Filter Results By:
Products
Applications
Manufacturers
Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
Calibration Kit YAV90MMU
YAVMMUCK
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
product
Process Calibrators
4-20mA Process calibrators are specific equipment which, thanks to the employed modern building technology, is now part of the range of mobile devices which have become indispensable to technicians working on modern installations.
-
product
Documenting Calibrators
We offer documenting calibrators, for us the “documenting” calibrator means a calibrator that can store the calibration results into its memory and upload them to calibration software. This benefits you as you don’t need to carry pen and paper and spend time in making notes and typing them into software.
-
product
Testwave Calibration
Testwave® LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send you recall notices before your equipment calibration expires, and if we don’t hear from you, we will call, to make sure you stay in compliance with your calibration requirements. Calibrations are performed at your facility, or at our Sparks Nevada laboratory.
-
product
Thermocouple Calibration Furnace
9118A
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
product
X, Y, Θ Position Calibration Plate For Machine Vision and Microscopy
nanoGPS OxyO Scale
nanoGPS OxyO® Scale is a position calibration plate for Machine Vision and Microscopy, available as OEM or stand-alone solution from HORIBA Scientific.nanoGPS OxyO® technology is based on taking a picture of a patented patterned substrate, and interpreting this picture into position (x, y) and orientation (θ). The nanoGPS OxyO® Encoder is also based on this technology.
-
product
Pressure Calibrators
AMETEK Sensors, Test & Calibration
Our pressure calibrators offer a wide variety of features, accuracies, and pressure ranges. Included are intrinsically safe percent of reading calibrators, reference data recorders, wide-range dual sensor calibrators, and calibrators with built in pressure pumps. Many of our calibrators also offer current measurement, voltage measurement, 24 volt loop power supplies, and even complete systems with pressure pumps and calibration software. In many cases, one handheld calibrator can replace multiple instruments, reducing ongoing recalibration and maintenance costs.
-
product
Multifunction Calibrators
These field and bench calibrators source, simulate, and measure pressure, temperature, and electrical signals with exceptional precision. They can automate calibration procedures, store data, and even calibrate and troubleshoot HART-compatible devices. Our bench calibrator can even be used to calibrate our field calibrators. Also find here 5.5- and 6.5-digit bench multimeters for to assist with a variety of general test and calibration applications.
-
product
AC Calibration Standard
1U647-001
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
product
Emissions Reference Source
ERS
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
product
Automated AC Digital Hipot Tester
Educated Design & Development, Inc.
1 button testing - No setup required, just plug right in! Or, make a plug for your cordless product, and plug right in! EASY!Easy to identify PASS / FAIL visible and audible indicationAuto Test Time (1 sec. / 60 sec.)+ - No need to set a timer or clock watchSafety Protected Start Switch -- Protects user from shock!Performs the Low Current Ground Continuity test at the same timeMeets UL, CSA, CE, EN, IEC, MIL and all other international safety agency requirements as well as UL 120Kohm requirementsIncludes ISO/IEC 17025 Accredited Calibration Certificate, accredited by ACLASS (Internationally accepted results... equivalent to A2LA)
-
product
Spectroradiometers
Spectralradiometer are spectrometer with an absolute radiometric calibration.
-
product
Radiator Flow Test Machine
8601
The Radiator Flow Test Machine P/N 8601 meets all requirements of military specification MIL-F-45955A (AL). It is completely self contained and requires only connection to a source of shop electrical power to place in operation. A power cable complete with three prong grounding plug is permanently attached to the machine for this purpose. The unit consists of a water storage tank, a pumping system, a flow measuring system, a support and workstation, and the required hose adapters for connection to different size radiators. The complete unit is mounted on swiveling casters. The flow rate is infinitely adjustable from 0 to 120 gallons per minute by means of a panel mounted control valve. The machine is constructed from heavy 10 gauge steel, is double welded and is coated externally and internally with a water-resistant epoxy coating. Flow measurement is accomplished by a digital panel meter with a calibrated accuracy of plus or minus 3 percent of scale between 5 and 120 gallons per minute. Higher flows available on request.
-
product
AE Valve Leakage Detector
SVLD1
Through acquisition, processing, and calculation of acoustic emission signal of the valves, SVLD1 could generated root-mean-square voltage (RMS), average signal level (ASL) and power (P) parameters as which could judge the leakage. Meantime, you can pre-calibrate the leakage quantity for the specified valve, and calibration curve of parameters and leakage could be calculated by SVLD1, so as to give the valve leakage reference value during the test.
-
product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
product
Voltage Calibrators
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
product
Standard Current Transformer
HL / 640
Wuhan Huatian Electric Power Automation Co., Ltd.
It is used as the calibration standard of current transformer in the error test of transformer.
-
product
Sound Level Meters and Calibration
PeakTech Prüf- und Messtechnik GmbH
This digital sound level meter is designed for noise projects, quality control and all kinds of measurements of ambient sound, as well as for sound measurement in factories, schools, offices, in traffic , Household and much more used.
-
product
Torque Instrument
DTR is a microprocessor based digital indicator, totally autonomousand with input for strain gauge based torque transducers.A ≤±0,02% accuracy makes it possible to be used use in qualitysystems as first or second line sample, periodically calibrated by aSIT center. Measuring system consists of a particularly long-termstable analogue section, of a carrier frequency amplifier whichminimises thermal drifts and of a 16 bits A/D converter whichensures 65.000 internal divisions.
-
product
Nitrate Ion and Nitrate-Nitrogen Concentrations Pocket Water Meter
LAQUAtwin NO3-11C/NO3-11S/NO3-11
The only pocket meter that directly measures nitrate ion and nirate-nitrogen concentrations in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.
-
product
6.5 and 7.5 Digit Multimeters
Truevolt Series
Truevolt digital multimeters (34460A, 34461A, 34465A, 34470A) enable you to get quick insights, measure low-power devices, and maintain calibrated measurements with Keysight’s new patented technology. Truevolt offers a full range of measurement capabilities with higher levels of accuracy, linearity, speed, and resolution.
-
product
Laser Power Sensors
Make accurate laser power measurements, from the deep UV to the infrared, with these calibrated, traceable sensors.
-
product
acA4096-11gc, Color GigE Vision, 9 MP, 11 FPS Area Scan Camera
787061-01
The acA4096-11gc is a Color Basler Ace GigE Vision Camera with a 9 MP resolution and a maximum image acquisition speed of 11 frames per second. The acA4096-11gc uses a IMX267 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.
-
product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard DUO
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.2 axis design for rotary tilting applications with self-locking worm gearing and a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
product
Torque Meters
Torque meter is available in two different versions: handheld meters or tabletop meters. Torque meter have a wide range of applications. Handheld torque meter is mainly used for industry while tabletop torque meter is the ideal tool for laboratories. Our Torque meters come with a RS-232 port to transfer torque values to a PC or a portable computer. This is very helpful if you want to save the data and stand the chance to compare what you have measured afterwards. Another possibility is that you aim to do long-term-measurements. There the interface and the software are two very useful features that are given to you.Tabletop torque meters can be equipped with a printer (option). You can also order a ISO calibration certificate as an option. This ensures that the device has been calibrated and works perfectly including a measurement with only small deviances that can still be tolerated and do not influence the product's functions. We can offer you torque meters that can measure up to a maximum measuring value of 500 Nm.
-
product
Enhanced Time-Domain Analysis With TDR
S95011B
This application enables the analyzer to perform enhanced time domain analysis for high-speed data applications. All functionality of the S95010B are included (TDR/TDT mode). In addition, the S95011B enables more detailed measurements and evaluations, such as eye-diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S95011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, mechanical calibration kits or ECal with DC option (i.e., N469xD or N4433D with Option 0DC) are recommended.
-
product
Load Cell Indicator
9840
The 9840 is suitable for use in calibration labs, field service, or anywhere high accuracy is important. Features include a bipolar 6-digit 2-line display, remote sense, low noise, 22-bit resolution, USB port with RS232 communication, mV/V calibration and the ability to store up to 25 different sensors. 6-point linearization, unit conversion, front-panel tare. Self calibration via TEDS Plug & Play ready IEEE1451.4 compliance.