Voltage Preamplifiers
-
Product
sbRIO-9225, Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module
780588-01
-
Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The sbRIO‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three sbRIO‑9225 channels. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9223, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781398-01
-
±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.
-
Product
NI-9222 , ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783283-01
-
±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
Product
Preamplifiers
LNA Series
-
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
783732-01
-
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
NI-9260, 51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module
783466-01
-
51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module - The NI‑9260 is an instrument-grade dynamic signal generator for testing the audio components and capabilities of consumer electronic devices and providing excitation in structural test applications. Unlike sound card-based solutions, the NI‑9260 can be deployed quickly and recalibrated to guarantee long-term measurement repeatability and decreased test time. It also features ±30 V overvoltage protection and short circuit protection.
-
Product
NI-9224, ±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783862-01
-
±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9224 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9224 is simultaneous sampling with two options for filtering a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
Transformer Preamplifier
SR554
-
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
Product
Microphone Preamplifier
426A05
-
Preamplifier for 1/4" side vented prepolarized microphones.
-
Product
Current Preamplifier
1641
-
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
780180-01
-
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
Acoustic Emission Preamplifier
-
The Acoustic Emission Preamplifier is a instrument designed specifically for use with acoustic emission sensors, which is used to boost the signals and filter out any noise or interference. With its advanced technical features and robust design, the QingCheng Acoustic Emission Preamplifier is the perfect choice for professionals seeking a high-performance acoustic testing solution.
-
Product
NI-9223, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783284-01
-
±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.
-
Product
sbRIO-9201, Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
781114-01
-
Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The sbRIO‑9201 is an effective combination of channel count and speed at a low price for an economical multifunction system. In addition to the absolute protection from the isolation, the module features up to 100 V of overvoltage protection for errant signal connection or unexpected outputs to the individual channels. Non-enclosed modules are designed for OEM applications.
-
Product
sbRIO-9201, Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
781113-01
-
Non-Enclosed, ±10 V, 500 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The sbRIO‑9201 is an effective combination of channel count and speed at a low price for an economical multifunction system. In addition to the absolute protection from the isolation, the module features up to 100 V of overvoltage protection for errant signal connection or unexpected outputs to the individual channels. Non-enclosed modules are designed for OEM applications.
-
Product
Microphone Preamplifier
426B31
-
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
Product
10-Ch. 0… 5V 400mA Isolated
YAVAP955
-
The YAV board AP955 contents 10 CAN Bus programmable bipolar Isolated precision and low noise 0 to 5VDC voltage sources up to 400mA output, with Tripaddle VPC connector.
-
Product
NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783107-01
-
250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.
-
Product
NI-9260, 51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module
783467-01
-
51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module - The NI‑9260 is an instrument-grade dynamic signal generator for testing the audio components and capabilities of consumer electronic devices and providing excitation in structural test applications. Unlike sound card-based solutions, the NI‑9260 can be deployed quickly and recalibrated to guarantee long-term measurement repeatability and decreased test time. It also features ±30 V overvoltage protection and short circuit protection.
-
Product
sbRIO-9239, Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780875-01
-
Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9209 , ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
785042-01
-
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
Product
NI-9202, ±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module
784399-01
-
±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module - The NI-9202 has excellent flexibility to meet the needs of your applications. The module has 16 simultaneous sampling, differential input channels to create large, distributed systems in a rugged form factor. It also has configurable filters to eliminate noise in your system while maintaining low-latency to be used in control systems.
-
Product
Preamplifiers
-
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
Product
Pre-Amplifiers
MPR, MDA series
-
MPR, MDR series provides low noise, high gain and wideband to improve dynamic range for emission testing. We also offer customized model for variable requirments.. Example 30M-1000MHz with band-pass filter Amprifier unit for connecting antenna directly
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
Product
Preamplifiers
AH-series
-
A broad mix of in-line preamplifiers and accessories are offered to enhance hydrophone measurements by increasing the gain, preserving the flatness response, extending the dynamic range, and minimizing reflections.
-
Product
Isolated AC Voltage Input Module
ADAM-3112
-
0 ~ 450 VAC to 0 ~ 5 VDCAC voltage measurement1,000 VDC isolation between output and power2,500 VAC isolation between output and inputInput impendent: 2 MohmMulti input modesAccuracy: ±0.1% FSRFlexible Din-rail mountingOperates from a single +24VDC
-
Product
Microphone Preamplifier
426A30
-
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
Product
RX Pre-Amplifier System
RAM-34
-
The RAM-34 is a complete pre-amplifier system designed primarily for the low bands 160M thru 40M. It has inputs for four receive antennas and internal 3-pole bandpass filters for 160M, 80M and 40M. In addition to the pre-amplifier, it has a step attenuator that togetherwith the amplifier stage provides gains from -20 dB to +20 dB in 5 dB steps. This allows equalizing the signal levels between the antenna inputs. Gain settings are memorized for each antenna on each band. Different types of receive antennas have different signal levels and the gain memories eliminate the need to adjust the receiver or pre-amplifier when switching between the antennas.
-
Product
Modern Prepolarized Precision Condenser Microphones & Preamplifiers
-
Modern prepolarized microphones are designed with newer technology than traditional externally polarized microphones. Prepolarized microphones have many advantages over the externally polarized models. They use ICP® power circuitry invented for sensors by PCB®. By applying a polymer coating to the top of the backplate and embedding a charge on it, expensive 200V power supplies can be eliminated and 2-20 mA constant current supplies or signal conditioners can be used as the power source.





























