Product
3-Dimensional Loop Antenna Van Veen
-
Loop Antenna System ( LAS )3-dimensional large loop antennadiam. 2 macc. EN 55015 / CISPR 15
-
Product
Synchro or Resolver Angle Indicator Readout
AITM
-
Computer Conversions Corporation
This series of units were designed to satisfy Hi speed multiturn synchro/resolver applications where the output data must be fresh and no data staleness can be tolerated. The tranducers utilized are the same as in the regular MDS series, however different tracking electronics are used.
-
Product
Magnetic Pole Indicator
-
identification of the field-direction of a magnet (north - south). It simply ascertains, fast and reliably the polarity of permanent magnets and electromagnets. This reliable device is simply to be served. It is indispensable for all industrial areas and fields of investigation which deal with magnetic applications.
-
Product
U Type Glow Wire Loop
IEC60695-2-10
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thermo resistance, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a standardized test platelet made of plastic (or other materials) for a prescribed period of time under precise test conditions.
-
Product
Inspection Instrument for Indicators
i-Checker
-
The i-Checker is specially designed to calibrate measuring accuracy of dial indicators, dial test indicators, and other electronic comparison gage heads with a stroke of up to 100mm (4").±(0.2+L/100)µm indication accuracy. Directly inspects an indicator with a stroke of up to 100mm (4"). The dial test indicator, bore gage and lever-type inductive head can be inspected with optional accessories. Adjustment of the measurement position is very easily accomplished because of semi-automatic measurement and full automatic measurement functions. Creates and prints out the simple inspection certificate. Saves inspection result as CSV file for reusable inspection result by any kind of software.
-
Product
Process Indicator
CS1-PR
-
CS1-PR economic type Process Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~10V and 4(0)~20mA.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.
-
Product
Continuity Tester with Audible Indication
TEK402
-
The Martindale TEK402 is a low cost, easy to use continuity tester with audible indication. The loud buzzer makes it easy to use in noisy environments.
-
Product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
-
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
Product
Digital Indicators
-
The precise measuring of dimensions is important for so many enterprises: engineering, surveying, construction, machine tooling and auto manufacturing, just to name a few. And electronic digital indicators provide people in these fields with the means to accurately measure the dimensions of objects both very small and very large by translating small linear distances into rotational movement. Precision measuring tools like electronic digital indicators can also be used to measure distance and range. If your job requires mechanical testing or machining, you may want to shop our selection of dial indicators.
-
Product
Modular Breakout System for Hardware-In-Loop Simulation
-
Designed in partnership with OPAL-RT Technologies, this Modular Breakout System combines a BoB feature set with the added flexibility of an FIU. By mating the FIU chassis directly to the BoB using our plug-in modules, cabling is minimized, creating a more compact reliable design and improving signal integrity.
-
Product
Load Cell Indicators
-
Procter & Chester Measurements Ltd
The instrumentation will power the load cell. The mV/V signal coming back from the load cell is converted by the indicator and displays the force in a unit (e.g.: Kg, kN, lb – customers choice). The indicators within this range are encased so that the operator can either use it on the move (if battery powered) or be a permanent fixture, e.g.: wall mounted.
-
Product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
-
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
Product
Single Loop Controller
1160+
-
The 1160+ controller is an evolved product from the West N6100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
Product
Active Loop Antenna
AL-130R
-
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
Product
Milliamp Calibrators & Loop Calibrators
-
Practical Instrument Electronics, Inc.
PIE has milliamp calibrators to fit your needs from the PIE 334 with the basic functions of a 4-20 milliamp calibrator to the advanced loop troubleshooting capabilities of the Model 532. And PIE milliamp calibrators are the only models with patented Loop Diagnostic Technology! All the loop calibrators have fuse-less protection, rugged design, long battery life. Calibrate in the units matching your instruments by displaying in milliamps and percent (%) of 4 to 20 milliamps.
-
Product
Save A Watt® Phantom Power Indicator
P4190
-
The Save A Watt® Phantom Power Indicator offers an easy way to save money by showing you how much power your electronics are using in standby mode. Whether it’s a cell phone charger using 5 watts, or a video game using up to 15 watts, this simple device will show you how much they’re using.
-
Product
Line Loop Tester
8455
-
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
Product
Rain Indicator Data Logger
HD2013-DB
-
Rain indicator Data Logger with LCD display; reads and stores up to 32,255 pulses coming from a rain gauge with tipping bucket.
-
Product
Synchro and Resolver Angle Indicator
AIT5
-
Computer Conversions Corporation
This series of units were designed to satisfy Hi speed synchro/resolver applications where the output data must be fresh and no data staleness can be tolerated. The tranducers utilized are the same as in the regular MDS series, however different tracking electronics are used. The resultant data tracks the input shaft perfectly and is always fresh and accurate at input speeds up to 64 revolutions per second, depending on the resolution. Data in BCD or Binary formats are available, and clean, unambiguous crossovers are guaranteed.
-
Product
Loop Meter
MZC-310S
-
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
Product
Indicators and Displays
-
CR Magnetics Indicators are designed to give the designer an easy low cost method of sensing electrical properties. Useful for quick and easy analysis of heater elements, lighting filaments, and motor operation, these products save money by increasing efficiency, decreasing down time, and improving maintenance operation.
-
Product
Phase Sequence Indicator
-
Cambridge Instruments & Engineering Co.
Phase sequence indicator is a must for checking new electrical connections, installation and maintenance. It is useful in wiring of switchboards, when 3 phase watt meters and power factor meters are connected. In wiring 3 phase AC motors rotation can be checked and corrected if need be, by checking the sequence.
-
Product
Fuse Buddy Current Loop
307M/308B
-
*Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
Quad Op-Amp Loop
QOAL400
-
The QOAL400 module is a precision instrument capable of measuring all common parameters of an Op Amp, including AC as well as DC parameters. The QOAL400 has four completely independent channels, which allow a quad device to be tested in a minimum amount of time. Each channel has a full set of resources to measure all common parameters.
-
Product
4 Digit Angle Position Indicator (API)
TA-900
-
This has been the New standard in Angle Position Indicators. 4 digit API has fault monitoring for both low-level and loss of signal (LOS) and this status is shown on the front panel led. The unit provides simultaneous connection of both synchro and resolver devices.
-
Product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
-
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
Product
Digital Indicating Pressure Transmitter
DSGT
-
Series DSGT Digital Indicating Transmitter is a versatile multi-function process gage that features an excellent 0.25% full scale accuracy.
-
Product
Short Circuit Loop Impedance Meter
AMZC-306
-
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more