AC DC Electronic Loads
-
Product
AC & DC Electronic Loads
-
The Adaptive Power Systems Electronic Loads cover a wide range of power levels, voltage and current profiles and feature sets.Supported voltages range up to 1250Vdc or 350Vrms AC. From bench to system and DC or AC requirements, we can more than likely offer you the optimal programmable load to meet your needs.
-
Product
AC / DC Electronic Loads – Benchtop Testing to Automated Test Systems
-
Chroma Systems Solutions, Inc.
Chroma is the global leader in Electronic Load manufacturing. Chroma’s AC Electronic Loads are designed for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources, and other power devices such as switches, circuit breakers, fuses and connectors. Chroma’s DC Electronic Loads are used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, and fuel cell testing. Chroma loads can do it all including full current down to 0.4VDC, CZ mode, user defined waveforms, timing measurements, and 3 current ranges per load. Chroma’s electronic loads come standard with either USB or RS232 ports for control and can be configured for GPIB (IEEE-488) control as well.
-
Product
Modular Power
-
AMETEK Programmable Power, Inc.
ReFlex Power™ is a high density, programmable power module system providing DC, AC and electronic load assets all under control of a single controller. ReFlex Power™ (RFP™) provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test.
-
Product
RFP DC Low Power
-
AMETEK Programmable Power, Inc.
ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.
-
Product
AC & DC Electronic Load
3270 Series (350V,1875W~22500W)
-
3270 Series is suitable for the step, square and sine wave of the AC Power device test, especially for the uninterruptible power supply UPS, Inverter, fuses, circuit breakers, power regulator AVR, battery, AC / DC power supply / components ... and so on, absolutely is the best test solution in the market.
-
Product
Modular Power
RFP Controller
-
AMETEK Programmable Power, Inc.
ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.
-
Product
Modular Power
RFP Chassis
-
AMETEK Programmable Power, Inc.
ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.
-
Product
Electronic Loads
-
We offer devices that provide wide-ranging AC, DC, and AC/DC electronic load capabilities to meet a variety of telecommunications, manufacturing, utility, and other applications. Our models accurately simulate the operational load that equipment.
-
Product
AC Electronic Load
-
AC&DC Electronic Loads are design for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources and other power devices such as switches, circuit breakers, fuses and connectors.
-
Product
Modular Power
RFP DC High Power
-
AMETEK Programmable Power, Inc.
ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.
-
Product
Regenerative AC Emulator, 1200 VAC, 65 A, 90 KVA, 3‑Phase
SL1213A
AC Emulator
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
DC Electronic Load, Single-Input: 150V, 40A, 250W
EL33133A
Load Module
The Keysight EL33133A bench DC electronic load provides a single input and a built-in data logger. Provide static or dynamic load test up to 40 A and 150 V. Display results in a meter view or over time using the built-in data logger.
-
Product
DC Electronic Load Module, 1U Height, 60 V, 40 A, 200W
N6792A
Load Module
The Keysight N6792A is a 200W, 1U electronic load module for the N6700 series modular mainframe.
-
Product
600 Watt Electronic Load Module
N3306A
Load Module
The Keysight N3306A is a 600 W (0-120A, 0-60V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3306A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3306A can also digitize waveforms.
-
Product
Regenerative AC Emulator, 600 VAC, 125 A, 90 KVA, 3‑Phase
SL1203A
AC Emulator
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
600W Bench Electronic Load, Dual Input 150V, 60A, 300W
EL34243A
Load Module
Keysight’s EL30000 Series bench electronic loads consist of three models, all with a built-in data logger. The EL33133A basic performance electronic load offers an economical price, a limited range, and a single 40 A, 150 V, and 250 W input. Two performance models offer additional ranges, the EL34143A single input 60 A, 150 V, 350 W, and EL34243A dual input 60A, 150V, 600 W.
-
Product
Regenerative AC Emulator, 600 VAC, 63 A, 30 KVA, 3‑Phase
SL1201A
AC Emulator
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
PXIe-4051 - PXIe, 1-Channel, 60 V, 40 A PXI Electronic Load Module
788179-01
Load Module
The PXIe-4051 provides programmable load capable of sinking DC power for characterization, design validation, and manufacturing test. This module helps you sink current and absorb power out of a power source up to 300 W with programmable constant voltage, current, resistance, and power levels. You can use the PXIe-4051 to streamline the task of designing automated test systems for a wide range of applications—from aerospace and defense to automotive and semiconductor component test—by eliminating the need to mix multiple instrumentation form factors in a given test system and simplifying synchronization.
-
Product
Modular Power
RFP DC Load
-
AMETEK Programmable Power, Inc.
ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
Electronic Calibration Module
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Scienlab Dual-Range Regenerative AC / Grid Emulator, 600 / 1200 VAC, 63 / 32.5 A, 45 KW / 66 KVA
SL1214A
AC Emulator
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
Scienlab Dual-Range Regenerative AC / Grid Emulator, 600 / 1200 VAC, 63 / 32.5 A, 90 KW / 135 KVA
SL1215A
AC Emulator
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
250 Watt Electronic Load Module
N3303A
Load Module
The Keysight N3303A is a 250 W (0-10A, 0-240V) electronic load module for use in either the N3300A or N3301A electronic load mainframe in system applications. The N3303A load module is fast and accurate, for programming in constant current, constant voltage, or constant resistance modes, or for making voltage, current or power measurements. The N3303A can also digitize waveforms.
-
Product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
Electronic Calibration Module
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
Product
Integrated AI-ADAS ECU And Cameras For Large Commercial Vehicle
ADM-TJ30
Electronic Control Unit
The integrated AI-ADAS ECU is connected to 8 cameras and powered by the vision-AI algorithm. It can detect and classify different kinds of vehicles/ pedestrians/ two-wheeler riders/ lane marking and other objects to perform multiple ADAS functions.
-
Product
Regenerative AC Emulator, 1200 VAC, 32 A, 45 KVA, 3‑Phase
SL1212A
AC Emulator
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
Load Module for SLSC
Load Module
Bloomy's 8-Channel Load Module provides isolated current and voltage measurements for eight on-board 5W loads or for eight off-board 120W loads. With built-in switching for calibration and fault injection, the module provides unsurpassed capability for Mil/Aero applications. The module also provides switching and connections to allow switching between a real load (e.g., actuator, valve, etc.) and the simulated load.
-
Product
Temp Characterized CalPod, 20 GHz
85531B
Electronic Calibration Module
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards. Very useful in thermal chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the thermal testing to perform a normal re-calibration.