Positioning
Aligning test set with target geography.
-
Product
Differential Pressure Adapter w/ App Compatibility
DPA1
-
UEi Test & Measurement Instruments
The DPA1 measures positive, negative and differential pressure and is compatible with iOS® and Android™ mobile devices. Measurement units can be selected from the following scales: InH2O, mmH2O, psi, bar, mBar, kPa, InHg and mmHg. The mobile device screen will display a numeric reading. And is backed by a 1-year warranty.
-
Product
Two -Dimensional PSD
-
Functions according to the Lateral Effect Photodiode principle. It is an analogue device and therefore displays excellent position resolution. The resolution is determined by the system signal-to-noise ratio. It is operated in the biased mode. Typical applications include: distance andheight measurement, alignment, position and motion measurements and vibration studies
-
Product
EMC Actuator for Accelerator Pedal
PSE-G
-
Pneumatically operated actuator for operation of accelerator handle. External set-point of the pedal actuator position via analog voltage to closed-loop pressure regulator in external valve box.
-
Product
4 Channels, 2-28 Vrms Input, 5 kHz-10 kHz
LD3
-
A linear variable differential transformer (LVDT) is a type of electrical transformer/transducer used for measuring linear displacement (position). A counterpart to this device used for measuring rotary displacement is called a rotary variable differential transformer (RVDT). The RVDT is like an LVDT in that it measures a positional displacement, however, the displacement, which is still a linear proportional function, is based on rotary instead of linear positional movement.
-
Product
POWER PROBE 4
PP401
-
*Electronic circuit and component tester that supplies battery ground and power along with 8 diagnostic testing modes to provide automotive technicians with detailed information on the circuits and signals being tested*Diagnostic Modes include: AC/DC Voltmeter, Ohmmeter, Frequency, Pulse width (Positive and Negative) Fuel Injector Tester, PCM/ECM Driver Tester and PPECT3000 Signal tracer*Tests for AC/DC voltage in 100ms and 50s resolutions, AC volts RMS and volts peak-to-peak, measure resistance, frequency and pulse width (negative and positive)
-
Product
Ohmmeters
-
GAOTek provides state of the art, professional grade Ohmmeters for sale to the United States, Canada and Globally. GAOTek Ohmmeters are portable instruments that accurately measure electrical resistance between two points on a circuit. The Ohmmeters have their own power supply through their own battery, and are needed when the two probes (red: positive side of circuit, black: negative side of circuit) are connected to the two points in the circuit where the desired measurement is to take place. The circuit is turned off, which is when the ohmmeter sends its own current through the circuit. Units of Ohms, symbolized by the Greek letter Ω (Omega), are used as a unit of measure when measuring electrical resistance. In accordance with Ohm’s law, when the current is passing through a circuit is at its maximum, the resistance is said to be the smallest.
-
Product
Fluorescence Microscopes
-
Bruker’s suite of fluorescence microscopy systems provides a full range of solutions for life science researchers. Our multiphoton imaging systems provide the imaging depth, speed and resolution required for intravital imaging applications in neuroscience, oncology and immunology. Our confocal systems enable cell biologists to study function and structure using live-cell imaging in cell cultures and invertebrate model organisms at speeds and durations previously not possible. Bruker’s super-resolution microscopes are setting new standards with quantitative single molecule localization which allows for the direct investigation of the molecular positions and distribution of proteins within the cellular environment. Our latest addition, Luxendo light-sheet microscopes, are revolutionizing long-term studies in developmental biology and investigation of dynamic processes in cell culture and small animal models.
-
Product
Cable Locator
CL 20
-
Cable fault location with the BAUR CL 20. The CL 20 cable locator comprising a transmitter and a receiver is used to determine the exact location of cables and metal pipes. The ability to determine laying depths of up to 4.5 m and to measure signal currents at the touch of a button allows you to obtain reliable information on the position of the cable within the shortest time.* Fast and exact location of position and laying depth of cables* Intuitive operation – no special measurement knowledge required* Lightweight and manageable
-
Product
Impact Testing
-
When you need to evaluate how your product & materials react to shock loading, Trialon is here to help. By utilizing our laser-aiming test stand to create consistent positioning and ball impact, you can trust that Trialon has the equipment and personnel to conduct your test accurately and timely.
-
Product
Hand Held Needle Detector
UI-G60
-
Hand held needle detector, using the principle of magnetic field, can accurately detect the specific location of ferromagnetic metal impurities such as broken needles, which is very suitable for the inspection of thin and small items. It is also suitable for the detection of large needle detectors. It can accurately find the position of steel needles or ferromagnetic metals in a small range with this hand-held needle detector, avoiding the damage of metal impurities to consumers and manufacturers, and improving the quality of enterprise products.
-
Product
Digital Engine Analyzer/Multimeter
385A
-
The #385A has many of the necessary features required for today’s automotive diagnostics. Use frequency readings to test crankshaft and camshaft sensors, for example. The #385A comes equipped with an RPM pick-up, probe test leads, alligator clip test leads, protective holster, instructions and installed 9V battery. Inductive RPM pick-up features a five position, adjustable sensitivity switch.
-
Product
On-line FT-NIR Analysis
MATRIX-F
-
The advantages of real time, on-line FT-NIR analysis have been well established. However, conventional spectrometers can only be installed close to the process that they are monitoring, which makes the analyzer be exposed to a hostile environment, like drastic temperature changes and exposure to dust and dirt. Furthermore, the instrument needs to be positioned in hard-to-access and often Ex-protected area.
-
Product
Finger Saver
21250
-
Ingenious device prevents stabbing your finger! Quickly, easily and safely guides the pick point of most circuit testers into the center of all primary automotive electrical wire. Holds the circuit tester in position allowing technician to work with both hands free. Impervious to gasoline, oil, thinners and other shop chemicals. Stores on ground wire of circuit tester.
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
E37 THT Vertical | Non-Threaded | Up To 4.5 Ncm
E37-VNxx2/3/5/6/8/9/E/F/G
-
Incremental encoder with dual function and without thread, 16 detent positions, switching torque up to 4.5 Ncm and a rotational life up to 1 Mio revolutions
-
Product
Bus Digital-Synchro-Resolver
PC104
ITA
Computer Conversions Corporation
The PC104-DS Series are Low Cost, Dual Channel, PC104 Compliant Digital / Synchro / Resolver Output Cards designed to simulate precision AC Synchro and resolver formatted signals for use in navigation and positioning systems or test sets on both industrial and COTS - military type applications.
-
Product
Industrial encoders incremental
-
Precise position and speed feedback even in demanding environments.
-
Product
Tool Positioner Balancer
-
The Mini 31 balancer is a small, lightweight tool positioner that allows tools to be positioned over a work area for comfortable operation. The tool will remain at whatever level or position that it is left at. The operator can set the desired tension rate by simply placing a screwdriver into the slotted shaft and turning clockwise to increase tension and counterclockwise to decrease tension.
-
Product
Signal/Thermocouple, Module, Receiver, TriPaddle/ Thermocouple, 84/12 Position
510104261
Receiver Module
Signal/Thermocouple, Module, Receiver, TriPaddle/ Thermocouple, 84/12 Position
-
Product
NI-9361, 32-Bit, 8-Channel C Series Counter Input Module
783407-01
Counter Input Module
32-Bit, 8-Channel C Series Counter Input Module - The NI‑9361 is a differential or single-ended input module. With this module, you can expand beyond the four counters in CompactDAQ to reach up to 64 counters per 8‑slot chassis. You can configure each channel to read a single pulse train or combine them to read up to four incremental encoders. You can also directly connect sensors with open-collector or push-pull outputs by using an internal switchable 1 kΩ pull‑up resistor. The NI‑9361 counters can perform encoder position and velocity measurements. You can synchronize the counters with other analog, digital, and counter measurements in your chassis.
-
Product
Blank, Module, ITA, Pull-Thru, 1 Position
510130284
Blank Module
Blank, Module, ITA, Pull-Thru, 1 Position.
-
Product
PXI Module Adapter, Pull Thru Adapter, Receiver, 1 Position
510109462
Adapter Module
PXI Module Adapter, Pull Thru Adapter, Receiver, 1 Position.
-
Product
Mini Coax, Module, Receiver, 90 Series, 19 Position
510104120
Receiver Module
Primary mating module 510108111. (May mate with other ITA modules, as well.)
-
Product
6U CPCI Multifunction I/O Board
78C1
Multifunction I/O
The 78C1 is a universal 6U cPCI Multifunction I/O Board that eliminates the complexity and size constraints of using multiple, independent, single-function cards. This single slot card has six module positions, allowing developers to achieve a custom configuration with any combination of function modules, such as A/D (10-channels), D/A (10-channels), Discrete I/O (16-channels), TTL I/O (16-channels), Differential Multi-Mode Transceivers (11-channels), RTD (6-channels), Synchro/Resolver (4-channels), LVDT/RVDT (4-channels), and Signal Generator (4-channels).
-
Product
High-Performance Beamsplitters
-
Optical beamsplitters play a vital role in many laser-based measurement and positioning systems. Although the operation of a typical beamsplitter is conceptually simple, its performance characteristics can dramatically affect the accuracy and repeatability of the overall system. Consequently, understanding the variables that distinguish beamsplitter performance is an important step in comparing and specifying components. There are two basic types of beamsplitters:
-
Product
Detector And FPA Testing
-
The FPA Test Set (FPATS) interface to the detectors under test (DUT’s) is via a custom pedestal plate which provides both a conductive heat path to both the individual DUT’s as well as the field of view limiting aperture plate. This custom pedestal plate protrudes through the customer provided DUT interface printed circuit board (PCB) and makes physical contact with the rear of the DUT packages and the aperture plate when the FPATS is in the closed position. The pedestal plate is mounted to the ambient source plate and its temperature is actively driven by this subsystem.
-
Product
Power Source Unit
SM7860
-
Power Source Unit Ideal for MLCC Leakage Current Measurement. The SM7860 series allows for setting the dual-line output voltage on 8 channels or 16 channels, and enables up to 32-channel of output. The Hioki SM7860-5x/SM7860-6x series is a 32-channel, 500V / 1000V power source for the Hioki SM7810 Super Megohm Meter, providing positive and negative polarities required for MLCC test lines.
-
Product
Embedded Rod Style LDT
-
AMETEK Sensors, Test & Calibration
The 958A Embedded Linear Position Transducer is a Rod Style LDT (Linear Displacement Transducer) that is designed fit entirely inside of hydraulic cylinder. The 958A provides absolute analog feedback in the most demanding applications.
-
Product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
785190-01
Voltage Output Module
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.
-
Product
Signal, Module, Receiver, QuadraPaddle, 90 Series, 192 Position, Fully Loaded w/ Twin Female Contacts & Square Posts for Wire Wrap (p/n's 610138200 & 610138118)
510150136
Receiver Module
Primary mating module 510151105. (May mate with other ITA modules, as well.)





























