Standard Transformers
-
product
Transformer Polarity Checker
865
This instrument is used to check the correctness of polarity markings on transformers. In operation, the two leads carrying the test current are connected to one of the transformer windings. The other two leads from the indicating meter are connected to the other winding.
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
Light Sources & Calibration Standards
Photometric Solutions International Pty Ltd
We offer a range of specialised and customised light sources for various applications.The spectral range goes from 200 nm to 40 µm.
-
product
Hydrogen Frequency & Time Standard
CH1-1007
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2LB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Series Standard HV Capacitors
PMT10000
Power Measurement Technologies Inc.
High voltage, low dissipation factor, gas-filled Standard Capacitors for indoor use in a laboratory or production environment. A three terminal design configuration allows accurate measurements of capacitance and dissipation factor (tangent delta) with little or no effect from test lead or stray capacitance.
-
product
Calibrated Diffuse Reflectance Standards
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
product
Standard Helmholtz Coils
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
product
Single Gas Transformer DGA
Hydran composite gas Dissolved Gas Analysis (DGA) products provide essential online monitoring of transformer oil. The Hydran line is the perfect cost-effective application for small- and medium-sized transformers where customers need to know about developing fault conditions that could cause unscheduled outages.The Hydran products allow for the addition of expansion to the base unit, allowing for greater measurement accuracy
-
product
Standard Type
FD-10
This device supports the measurement of rivers, Agricultural water, Sewage systems, Other channels and facilities.
-
product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2LB-8
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Impedance Standards and Calibrators
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
product
Nanolattice Standards for Analytical Instruments
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of Electron and Atomic Force Microscopes (AFM). Make the grade, with the highest quality pitch standard of its kind available.
-
product
Viscosity Standards
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
product
Instrument Transformer Calibrators
MRL 22
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
product
Power Transformer
We are amongst the leading names in the industry, offering wide range of Power Transformer that are technically advanced in nature and have high strength. Our entire product line is dimensionally accurate in nature and requires low maintenance cost. They are thermostatically balanced in nature AND are easy to install.
-
product
OIP TYPE VOLTAGE TRANSFORMER
12kV - 145kV post type voltage transformers having Oil Impregnated Paper( OIP) as major insulation has been designed with several unique features.OIP insulated outdoor products are subjected to extreme climatic conditions and hence extra care is taken in the design and manufacturing of such transformers.
-
product
Split Core Current Transformer
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
product
Standard Directional Gyroscopes
4000B-series
The 4000B is our standard air-driven directional gyro. As the aircraft turns left or right, gears on the sensing unit and dial shaft translate this rotation into rotation of the instrument’s vertical dial. Left turns produce clockwise dial rotation and right turns produce counter-clockwise rotation. The gyro is controlled by a heading selector knob located on the lower left of the instrument. Pressing and turning the knob first disengages the dial shaft and then resets the dial to a new heading, which results in a new course indication. Releasing the selector knob re-engages the dial shaft. The on-course position of the pointer is always at the top of the azimuth circle (0° on the dial with the aircraft headed north).
-
product
Phase Shifting Transformer
Supreme Instrument Laboratories
Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.
-
product
The Standard R&D Wafer-Lifetime Tool
WCT-120
Best available lifetime measurement accuracy. Measure lifetime and surface recombination for a wafer of any quality or crystallinity.
-
product
Standards and Regulations
Is your organization ready to engage in the world of autonomous and electric vehicles?
-
product
FTIR – Fourier Transform Infrared
FTIR stands for Fourier Transform Infrared spectroscopy. It is a powerful gas measurement technology for simultaneous measurements of multiple gases. The ability to detect and measure almost any gas, combined with the robustness and reliability of the technology, makes FTIR ideal for a wide variety of applications.
-
product
Insulating Transformer Oil Test Set
NMC make Insulating BDV Oil Test Set are used to check the di-electric strength of the transformer oil.
-
product
Automatic Voltage Regulating Relay- Standard Model
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
Transformer Capacity Load No-load Tester
HTRS-V / 261
Wuhan Huatian Electric Power Automation Co., Ltd.
High precision instrument used in transformer capacity, no-load, load and other characteristic parameters measurement.
-
product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-F200-1
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
product
Standard Resistor Oil Bath
9400
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
product
Transformer Oil Breakdown Voltage Tester
HBVT
Hention Electrical Equipment Co., Ltd.
HBVT Transformer Oil Breakdown Voltage Tester , in accordance with IEC156, is designed to check insulating oil’s dielectric strength.The test set is compact and portable, therefore suitable for field work.





























