Impedance
-
Product
Antenna Impedance Converter
-
The low noise impedance matching equipment has a high impedance input with minimized capacity. With the 50 Ω output it can be used with common EMI receivers or spectrum analyzers to measure the emissions received by an antenna on a vehicle.
-
Product
Battery Impedance Tester
-
Weshine Electric Manufacturing Co., Ltd
The DC test method is adopted to simulate the actual use of the battery in a real and objective way, which can effectively eliminate the hidden dangers such as deficiency, deficiency and connection failure between batteries while measuring the internal resistance of the battery.
-
Product
Electrical Impedance Tomography
-
Electrical Impedance Tomography (EIT) is an imaging technique that visualizes conductivity or impedance distributions both in 2D and in 3D. Sciospec is partnering with world leading scientists in the field to deliver solutions that enable using EIT both in research and in practical applications.
-
Product
FC Impedance Meters
-
designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.
-
Product
Impedance Analyzer 1MHz-20Hz
IA1000
-
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
Product
Line Impedance
KIT
-
The Line impedance kit is composed of two modules, STLG and STSG. The kit is meant to be used with STS 5000, STS 4000 and eKAM in order to perform Line Impedance test.
-
Product
Impedance Analyzers
-
Sciospec stands for Electrical Impedance at its Best. Electrical Impedance Spectroscopy has been our core technology ever since. In the past years we have developed a scalable and flexible technology plaform that allows for precise, customizable, yet cost-effective lab-bench impedance analyzers. Choose between our three standard instruments, add some powerful options and enjoy an impedance analyzer that perfectly fits for your application.
-
Product
Vector Impedance Analyser
TE3000
-
The TE3000 Vector Impedance Analyser is a portable desktop instrument designed for high accuracy impedance measurement. The probe style construction and small output signal make it ideal for "in circuit" impedance characterisation of small signal devices without the risk of damage to the device under test. The TE3000 comes factory calibrated to the tip of the probe with optional custom calibration. Turn it on, set the frequency, take a measurement, and display the results in any format.
-
Product
Step & Touch & Earth Impedance
-
The kit applyed with STS 5000, STS 4000 or eKAM, allows to perform the following types of test: soil resistivity, ground grid resistance, step and touch tests and overhead lines zero sequence and mutual coupling coefficients
-
Product
High Impedance Active Probes
12C
-
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
Product
Battery Impedance Tester
KVBT-15S
-
KV Hipot Power Test Equipment Co.,Ltd
Battery Internal Resistance Tester with advanced AC discharge measurement method, is applied to test accurately the voltage and resistance of battery capacity and state.
-
Product
High Impedance Active Probes
34A
-
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.
-
Product
Impedance Stabilization Network
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH8158 is a device for measuring the common mode interference voltage of unshielded twisted pair cables. Cable testing according to CISPR 16-1-2. The equipment under test (EuT) and auxiliary equipment (AE) are directly connected to the corresponding ports. The port adopts RJ-45 socket (the distribution conforms to T568A/B.) This equipment is divided into three specifications: CAT3, CAT5, and CAT6, and the corresponding equipment is selected according to the cable model.
-
Product
High Impedance Probes
-
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
Product
Automated Tuners / Impedance Tuners / Load Pull Tuners
-
MT97x, MT98x and XT98x series automated tuners (also known as automated impedance tuners and automated load pull tuners) are precision instruments that are optimized for a broad class of in-fixture and on-wafer applications, and may be used in any automated or manual application requiring the ability to match the impedance of a microwave circuit element or to establish specific impedances at a terminal interface. The tuner design is based on the slide screw concept using the inherently broadband slab-line transmission structure. Each unit has two non-contacting probes deliver high VSWR with superb accuracy and reliability over a wide frequency range. These probes can be fully retracted leaving a low-loss, well-matched transmission line, which is a significant benefit in power related applications where two-port tuners capable of handling large amounts of power are required. As integral components of Maury Device Characterization Solutions, these PC-based tuners are controlled using Maury's family of Device Characterization Software tools, including MT930 IVCAD, MT993 ATS and the DLL-based measurement automation environment. Maury Microwave automed impedance tuners are ideal for load pull, harmonic load pull, active load pull, hybrid active load pull, noise figure, noise parameters and all automated tuner applications.
-
Product
Controlled Impedance Analyzers
-
HYPERLABS Controlled Impedance Analyzers can be used with various probes and adapters to quickly and reliably characterize impedance on PCB test coupons. These Test Systems are designed to comply with IPC-2141A standards for PCB coupon testing, and can be customized to meet specific customer needs.
-
Product
High Impedance Transformers
-
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
Product
Overhead Line & Cable Impedance Test Sets
-
T&R Test Equipment Overhead Line & Cable Impedance Test Sets
-
Product
Controlled Impedance Field Solver
Si8000m
-
TheSi8000m is an all new boundary element method field solver , which builds on the familiar easy to use user interface in earlier Polar impedance design systems. The Si8000m adds enhanced modeling to predict the finished impedance of multiple dielectric PCB builds and also takes into account the local variations in dielectric constant on close spaced differential structures.
-
Product
Short Circuit Loop Impedance Meter
AMZC-304
-
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
Product
Impedance Matching Pads
-
Surface mount and coaxial 50 Ohm / 75 Ohm impedance matching pads for CATV systems, broadband networks, test setups and more!
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
Arbitrary Load-Impedance X-Parameters
S94520B
-
S94520B Arbitrary Load Impedance X-parameters enables an X-parameter model to be collected over a user defined set of load impedances. S94520B still requires an application to control the load impedance such as S94521B or Maury ATS or IV Cad.
-
Product
Impedance Analyzers
-
A/D converted input signals undergo discrete Fourier transform (DFT) to calculate complex impedance values and obtain parameters and characteristics specific to the DUT, such as its capacitance, inductance and quality factor. Original NF algorithms are also applied to allow equivalent circuits made up of R, L and C along with the constants for those circuits to be estimated from the complex impedance spectrum obtained by sweeping the frequencies.
-
Product
Impedance Analyser Frequency Response Analyser
C60
-
The C60 investigates the opaque world of analog networks. The unit operates in two test modes. It can measure the frequency response of a two port system producing a gain/loss and phase graph. It can also measure the reactive response of a two terminal network producing an impedance/admittance and phase graph. Electronic, electrical, electro-acoustic and other networks can be tested with sine wave excitation and the results displayed on a PC.
-
Product
Impedance Measurement
CITS880s
-
Finer geometries and thinner copper can present a challenge for fabricators measuring impedance on leading edge PCBs. The CITS880s answers that challenge with the introduction of Launch Point Extrapolation (LPE). LPE extrapolates the TDR response back to a point close to the start of the transmission line effectively allowing to users more accurately to measure the instantaneous or incident impedance of the line.
-
Product
Antenna Impedance Analyzer
TZ-900 AntennaSmith
-
Analysis Parameters: SWR, Complex Impedance, R+jX, reflection coefficient, Smith Chart. 0.2 - 55 MHz• SWR
-
Product
Impedance Monitors
-
Single channel impedance monitorA flexible frequency generator/analyzerSupporting external load/potentiostat - TDI Dynaload RBL488 series & XBL series - WonATech WEL Load - Other 3rd parties potentiostat/galvanostat
-
Product
Impedance Analyzer, 20 Hz to 10/20/30/50/120 MHz
E4990A
-
The E4990A Impedance Analyzer has a frequency range of 20 Hz to 120 MHz. The E4990A provides an industry best 0.045% (typical) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source. The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.
-
Product
High Impedance Differential Module
HID
-
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.





























