Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Coaxial Short
85140B
Terminator
The Keysight 85140B coaxial short is used for establishing measurement planes for known reflection phase and magnitude in 50-ohm coaxial systems. It has a 2.4 mm female connector.
-
Product
Precision Source / Measure Unit (2 Ch, 100 FA)
B2902B
Source Measure Unit
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXIe-4142, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit
782430-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit - The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
Fault Insertion Unit
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
Precision Source / Measure Unit (2 Ch, 10 FA)
B2912B
Source Measure Unit
The Keysight B2912B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
Terminal Block For 34937A And L4437A GP Switch
34937T
Terminal Block
Provides a flexible method for connecting discrete external wiring; detachable with screw-type connections.
-
Product
PXI/PXIe Source Measure Unit Family
PXS(e)840x
Source Measure Unit
The PXS840x PXI SMU family is a high-speed, 4-quadrant source measure unit. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
Precision Source / Measure Unit, 1-Channel, 10 FA Resolution, 210 V, 3 A DC / 10.5 A Pulse
B2911B
Source Measure Unit
The Keysight B2911B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
NI TB-2627 Screw Terminal Block for NI PXI-2527
779358-01
Terminal Block
The TB-2627 provides the necessary routing to configure the PXI-2527 or PXIe-2527 PXI Multiplexer Switch Modules as a single or dual 1-, 2, or 4-wire multiplexer. You can directly connect the TB-2627 to the front panel I/O connectors of the PXI-2527 or PXIe-2527.
-
Product
PXIe-4144, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit
782432-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit - The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
Product
PXI Based Multifunction Measurement and ICT Instrument
PXI-501
Multifunction Switch/Measure Unit
The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.
-
Product
PXI Remote Control Interface Cable, 7m
41-924-700
Remote Interface Cable
The 41-924-700 is a 7m cable accessory for the PCIe to PXI Remote Control Interface Kit. The kit provides a seamless connection between a PC’s PCIe slot and a PXI chassis and is suitable for providing an interface to any PXI chassis.
-
Product
TB-2648, Screw Terminal, 4x128, 1-Wire PXI Module Matrix Terminal Block
781131-01
Terminal Block
Screw Terminal, 4x128, 1-Wire PXI Module Matrix Terminal Block - The TB-2648 provides the necessary routing to configure the PXI-2531 or PXIe-2531 PXI Matrix Switch Module as a 1-wire 4x128 matrix. You can directly connect the TB-2648 to the front panel I/O connectors of the PXI-2531 or PXIe-2531.
-
Product
PXI Remote Control Interface Cable, 3m
41-924-300
Remote Interface Cable
The 41-924-300 is a 3m cable accessory for the PCIe to PXI Remote Control Interface Kit. The kit provides a seamless connection between a PC’s PCIe slot and a PXI chassis and is suitable for providing an interface to any PXI chassis.
-
Product
Coaxial Open, 2.4 mm (m)
85141A
Terminator
The Keysight 85141A coaxial open is used for establishing measurement planes for known reflection phase and magnitude in 50-ohm coaxial systems. It has a 2.4 mm male connector.
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
Source Measure Unit
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
3U cPCI Sensor Interface Unit
SIU31
Sensor Interface Unit
NAI's SIU31 is a highly configurable rugged COTS system or subsystem ideally suited for military, industrial, and commercial applications that require high-density I/O, communications, Ethernet switching, and processing. The SIU31 uses one NAI field-proven, 3U cPCI board to deliver off-the-shelf, SWaP-optimized COTS solutions that "Accelerate Your-Time-to-Mission."
-
Product
Terminal Block For 34951A And L4451A D / A Converter
34951T
Terminal Block
Provides a flexible method for connecting discrete external wiring; detachable with screw-type connections.
-
Product
96-Pin DIN Male to 96-Pin DIN Female, PXIe-4330 and PXIe-4331 to Rack-Mount Terminal Block, Shielded Sensor Cable
786341-05
Terminal Block
Shielded Cable for PXIe-4330 and PXIe-4331 to Rackmount Terminal Block, 5 Meter
-
Product
CB-68LPR, I/O Connector Block
777145-02
Terminal Block
68-Pin Female VHDCI Right Angle to 68-Pin Female Screw Terminal, Desktop Mount Terminal Block - The CB-68LPR is a terminal block with 68 screw terminals for easy connection of field I/O signals to 68-pin NI data acquisition devices. It includes one 68-pin male connector for direct connection to 68-pin cables. This CB-68LPR features standoff feet for use on a desktop or mounted in a custom panel. The CB-68LPR also has a right-angle-mounted, 68-pin connector.
-
Product
21-Ch 6A-250VA 2-Bus Fault Insertion
YAV90077
Fault Insertion Unit
21 channels 1 thread 6A 250V 2 Fault Insertion Buses Switching up to 250W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Coaxial Termination, DC to 26.5 GHz
909D
Terminator
The Keysight 909D is a precision, low-reflection dc to 26.5 GHz load for terminating a 50-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
Coaxial Open, 2.4 mm (f)
85141B
Terminator
The Keysight 85141B coaxial open is used for establishing measurement planes for known reflection phase and magnitude in 50-ohm coaxial systems. It has a 2.4 mm female connector.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Motor Termination Units
-
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.