GHz Synthesizers
See Also: GHz
-
product
PXI/PXIe Microwave Multiplexer, Single SP8T, 40 GHz, 50 Ω, SMA 2.9, Terminated
40-788-051-T
The 40-788-051-T (PXI) and 42-788-051-T (PXIe) are single SP8T 40 GHz microwave multiplexers with automatic termination of unused signals.
-
product
WaveRunner Oscilloscope, 4 GHz Bandwidth, 4 Input Channels, 40 GS/s on 2 Ch Sample Rate
WaveRunner 9404M
4 GHz, 40 GS/s, 4ch, 64 Mpts/Ch DSO with 15.4" Capacitive Display.
-
product
Streamline USB Vector Network Analyzer, 44 GHz
P5007A
Compact, faceless, USB vector network analyzer (VNA). Flexible two port VNA which dramatically reduces your size of test. Up to 44 GHz.
-
product
Streamline USB Vector Network Analyzer, 26.5 GHz
P5005A
Compact, faceless, USB vector network analyzer (VNA). Flexible two port VNA which dramatically reduces your size of test. Up to 26.5 GHz.
-
product
PXIe 8 Bit High Speed Digitizer - 2.5 GS/s on 2 Channels, 1.5 GHz Bandwidth
M4X.2221-X4
The 9 models of the M4x.22xx-x4 Express series are designed for the high speed data acquisition. Each of the input channels has its own A/D converter and its own programmable input amplifier. This allows the recording of signals simultaneously on all channels without any phase delay between them. The extremely large on-board memory allows long time recording even with the highest sampling rates.
-
product
SP4T RF Pin Diode Switches To 16 GHz
The 4-way series of absorptive and reflective switches operate from 100 MHz to 16 GHz. They are rated at 200 mW maximum input power and have a switching time of 100 ns. SP4T switches that operate up to 8 GHz have a maximum VSWR of 1.6:1 and minimum isolation of 60 dB. All absorptive and reflective switches manufactured by Pulsar Microwave require both positive and negative 5-volt supplies. Additionally, the TTL control logic operates from 0 to +5 VDC. Voltage connection is made with feed thru terminals. Ground connection is made through the chassis and turret terminals.
-
product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-788-121-E
The 40-788-121-E (PXI) and 42-788-121-E (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
product
WaveRunner 9254M-MS (2.5 GHz Bandwidth, 4+16 Input Channels, 40 GS/s on 2 Ch Sample Rate
WaveRunner 9254M-MS
2.5 GHz, 40 GS/s, 4ch, 64 Mpts/Ch Mixed Signal Oscilloscope with 15.4" Capacitive Display.
-
product
PXI/PXIe Microwave Multiplexer, Single SP8T, 18 GHz, 50 Ω, SMA, Failsafe
42-788-021
The 40-788-021 (PXI) and 42-788-021 (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T configurations with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
product
PXIe Vector Network Analyzer, 10 MHz To 44 GHz
M9837A
The M9837A PXI network analyzer (VNA) offers unrivaled performance for testing multiport, multisite, multi-DUT modulated signal measurement from 10 MHz to 44 GHz.
-
product
Temp Characterized CalPod, 20 GHz
85531B
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards. Very useful in thermal chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the thermal testing to perform a normal re-calibration.
-
product
Coaxial Waveguide Adapter, 2.4 mm (f), 26.5 to 40 GHz
R281A
The Keysight R281A adapter transforms waveguide transmission line into 50-ohm coaxial line. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
product
PXI-2596, 26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module
778572-96
26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2596 is an RF signal multiplexer switch with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use the PXI‑2596 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
WaveRunner Oscilloscope, 2.5 GHz Bandwidth, 4 Input Channels, 20 GS/s on 2 Ch Sample Rate
WaveRunner 9254
2.5 GHz, 20 GS/s, 4ch, 16 Mpts/Ch DSO with 15.4" Capacitive Display.
-
product
110 GHz, 1.0 Mm (m-f) Test Port Cable 10 Cm
11500JK10
Connect test ports to devices, fixtures, or probe tips with this 10-cm cable
-
product
PSG RF Analog Signal Generator, 100 kHz to 9 GHz
E8663D
Tackle demanding radar & satcom measurements with metrology-grade performance, including high output power & superior level accuracyUse as an ideal reference in phase noise test systems or for analog-to-digital converter testing with the lowest phase noise in a commercial sourceCharacterize devices & circuits by adding AM, FM, M & pulse modulation to your signalImprove existing test system performance: E8663D is built on the outstanding legacy of the 8663A & is fully code compatible
-
product
SA1000X, 1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784255-01
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
PXI/PXIe Microwave Multiplexer, Single SP6T, 67 GHz, 50 Ω, SMA-1.85, Failsafe
42-785C-571
The 40-785C-571 (PXI) and 42-785C-571 (PXIe) are single failsafe SP6T 67 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
MXA Signal Analyzer, Multi-touch, 10 Hz to 50 GHz
N9020B
Quickly adapt to evolving test requirements of wireless devices Shorten test times with hardware-accelerated power measurements, rapid display updates and marker peak searches and fast sweeps Simplify testing with one-button measurements from X-Series applications Capture elusive or transient signals with full-band real-time spectrum analysis
-
product
Modulation Distortion Up To 125 GHz
S930712B
S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
PXI/PXIe Microwave Multiplexer, Single SP8T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
42-788-021-T
The 40-788-021-T (PXI) and 42-788-021-T (PXIe) are single failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
product
PXI/PXIe Microwave Multiplexer, Single SP4T, 18 GHz, 50 Ω, SMA, Failsafe
42-785C-421
The 40-785C-421 (PXI) and 42-785C-421 (PXIe) are single failsafe SP4T 18 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
Adapter, 2.4 mm (f) to APC-7, DC to 18 GHz
11902B
The Keysight 11902B is a metrology grade, 2.4 mm female to APC-7 adapter with dc to 18 GHz operation.
-
product
PXI/PXIe Microwave Relay, Dual SPDT, 110 GHz, 50 Ω, SMA-1.0, External Termination, Latching
42-781A-922-LA
Externally terminated switches have the advantage that the terminations can be removed and replaced with higher power RF loads. This also allows alternative configurations such as terminated 4-port bypass (1 termination removed) and 5-port DP3T (both terminations removed). See the datasheet for diagrams of these configurations.
-
product
SNS Series Noise Source 10 MHz to 18 GHz (ENR 6 dB)
N4000A
The SNS series N4000A noise source is designed for accurately measuring devices with low noise figure, with a frequency range of 10 MHz to 18 GHz and nominal ENR 6 dB.
-
product
PXIe, 2-Channel, 10 GHz PXI Optical to Electrical Converter
786544-01
PXIe, 2-Channel, 10 GHz PXI Optical to Electrical Converter—The CohSol O2EPXIe-1001-2 provides two DC-coupled photoreceivers that convert light with wavelengths from 750 nm to 1,650 nm into electricity at speeds up to 10 GHz. It offers multimode fiber with a 62.5 µm core and SC/PC, FC/PC, SC/APC, or FC/APC connectors. The CohSol O2EPXIe-1001-2 is ideal for reliable testing in manufacturing or research and development environments.
-
product
Modulation Distortion Up To And Beyond 125 GHz
S930713B
S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Comb Generator, 10 MHz to 50 GHz
U9391F
The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
product
PXI/PXIe Microwave Relay, Dual SPDT, 18 GHz, 50 Ω, SMA, External Termination, Failsafe, Remote Mount
40-781A-122-E
The 40-781A-122-E (PXI) and 42-781A-122-E (PXIe) are dual SPDT failsafe 18 GHz microwave relay modules with external terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
product
Solid State FET Transfer Switch, 300 KHz To 18 GHz
U9400C
Offers outstanding performance in isolation, switching speed, and video leakage over a broad operating frequency range