-
Product
Electronic Load System
-
Electronic loads are required for testing fuel cells such as PEMFC, AFC, PAFC, MCFC, SOFC. These electronic loads are designed either in IGBT technology with power, current and voltage ranges according to specific requirements or in transistor technology. Electronic loads in IGBT technology are designed for high voltage ranges up to 900 V, current ranges up to 1000 A, and power ranges up to 480 kW.
-
Product
Battery Load Testers
-
Electronic devices designed to test the remaining capacity of a battery's overall charge.
-
Product
Data-logger
11275
-
Comes loaded with M. C. Miller’s Pipeline Survey software application for “Over-the-Pipe” Surveys:• Close Interval Potential Surveys (CIPS or CIS)• DCVG Surveys• Combined (single-pass) DCVG/CIS Surveys• Surface Potential Surveys
-
Product
Ultrasonic Bolt Meter - Bolting System
Mini-MAX-Series
-
The MINI-MAX, Ultrasonic Bolt Tension Monitor, defines the state of the art in the measurement of the actual elongation produced by tightening a threaded fastener. The MINI-MAX can measure the elongation very accurately in fasteners of virtually any material from 1/2 inch to 4 feet in length. The measurement is achieved by determining the change in the transit time, of an ultrasonic shock wave along the length of the fastener as the fastener is tightened by any method. The on-board microcomputer automatically interprets this time measurement to display the time(nanoseconds), elongation, load, stress, or %strain from stretching a fastener. Through the use of high speed digital signal processing and automated diagnostics, the MINI-MAX minimizes the requirement for extensive operator training. With built in data recordation and reporting through an RS232 interface, the MNI-MAX offers an easy to use and reliable solution to the most difficult bolting problem.
-
Product
Portable Electricity Meter Testers
EE-120A-1S
-
The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.
-
Product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (f)
CK058F
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Electro-Dynamic Vibration Test System (Air Cooled)
-
HIACC Engineering & Services Pvt. Ltd.
The air-cooled electro-dynamic vibration test system has a wide frequency range, high reliability, easy to operate and small foot-print area. The force ranges from 1kN to 70kN, and maximum load is from 70 kg to 1000 kg. This product can be integrated with HIACC’s environmental chambers.
-
Product
Automatic Calibration Module
ACM2509
-
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Load Optimization
-
Designed to monitor, control, and reduce expensive electricity consumption peaks in industrial, commercial, and administrative environments.
-
Product
DC Electronic Load
EE30180A
-
The EE30180A DC Electronic Load / Works @ 0.0 Volts Input & real time I/O control. attach the electronic load block to a heat- sink and your up and running.
-
Product
Electronic Loads/Sinks
-
An electronic load offers the possibility of testing the specimen under different loads. Various load changes are simulated, as they can occur in normal operation. For this purpose, the relevant load current is set in a defined range and electronically controlled. For the test, different operating states are either programmed or entered into the system via an interface (USB, RS-232, GPIB...). For easy handling and quick use, there are four operating modes.
-
Product
I-V Measurement Systems
-
The I-V Curve Data Acquisition includes a fixture for holding cells for testing (see Figure 1 below). This fixture can accommodate cells from small to up to 100 mm x 100 mm. Adjustable cell stops, in the X & Y-axis, are provided to consistently locate the cells for testing. Two micro-manipulators are provided as shown in Figure 1. Each micro-manipulator has two spring loaded contacts to allow 4-wire measurement even for cells that have top contacts only. Two back-side voltage contacts are embedded in the Plate (galvanically isolated from the Plate) and make good electrical contact when the cell is held down by vacuum to the plate. All voltage and current probes are gold-plated. The cell is held down with vacuum during testing (built-in vacuum pump).
-
Product
Universal Testing Systems (Up To 300 KN)
6800 Series
-
Instron’s 6800 Series universal testing systems deliver high-performance mechanical testing up to 300 kN. Designed for precision and durability, these systems offer exceptional measurement accuracy (±0.5% down to 1/1000th of load cell capacity) and fast data acquisition rates up to 5 kHz. Ideal for tensile, compression, flexure, torsion, peel, lap shear, and many other test types, the 6800 Series provides the flexibility and control needed to handle everything from delicate specimens to high-strength materials, making it a trusted solution for demanding testing environments.
-
Product
Safety Products
-
This ACE product group provides Emergency braking to safely slow down moving loads and reduce damaging forces. Although the safety shock absorbers, TUBUS elastomer bumpers and clamping elements differ so much in design, every single ACE component provides the best protection for your machine.
-
Product
(25kN) Fatigue Testing Systems
8872
-
The 8872 fatigue testing system is ideal for fatigue and static testing of biomedical, advanced materials, and manufactured components. The servohydraulic actuator is conveniently located in the crosshead for easy table mounting. The T-slot base makes it easy to secure orthopaedic specimens, automotive components, and manufacturing assemblies. The adjustable crosshead, actuator-mounted load cell, and corrosion resistant T-slot base with unique drain channel are essential for testing biomedical specimens immersed in a saline bath.
-
Product
PXI 5A Mux 8-Bank 5-Ch Isolated COM
40-651-014
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
Instrumentation
-
Complementing our range of force and torque sensors, we offer a comprehensive range of graphical displays, including the Digiforce, which are PLC controllers and data loggers all in one. Together with a fully comprehensive range of standard high speed load cell displays with analogue output.
-
Product
Bidirectional Programmable DC Power Supply
IT6000C Series
-
The bi-directional programmable DC power supply of IT6000C series combines two devices in one: a power supply (source) and an electronic load (sink) with energy recovery. Based on these two functions, IT6000C offers the functionality of two-quadrant operation. The regenerative capability enables the energy consumed to be put back onto the grid cleanly, saving costs from energy consumption and cooling, while not interfering with the grid.
-
Product
Animal Temperature Controller- Dual Feature
TCAT-2DF
-
This is a combination version which includes both and AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low noise DC output for heating pads. This version allows you to controls a variety of different loads.
-
Product
Arbitrary Load Control For Modulation Distortion - Export Control
S94571B
-
Load pull capability for modulation distortion measurements up to 50 GHz for export controlled countries
-
Product
Motive Power Load Banks
-
The only way to be certain that your stationary batteries will perform to specification is to test the batteries’ capacity with a DC load bank / portable battery discharge tester.
-
Product
Bench Power Supply, Adjustable, 2 Output, 0 V, 32 V, 0 A, 3 A
72-8690A
-
The 72-8690A from Tenma is a dual channel general DC power supply suitable for laboratory use. The dual channel (CH1 and CH2) can work in CV or CC mode and these two modes convert automatically according to the load. The CH1 and CH2 have auto tracking function. In this condition, the output of CH2 tracks the output of CH1. This function is usually used when adjustable symmetrical and double polarity power is required. Both CH1 and CH2 display the output voltage or current with a 6 digit LED meter. The main outputs can be connected in parallel or in series. This product comes with 2 years warranty.
-
Product
Digital Indicator for Strain Gauge Sensors
AD-4530
-
Low cost digital indicator for various applications. Suitable for measurement of load, pressure, torque, tension and more at an affordable price.Digital Zero (DZ) stores zero data at any measurement point. This function can also be used to tare weight. Measurement can simply be restarted when it was interrupted by a loss of power.Power on zero function adjusts to zero when the power is turned on.Digital filter provides stable measurement results.Digital span calibration. Easy calibration just by inputting the rated output of a sensor. No need to use a mass.
-
Product
Sensor Cable
-
Connects bridge-based load cells, pressure transducers, and torque sensors to NI devices. Additionally, the SH96F-96M-5 is available in different lengths.
-
Product
4A Solid State Flasher, AC Input
A915-8
Solid State Flasher
NAI’s A915-8 is a 4 A, AC Input, Aircraft Warning or Navigation Light Flasher. With low RFI/EMI, zero crossover switching employed in the output circuits, this solid state, single channel unit provides long device and load life.
-
Product
2 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 2 Ports
GPS212
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
NI TB-2643B Terminal Block for NI 2532B as 1-Wire Dual 4x64 Matrix or 2-Wire 4×64 Matrix Topology Without Column Protection Resistors
782385-07
Terminal Block
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
48V / 300 Amp Load
BD18-48P
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 48V and 50V, (24 or 25 cells at 2V each), battery systems and is extremely cost effective.
-
Product
Clamp Meter
ST-3347W
-
Standard Instruments Co., LTD.
This clamp meter provides accurate AC, AC/DC current and voltage readings regardless of the waveforms. This meter can use in most industrial and commercial applications where non-linear loads distort the current or voltage waveform. Reliable operation. Features accessories such as test leads, carrying case and temperature probe.
-
Product
3 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 3 Ports
GPS312
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm





























