product
Single 4x4 1-Pole 16 Amp PXI Power Matrix With Loop-Thru
40-552-011
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
product
One Wire Communication Board
MS 1727
- Digital serial bus communication with low speed data over a single line, Both signaling and driving power over a same single signal.- Protocol used in small inexpensive devices. Such as digital thermometer, weather instruments, laptop sub module, authenticate system and some cell phone battery packs.- Always master only initiates the communication and in overall in charge of the network.- Bus communicates with master and slave at a low data rate of 12kbps.- All terminals in the network are communicating by half-duplex mode.- Maximum of 255 nodes in each 1-wire network- Each data transaction will start with 480micro second low RESET pulse.
-
product
Redundant Frequency and Timing Systems
A unique feature of our frequency standards and distribution amplifiers is that the two separate parts of the redundant system are identical and can easily be inter-changed, for maintenance purposes. What we mean by this is that that we don't have a "Master" unit and a "Slave" unit. Whatever unit is powered up first becomes the master unit and the other becomes the slave unit.
-
product
PXI General Purpose 2A Relay Module 16xSPDT, 78 D-sub
40-131-101
Low cost, general purpose electromechanical relay cards suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include switching of medium power AC and DC loads or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 or 78 pin D-Type connector plug.
-
product
Customer Acceptance Test Panel
TA-65
DGS-65 Customer Acceptance Panel for both testing and trouble- shooting. We have added an option to the panel that allows you to select an analog slaving meter or the LED monitor lights as shown in the maintenance manual Fig. 5-14. The addition of the meter provides the technician with a more visible means to monitor the slaving "trend". The 50 pin DG connector is broken out on the panel to assist in monitoring or isolating unit signals.
-
product
PXI 5A Mux 1-Bank 48-Ch Isolated COM
40-651-011
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
EtherCAT IO Slave For M-Type Modules
ECAT-IO M Series
The ADLINK complete EtherCAT solution, from hardware to middleware to software, with every element tailored for dedicated EtherCAT functionality, includes PCIe-833x and SuperCAT master controllers, ECAT & EU slave systems, and remote monitoring and control providers. As well, ADLINK’s Softmotion one-stop control kernel delivers flexible and easy-to-use intelligent platforms for driving next-generation modern Smart Factories. ADLINK’s ECAT IO system features a modular design for flexible high channel density, rugged construction, easy maintenance, and compatibility with third-party EtherCAT master products. Precise time-deterministic control enables I/O synchronization for critical applications, while the flexible terminal block design supports multiple wiring methods. The ECAT’s unique structural and electronic design supports hot swapping of modules, reducing repair time, and offers full operability from 0°C to 60°C. The ECAT slave system is also fully compliant with the EN 61131-2 standard for shock and vibration and EN 61000-6 for heavy industrial EMC protection, as well as receiving an emission certificate.
-
product
PXI General Purpose 2A Relay Module 16xSPDT, 50 D-sub
40-131-001
These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.
-
product
32-CH Discrete Input Modules with U Profile
HSL-DI32-UD
HSL U series is designed as compact & horizontal-placed slave module. For I/O module, ADLINK adopts three types of connectors to meet different users' requirements & habits. Compared with past models, U series brings compact size, easier-to-wire and cost-effective advantages for users. DI/O, AI/O and motion control module are supported
-
product
16 channel 16 bit Digital to Analog Module
CPCI-DA16-2
The CPCI-DA16 is a slave Digital to Analog board thatis managed by the host processor on the CPCI bus.The card contains a state machine that performs mostof the work of outputting data, in order to minimize theimpact to the HOST system.
-
product
PXI-8531, 1-Port PXI CANopen Interface Module
781061-01
1-Port PXI CANopen Interface Module—The PXI‑8531 is a high-speed CANopen interface for developing applications with the NI‑Industrial Communications for CANopen driver. CANopen is the application layer that sits on top of the CAN physical layer often used for industrial automation applications. It was designed for motion-oriented machine control networks, such as handling systems, but now it is used in a variety of products and applications, including medical equipment, off-road vehicles, maritime electronics, public transportation, and building automation. The PXI‑8531 can transmit/receive process data objects (PDOs) and service data objects (SDOs) according to CiA DS301. It also features a batch SDO editor with electronic data sheet (EDS) file integration and layer setting services (LSS) support for slave node configuration.
-
product
PXI 40Amp 14Volt 2xSPDT Automotive Relay
40-181-001
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
product
PXI 12xSPDT 16A Power EMR Module
40-161-101
This40-161 range of PXI power relay modules is available with achoice of 16 x SPST, 12 x SPST, 10 x SPST, 12 x SPDT and 6 x SPDT power relays, for switching loads up to 16A at250VAC. These Power Relay Modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. The 40-161 is ideal for switching up to 16A in both AC and DC applications.
-
product
Automotive Ethernet Interface Device
The Automotive Ethernet Interface Device converts unshielded twisted pair (UTP) Automotive Ethernet to standard Ethernet. This device is ideal for developing applications that require Automotive Ethernet to test and validate automotive electronic control units (ECUs). It includes ports for Automotive Ethernet connections and ports for 100BASE-TX Ethernet connections. You can use switches on the front panel to configure each 100BASE-T1 port as master or slave. The device also provides LED on the front panel so that you can monitor the linkage and activity on the various ports.
-
product
PXI 20Amp 28Volt 4xSPST Automotive Relay
40-180-111
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
product
IVN-8561, Automotive Ethernet Interface Device
786169-01
2-Channel, 4-Port, 100BASE-T1 to 100BASE-TX Automotive Ethernet Interface Device—The IVN-8561 is an interface that converts 100BASE-T1 unshielded twisted pair (UTP) automotive Ethernet to standard 100BASE-TX Ethernet. It is ideal for developing applications that require automotive Ethernet to test and validate automotive electronic control units (ECUs). The IVN-8561 provides two channels to convert data between 100BASE-TX Ethernet and 100BASE-T1 Automotive Ethernet. Each 100BASE-T1 port can be configured as master or slave, using switches on the front panel. The IVN-8561 also provides LED on the front panel so that you can monitor the linkage and activity on the various ports.
-
product
PCI-8531, 1-Port, CANopen Interface Device
781060-01
The PCI‑8531 is a high-speed CANopen interface for developing applications with the NI‑Industrial Communications for CANopen driver. CANopen is the application layer that sits on top of the CAN physical layer often used for industrial automation … applications. CANopen was designed for motion-oriented machine control networks, such as handling systems, but now it is used in a variety of products and applications, including medical equipment, off-road vehicles, maritime electronics, public transportation, and building automation. The PCI‑8531 can transmit or receive process data objects (PDOs) and service data objects (SDOs) according to CiA‑DS 301. It also features a batch SDO editor with EDS file integration and LSS services support for slave node configuration.
-
product
Ethernet to Modbus RTU Interface
Model 9099
* Use Modbus TCP/IP, VXI-11, or Raw Sockets (Telnet) or to control Modbus RTU slave devices.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Interfaces with PLCs or any Modbus TCP/IP Controller.* Fully VXI-11 compliant.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the Modbus network or devices.* 9099 is a 2x to 5x faster than the 8099 and includes a new Modbus device control page.
-
product
MIPI Soundwire Total IP Solutions
Soundwire
Soundwire is suited for small, cost-sensitive audio peripherals such as modern digital class-D amplifiers and digital microphones. The Total MIPI SoundWire IP Solution from Arasan enables early adopters the fastest path to adoption of this new standard by offering a comprehensive IP package that includes the Verilog RTL source code for Master and Slave, fully validated for compliance with the standard, a comprehensive test environment with a compliance suite for verification of the IP package, a SoundWire Hardware Development Kit (“HDK”) for FPGA prototyping, a SoundWire protocol analyzer and a complete SoundWire software stack.
-
product
8x4 Power Matrix, 2-Pole, 2xGMCT
40-550-902
This version of the 8x4 power matrix is for heavy current/low duty cycle power switching. Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current.
-
product
16-CH Discrete Input 16-CH Discrete Output Module
HSL-DI16DO16-M-NN
- Input voltage: ±40 V (Max)- Output switching capacity: Single channel 500 mA; all channels 60 mA at 24 VDC- Photo couple isolation voltage: 2500 Vrms- Input impedance: 4.7 KΩ- Input current: ±10 mA (Max) , ±12.5 mA (Peak)- 16-CH digital input and 16-CH digital output. "NN" type for NPN sinking type sensor input or dry contact and NPN sinking type output- Slave ID consumption: 1
-
product
32-CH Discrete Input Modules
HSL-DI32-M-N/HSL-DI32-M-P
- Slave ID consumption: 2 consecutive from odd- "N" type for NPN sinking type sensor or dry contact; "P" type for PNP sourcing type sensor or wet contact- Photo couple isolation voltage: 2500 Vrms- Input impedance: 4.7 KΩ- Input current: ± 10 mA (Max), ± 12.5 mA (Peak)- Input voltage: ± 40 V (Max)- LED indicator: Power, Link and Input status- Power supply: +10 V to +30 VDC
-
product
PXI General Purpose 2A Relay Module 19xDPST
40-132-202
Pickering Interfaces 40-131/132 modules are a range of low cost, general purpose electromechanical relay cards. They are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.
-
product
Modbus Analog Output Modules
DAT3020 Series
The DAT3020 series from Datexel is a range of Modbus analog output cards. These cards or modules have both voltage and current outputs either 0-10V or 4-20mA and are isolated from the input, output and power supply. They are available with either 2, 4 or 8 channels. The DAT3011 is a Modbus slave with 2 analog inputs (Thermocouple, RTD's mA, Resistance, Potentiometers, mV and voltage) and 2 analog outputs(4-20mA). It also has 3 digital inputs and outputs. Combining these analog output cards with the analog input cards, and the digital IO cards with the DAT9000 controllers make Datexel the smart choice where Data Acquisition is needed.
-
product
PXI 5A Power MUX, 1-Bank, 48-Channel
40-651-001
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel 4-bank. 11-channel 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI 5A Power MUX, 8-Bank, 5-Channel
40-651-004
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
2-CH Pulse-Train Motion Control EtherCAT Module
EPS-7002
ADLINK" s EPS slave system features modular design for flexible high channel density, rugged construction, easy maintenance, and intelligent performance, compatible with 3rd party EtherCAT products. Precise time-deterministic control enables I/O synchronization for critical applications, and FPGA and ARM technology allow users to fully monitor status of EPS modules and systems, including operating temperature and usage cycle of relay switching, as well as motion control status for general purpose motor drive control. In addition, the ADLINK EtherCAT configurator enables auto-scan and configuration across EtherCAT systems. The EPS" unique structural and electronic design supports hot-swappable function, reducing repair time, and the rugged construction and operating temperature range of -20°C to 60°C allow operation in the harshest environments.
-
product
Modbus Master TCP/IP Component for .NET
WSMBT
WSMBT is a powerful and simple to use .Net component that makes it easy to access data from a Modbus slave device connected to the PC's Ethernet network. Simply drop the component on your form and talk to your device with your VB.NET, C# or Managed C++.
-
product
Programmable Modbus Simulator
ModMultiSim
ModMultiSim is a programmable Modbus simulator that enables realistic simulation of multiple Modbus slaves in their environment. Connect your Modbus masters to ModMultiSim, instead of real Modbus slave devices, in order to test and configure the masters.
-
product
PXI 20Amp 28Volt 2xSPDT Automotive Relay
40-181-011
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC. The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.