter)
Steel Structure Analyzer NOVOTEST KRC-M2 is designed for measuring coercive force of metal products in accordance with IEC 60404-7 and is used for non-destructive testing of chemical-thermal, thermal and thermomechanical treatments, evaluation of mechanical properties and residual stresses.
-
product
Power Amplifiers
RF Range
The RF power amplifier range from Laplace is specifically designed for EMC Immunity testing. These are compact units with characteristics matched to the requirements of IEC standards.
-
product
Powerline Analyzer
SHARK 100
Amperis introduces one of the highest performance panel-type billing grade meters in the industry. Based on a new platform, this low cost meter significantly outperforms other much more expensive equipment. This unit is perfect for new measurement applications and for direct and simple replacement of existing analog meters. The Shark is excellent for high accuracy energy measurement exceeding ANSI C12.20 (0.2%) and IEC 687 (0.2%) energy measurement standards.
-
product
Scienlab Dual-Range Regenerative AC / Grid Emulator, 600 / 1200 VAC, 63 / 32.5 A, 45 KW / 66 KVA
SL1214A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.