NI TB-2642B Terminal Block for NI 2532B as 1-Wire 16x32 Matrix Topology Without Column Protection Resistors
782385-05
Terminal Block
The TB-2642B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 1-wire 8x64 matrix. You can directly connect the TB-2642B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2642B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 Matrix topology With Column Protection Resistors
782385-14
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Precision Source/Measure Unit, 1 Ch, 10 FA Resolution, 210 V, 1.5 A
B2910BL
Source Measure Unit
The Keysight B2910BL Precision Source / Measure Unit (SMU) is a 1-channel, compact and cost-effective bench-top SMU with the capability to source and measure both voltage and current. It is versatile to perform I/V (current vs. voltage) measurement easily with high accuracy. Integration of 4 quadrant source and measurement capabilities enables I/V measurement simply and easily without configuring multiple instruments.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
NI TB-2643B Terminal Block for NI 2532B as 1-Wire Dual 4x64 Matrix or 2-Wire 4×64 Matrix topology With Column Protection Resistors
782385-08
Terminal Block
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
Motion Control Terminal Board For Mitsubishi J2S-A Servo Amplifiers
DIN-812M0
Terminal Board
- On-board connector type: 100-pin SCSI-II female- Suitable for Mitsubishi J2 super servo- Dimensions: 123 mm x 107 mm x 44 mm (WxLxH)- Available for PCI-8132
-
Product
Precision Source / Measure Unit, 1 CH, 1 PA Resolution, 21 V, 1.5 A
B2901BL
Source Measure Unit
The Keysight B2901BL precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
Coaxial Short
85140B
Terminator
The Keysight 85140B coaxial short is used for establishing measurement planes for known reflection phase and magnitude in 50-ohm coaxial systems. It has a 2.4 mm female connector.
-
Product
PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit
782856-02
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PCIe to PXI Remote Control Interface Kit
41-924-001-KIT
Remote Control
The kit is supplied with a PCIe card which can plug into any PC PCIe slot, a PXI module for insertion into Slot 1 of a PXI chassis and 3m lead to connect the two parts together. The interface uses a single lane PCIe connection from the PC to provide a software transparent link from the PC PCIe backplane to the PXI backplane. The supplied 3m shielded lead ensures the system has robust operation and an adequate separation distance between the PC and the PXI chassis.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXIe Source/Measure Unit, 15 MSa/s, 1 PA, 60 V, 3.5 A DC/10.5 A Pulse
M9602A
Source Measure Unit
The Keysight M9602A is a PXIe SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
Optical/Electrical Clock Recovery
N1077B
Clock and Data Recovery Unit
N1077B Optical/Electrical Clock Recovery provides standards-compliant clock recovery capabilities for multimode and single-mode optical as well as electrical signals from 125 MBd up to 64 GBd PAM4 and NRZ
-
Product
PXI Remote Control Interface Cable, 7m
41-924-700
Remote Interface Cable
The 41-924-700 is a 7m cable accessory for the PCIe to PXI Remote Control Interface Kit. The kit provides a seamless connection between a PC’s PCIe slot and a PXI chassis and is suitable for providing an interface to any PXI chassis.
-
Product
15-Pin Female D-SUB to 15-Pin Female Screw Terminal, DIN Rail Terminal Block
785334-01
Terminal Block
15-Pin Female D-SUB to 15-Pin Female Screw Terminal, DIN Rail Terminal Block - The 15-Pin D-SUB to Screw Terminal provides a DIN rail terminal block for CompactDAQ and CompactRIO controllers.
-
Product
96-Pin DIN Male to 96-Pin DIN Female, PXIe-4330 and PXIe-4331 to Rack-Mount Terminal Block, Shielded Sensor Cable
786341-01
Terminal Block
Shielded Cable for PXIe-4330 and PXIe-4331 to Rackmount Terminal Block, 1 Meter
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
42-205-008 (PXIe) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix topology With Column Protection Resistors
782385-04
Terminal Block
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Precision Source / Measure Unit, 1-Channel, 10 FA Resolution, 210 V, 3 A DC / 10.5 A Pulse
B2911B
Source Measure Unit
The Keysight B2911B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXI-4132, 100 V, 2 W Precision PXI Source Measure Unit
780558-01
Source Measure Unit
±100 V, 10 pA Precision PXI Source Measure Unit—The PXI-4132 is a programmable, high-precision source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4-wire) sense as well as external guarding. With its high measurement resolution integrated guarding, the PXI-4132 is ideal for high-accuracy leakage measurements on integrated circuits, discrete components, PCBs, and cables. You can also perform high-speed I-V measurements on a variety of components including diodes and organic LEDs using the onboard hardware sequencing engine. In addition, you can synchronize multiple PXI-4132 modules using the PXI backplane to provide high-speed I-V measurements on transistors and more complex devices.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
TB-2651, Screw Terminal, 8x32, Dual 1-Wire PXI Module Matrix Terminal Block
781131-04
Terminal Block
Screw Terminal, 8x32, Dual 1-Wire PXI Module Matrix Terminal Block - The TB-2651 provides the necessary routing to configure the PXI-2531 or PXIe-2531 PXI Matrix Switch Module as a 1-wire dual 8x32 matrix. You can directly connect the TB-2651 to the front panel I/O connectors of the PXI-2531 or PXIe-2531.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Source Measurement Unit
PEMU4
Source Measure Unit
The PEMU4 represents a new level of performance and capabilities for USB-based SMU (Source MeasurementUnit) instrumentation. The PEMU4 supports -1V to +6.5V 0.5A with FVMI, FVMV, FIMV, FIMI modes. 4 channel can be ganged to support high current driving. I2C/SPI/RFFE function for serial port device testing. 4 Counter for frequency measurement.
-
Product
Input Terminal Block For Digital Multimeters
34171B
Terminal Block
The Keysight 34171B DMM input terminal connector block is a set of two connectors which provide a convenient and reliable method to connect wires to all five input terminals. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals. For minimum thermal offset voltages, use unplated copper wire of the same gauge for all connections.
-
Product
PXI Based Multifunction Measurement and ICT Instrument
PXI-501
Multifunction Switch/Measure Unit
The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.