RF Enclosures
a space surrounded by an electromagnetic radiation barrier
See Also: Faraday Cages, Enclosures, Shielded Box, Shielded Cabinets, Shielded Enclosures, RF Chambers, Shielding Effectiveness
-
product
PXI 16x2 RF Matrix 300MHz 50 Multiway Connector With Loop-Thru
40-728-002-L
40-727/728/729 are RF Matrix Modules suitable for switching frequencies to 300MHz (50Ω version). The modules are available in either 50Ω or 75Ω versions with a choice of coaxial connectors. The 40-727/728/729 are designed designed to provide a simple and scalable bidirectional matrix to RF frequencies. They are intended for the easy construction of high performance bidirectional matrix switching systems.
-
product
RF Test Benches
FIME laboratory equipment qualified for RF testingValidate the analogue behaviour of RF devices with a single set of laboratory tools and services before seeking contactless Level 1 type approval or launching mass production. FIME RF test benches are built for RF testing of: EMV contactless cards and readers; ICAO e-passports and readers; ISO devices (PICC and PCD), HF and UHF RFID tags and readers.
-
product
PXI Quad 4 to 1 RF Multiplexer 3GHz 50 Ohm SMB
40-872-004
The 40-872-004 is a 50 Ohm 4 to 1 RF MUX available with 4 banks in a single PXI slot. It exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-872 has been minimized by careful attention to the mechanical and electrical design.
-
product
9GS/s 16Bit 8GS Mem 4CH 8 Markers RF AWG Benchtop
P9484B
The benchtop version of the Proteus arbitrary waveform generator series offers up to 12 channels in a 4U, 19” benchtop box. With a 9” touch display and on-board PC the benchtop platform enables users to program the instrument without the need of an external PC. Users can program the instrument from the onboard PC using various programming environments such as MATLAB, LabView, Python, and more. So for synchronized, phase coherent, multi-channel applications such as quantum physics and radar applications the Proteus arbitrary waveform transceiver is an ideal, high performance, and cost effective solution
-
product
PXI Dual 2x2 RF Matrix 2.5GHz 50 SMB
40-877-002
The 40-877-002 is a 50Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
product
RF Plasma Generators & Amplifiers
100 W to 2400 W 13.56 MHz Analog/Digital, RS-232, USB interfaces Low Harmonic Distortion Automatic and Manual Gain Control High Speed Pulsing (Bursting) controls Compatible with T&C''''s Matching Networks GUI Software (complete PC control) Includes all essential RF power/communication cables and mounting brackets Air cooled (Air & Water 1200 W +) Half rack mount or stand alone versions Ideal for: Industrial, Scientific, and Medical Applications
-
product
SP2T RF Pin Diode Switches To 18 GHz
Pulsar Microwave's 2-way switches are available in absorptive and reflective designs from 20 MHz to 18 GHz. They are also referred to as single pole, double throw and abbreviated SPDT or SP2T. These switches have a typical VSWR performance of 1.6:1 or better and input power handling of 200 milliwatts maximum. Switching time is 100 nanoseconds, and isolation of 60 dB or greater for most models. Supply voltages are +5V and -5V, with TTL logic control voltage of 0 to 5 volts.Both absorptive and reflective SPDT switches are packaged into Pulsar Microwave's SW2 outline. Configuration is standard with SMA female connectors. Voltage is applied with wire wrap feed thru terminals. The housing serves as electrical ground, and two turret terminals are installed for wiring.
-
product
RF Voltage Probe
P-20 Series
The P-20A is a PASSIVE 10:1 RF VOLTAGE PROBE with a 50 Volt DC BLOCK built in. It has been designed to allow users of RF test equipment to use standard signal tracing techniques. The P-20A makes it possible to conveniently and accurately monitor or inject signals up to 3 GHz into RF circuits without significantly loading or detuning them.
-
product
Modular Solution for RF Switch & Control Tasks
OSP
The R&S®OSP comes in two compact 2 HU models (R&S®OSP220, R&S®OSP230) and one large 3 HU model (R&S®OSP320) to meet diverse test scenario requirements – ranging from desktop configurations for laboratory measurements to complex, rack-integrated test systems. The R&S®OSP230 model comes with a manual control touchscreen. The R&S®OSP320 model has a monitor option.
-
product
RF and Microwave USB Programmable Signal Generators
LSG Series
The Lab Brick LSG series of low cost USB-compatible RF and microwave signal generators covers frequencies from 20 MHz to 6 GHz with high output levels and excellent spectral purity. They require no additional DC supply voltage and offer several operating modes, including continuous-wave (CW) and swept-frequency. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.
-
product
PXI Dual 6 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated
40-881-002
The 40-881 is a 50 Ohm 6 to 1 6GHz multiplexer available as a single or dual MUX in one and two PXI slots respectively. The 40-881 exhibits low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the 40-881 ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
product
PXI-2593, 500 MHz, 50 Ω PXI RF Multiplexer Switch Module
778793-01
500 MHz, 50 Ω PXI RF Multiplexer Switch Module—The PXI‑2593 can be programmatically configured as unterminated multiplexers, externally terminated multiplexers, or dimensionally flexible sparse matrices.
-
product
PXI-2545, 2.7 GHz, 50 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module
778572-45
2.7 GHz, 50 Ω, Terminated 4x1 PXI RF Multiplexer Switch Module—The PXI‑2545 is an RF signal multiplexer switch module. The internal termination of the PXI‑2545, which helps prevent high-power reflections that arise from open channels on the module, makes it ideal for use in RF applications where such reflections can damage the source. The module also provides excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
RF Shielded Test Enclosure, I/O Intensive Device Tests
JRE 1720
Like its other brothers in the JRE test line, it features rugged welded aluminum construction with superb RF shielding effectiveness. Long life door gasket material along with double edge engagement not only provides solid RF shielding, but smooth trouble-free operation over its lifespan. A JRE exclusive, our triple door locking mechanism allows easy single handle door operation. Ventilation is standard with our JRE exclusive honeycomb style vents in enclosure rear and door.
-
product
RF / MW switch
The RF / MW switch includes a variety of RF and microwave switch modules - RF multiplexers, which are available for use in the 34980A multifunction switch / measurement unit, providing broadband switching from DC to 20GHz . Use these modules to route test signals between your device under test and a signal source, oscilloscope, spectrum analyzer, or other instrument. The switch / attenuator driver module also controls the external switches and attenuators of the 34980A.
-
product
RF Synthesiser
The Laplace Synthesisers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 230MHz for conducted tests and 30MHz - 6GHz for radiated tests. They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
-
product
6U VPX Direct RF Processing System
VP460
The VP460 is designed to enable customers to begin development of their next generation systems using revolutionary new processor technology. It is in alignment with the SOSA™ Technical Standard to provide the interoperability required by the US Air Force, Army and Navy.
-
product
PXI Single RF Attenuator 63dB in 1dB steps
41-180-021
The 41-180 Programmable Attenuator Module is available with either one or two independently programmable attenuators in a single width 3U PXI module
-
product
RF Test Spectrum Measurements over CPRI
Integris 3000
Most modern cell tower network configurations place the Remote Radio Head (RRH) at the top of the tower and the baseband unit(BBU) at the bottom of the tower. While this configuration is advantageous for both computational efficiency and mitigation of RF loss across the cable, it means the only place along RF can be accessed is at the top of the tower. This forces field technicians to have to climb the tower to measure and debug RF noise problems.
-
product
RF Power Amplifiers
Specially selected products to complement our ultrasound measurement equipment.
-
product
L-Band RF Tuner and 2-Channel 200 MHz A/D with Virtex-6 FPGA - 3U VPX
Model 52690
- Accepts RF Signals from 925 to 2175 MHz- Programmable LNA boosts LNB (low noise block) antenna signal levels with up to 60 dB gain- Programmable analog downconverter provides I + Q baseband signals with bandwidths ranging from 4 to 40 MHz- Two 200 MHz 16-bit A/Ds- Supports Xilinx Virtex-6 LXT and SXT FPGA- 2 GB DDR3 SDRAM or 32 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- Clock/sync bus for multiboard synchronization- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
product
Wattchman RF Station Monitor/Alarm Systems
81080 Series
The Coaxial Dynamics Wattchman Monitor/Alarm measures forward and reflected RF power simultaneously in 50-Ohm coaxial cables and transmission lines. It is compatible with our entire series of 7/8" through 6-1/8" Line Sections and will accept plug-in elements that range from 5 watts to 100 kW full scale from 0.45 MHz to 2300 MHz.
-
product
RF Routing Switches
Quintech Electronics and Communications Inc.
RF Monitoring and Routing Switch.
-
product
PXI Quad 4 to 1 RF Miltiplexer 6GHz 50 Ohm SMA Terminated
40-882-004
A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
product
PXI/PXIe RF Matrix, Dual 2x2, 2.5GHz, 50Ω, SMB
40-877A-002
The 40-877A-002 (PXI) and 42-877A-002 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
product
PXI/PXIe RF Switch, Hex SPDT, 3GHz, 75Ω, SMB
40-830A-006
The 40-830A-006 (PXI) and 42-830A-006 (PXIe) are 75Ω RF switches with 6 separate SPDT relays in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
Faraday Chamber for RF w/Exchangeable Cassettes 340x350mm RCV 9025 for 6TL36
AN133
The Faraday Chamber is an add-on for the 6TL36 test handler. This kit is installed into the 6TL36 in the same way a normal test fixture would be installed, being the only difference the fact that different products to be tested will, from that moment on, only need an additional exchangeable cassettes to be tested.
-
product
PXI 8x9 RF Matrix 500MHz 50 SMB
40-725-511
The 40-725 is an 8x9 RF Matrix Module suitable for switching frequencies up to 500MHz (50Ω version). The 40-725 is available in either 50Ω or 75Ω versions with SMB coaxial connectors. It is intended for the easy construction of high performance bidirectional matrix switching systems. Automatic Isolation Switches are located on all coaxial connections, these disconnect the matrix from the external test fixture maximizing isolation and RF performance.
-
product
RF Power Splitter, Combiner, Divider
PD2430
INSTOCK Wireless Components, Inc
Wideband Frequency (350 - 1000 MHz)Low Insertion Loss (0.3 dB avg)High Port to Port Isolation (28 dB avg)Excellent VSWR (1.15 : 1 avg)RoHS Compliant Splitter ConstructionTri Alloy SMA Female (Jack) Low PIM
-
product
PXI-2557, 2.5 GHz, 75 Ω, 8x1 PXI RF Multiplexer Switch Module
778572-57
2.5 GHz, 75 Ω, 8x1 PXI RF Multiplexer Switch Module—The PXI‑2557 is an RF signal multiplexer switch module. The higher channel count of the PXI‑2557 makes it ideal for test systems that require the switching of a large number of video RF signals, such as switching several video tuners under test to a single channel on the RF analyzer. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.





























