Jumpers
-
Product
Deci-Center™ Jumpers
SERIES 150/151
-
DECI-CENTER JUMPERS. Pitch bars help maintain .100 [2.54] conductor spacing.Consult factory for jumper lengths under the specified minimum length.
-
Product
Load-to-Line Jumpers
200
-
TESCO’s Load-to-Line Jumpers (Catalog No. 200) allows the utility to perform meter maintenance without interruption of service to the downstream occupant. TESCO bypass jumpers are rated for 200 amps continuous duty and are made from a durable 1/8″ thick tin-plated copper with a durable insulating material covering everything except the blades.
-
Product
n-Line Jumpers on 0.100 [2.54] Centers
Series 152, 156 & 157
-
In-Line Jumpers on .100 [2.54] Centers. End connectors have Gold plated, solid Brass pins on .100 [2.54] centers. Available single-ended (Series 156), double-ended (Series 157), or bare-ended (Series 152). Reliable, electronically tested solder connections.
-
Product
25 Pin Breakout Interface
VSI-Breakout-25
-
The VSI-Breakout-25 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
Product
Switch Modules - 16 Two Pole Relays Arranged as an 8x2 Matrix
JX16/AB-2
Switch Module
This module has 16 two pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 two pole matrix. It is available with Type S, M or LT reed relays for high speed, long life application.
-
Product
Economy Model Vertisocket™
Series 800 and 822
-
Thrifty Model Vertisockets with Bifurcated Contacts. These low cost VertisocketsTM are recommended for high volume vertical display mounting applications. Very useful for connection of board-to-board jumpers and for DIP switches as well as LED devices.
-
Product
I/O Input/Output Board
VME-4514A
-
The VME-4514A Analog I/O (AIO) Board provides 16 high-quality analog output channels which can be programmed with on-board jumpers to operate in a variety of voltage ranges. Each output can source or sink 10 mA at ±10 V. For off-line testing, the analog outputs can be disconnected from the I/O connector.
-
Product
Connector Adapter
-
MCA-ST connector adapter for the connection of micro plugThe connector adapter allows the direct connection of fine-pole connectors on circuit carriers or jumpers. The adapter is guided over the connector housing, which overcomes the tolerances of carrier and mounting.
-
Product
DIP-ER™ Logic Jumper
Series 115, 116, & 117
-
DIP-ER Logic Jumper. Reliable, electronically tested solder connections. Protective covers are ultrasonically welded on and provide strain relief for cables. DIP-ER Logic jumper wiring is point to point. Consult factory for other wiring needs.
-
Product
PCI POST Code Display
post4d
-
During power on self-test (POST), most PC BIOSes will write diagnostic codes to port 80h or port 84h (jumper selection). Use post4d to display these codes on a dual digit LED display. Additional LEDs indicate the status of the power supply rails. Convenient business card size.
-
Product
Flat Pin-Staked Flex Jumpers
Series 171 thru 173
-
Flat Pin Staked Flex Jumpers. Aries Flat Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors embedded between layers of tough, flexible, flame- retardant insulation.
-
Product
Tiny AVR Programmer
-
The ATtiny45 and 85 are a couple of really cool little MCUs but did you know you can program them in Arduino? That's right, now you can shrink your Arduino projects down to "tiny size" by moving your code straight over to these small but capable ICs. The standard method for programming the ATtiny ICs involves a breadboard, lots of jumper wires and a hardware programmer, but David Mellis over at MIT Media Lab has simplified the process by laying out this handy USB programmer.
-
Product
Switch Modules - 32 Single Pole Relays Arranged as a 16x2 Matrix
JX32/AB-1
Switch Module
This module has 32 single pole relays arranged as a 16x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 16x2's per chassis, or jumpered to the backplane to form up to a 256x2 matrix. It is available with Type S or M reed relays for high speed, long life application.
-
Product
MPO / MTP® Patch Cords
-
Multi-fiber jumpers and loopbacks deliver the performance and reliability needed in todays’ demanding high-speed broadband and data networks.
-
Product
Multiple 12/16 Channel Latch/Compare Trigger Function
PCI-1274
-
Encoder input is 4 MHz for 4xAB mode, 1 MHz for CW/CCW modePulse output up to 1 Mpps and the output type can be switched to differential or single-end by jumper settingSupport velocity motionSupports speed overrideSupports T/S-curve and programmable acceleration/deceleration rateSupport 16 Home modesSupport programmable interruptLatch and Compare max. frequency up to 1kHzPCI-1274-12AE support 12-ch latch and 12-ch Compare functionPCI-1274-16AE support 16-ch latch and 16-ch Compare function
-
Product
Switch Modules - 16 Single Pole Relays Arranged as an 8x2 Matrix
JX16/AB-1
Switch Module
This module has 16 single pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.
-
Product
Fiber Shaker
MPX-SR3
-
Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.
-
Product
1310/1550 nm Dual Laser Source Back Reflectiom/Power Meter
GM8019 + GM83001E
-
The UC INSTRUMENTS GM8019 + GM83001E 1310/1550 nm dual laser source back reflection meter and power meter is a compact, direct display instrument for the convinent measurement of backreflection, insertion loss and power connector, fiber optic components, and system. With a single output port, the meter is very easy to use and ideal for fiber cable jumper manufacturers.
-
Product
8-CH 12-Bit Isolated Analog Output Cards
PCI-6308 Series
Analog Output Module
- Supports a 32-bit 5 V PCI bus- Isolated 8-CH 12-bit voltage output- 2500 VRMS optical isolation- Jumper selectable bipolar and unipolar output ranges- 4-CH isolated DI and 4-CH isolated DO- Current output version available on PCI-6308A
-
Product
VME Analog Output Module
DP-VME-2115
-
DP-VME-2115 is an industrial standard 24 channel D/A (Digital to Analog) board. It incorporates most of the features which are demanded in industrial applications. Each Digital to Analog Converter (DAC) is provided with a separate reference voltage selection either from internally generated reference or from the external input. This external input reference signal is passed into the protection circuits before it is fed to any active components. The input protection circuit is designed for ± 25Vp-p input ranges. The DAC output may be unipolar or bipolar and the output is jumper selectable, which is routed to the VME P2 connector, with short circuit protection of upto 30mA.
-
Product
Deluxe Relay Test Set
60660
-
Jumpers have tabs for clamping and flat pads to place test leads on. No need to pierce wires or connect multiple jumper wires. Also Includes Test Lead Kit for easily and securely connecting Relay Test Jumpers to a multimeter. Jumper wire may be used between common and open to close the relay circuit for testing and has a test port to easily check voltage. Also provides access for a clamp-on amp meter. Relay Puller Pliers easily remove electrical relays without damage to the relay or electrical box.
-
Product
Optical Extended CAN Bus Jumper
EOFL-C
-
Optical Extended CAN Bus Jumper, using fault tolerant to optical conversion to extend the range, can extend up to 5 kilometers subsea.Qualified repeater housing protected on each side by highly reliable glass to metal sealed penetrators.
-
Product
Low PIM Cable Assemblies
-
Low-PIM jumper cables feature a maximum PIM level of -155 dBc and are made with UL910 plenum-rated SPP-250-LLPL cable. The PIM levels of each cable have been fully tested with the results of those tests marked on each cable. These Low-PIM cables boast a maximum operating frequency of 6 GHz and a maximum VSWR of 1.25:1 up to 2 GHz and 1.35:1 up to 6 GHz. These Low-PIM cables are lightweight, flexible and have an operating temperature range of -55°C to +125°C and are available with 4.3-10, 7/16 DIN, N and 4.1-9.5 mini-DIN connector combinations, including right-angle connectors.
-
Product
3U OpenVPX High Density Multifunction I/O Board
68CB6
Multifunction I/O
The 68CB6 is a Configurable Open Systems Architecture™ (COSA®) 3U OpenVPX™ board that is preconfigured with 10 different “inboard” I/O, measurement and communication functions. This Combination-function Board (CB) provides a full suite of some of the most common & useful function interfaces supporting many different applications. The 68CB6 features a wide but dedicated selection of functions: Standard Functionality Discrete I/O (DT1); Successive Approximation Register (SAR) ±100 V Analog-to-Digital (AD); Isolated High Voltage Analog-to-Digital (ADF); ±10 V Digital-to-Analog (DA); Thermocouple (TC1) or Resistance Temperature Detector (RT1); Full-bridge Strain Gauge (SG1); Transmission/gear box Chip Detection and Fuzz Burn (CD1); LVDT-to-Digital linear (LD6) displacement (position) measurement, AC Reference Source output (AC2); CAN bus communication (CB8). The 68CB6 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for external intermediate circuit considerations such as pull-up resistors or mechanical configuration jumpers. Inboard functions are software controlled and memory addressed, accessed in similar COSA® modular fashion to maintain seamless common NAI Software Support Kit & API/library structures.
-
Product
PXI Dual 0-30VDC Programmable Power Supply
TE3200
-
The TE3200 is a dual output programmable DC power supply designed for use in PXI/CompactPCI chassis. The TE3200 occupies a single slot and will utilize an external supply of 48VDC (provided). A separate srrew-terminal/power adapter board, p/n TE3202, provides connectivity for two 48VDC power suppies and screw-terminals and jumpers for voltage and sense selection and connection. The TE3202 is included with all retail purchases (not included with OEM purchases).
-
Product
Pin-Line™ Vertisocket™
Series 0517
-
Pin-Line Vertisockets. For mounting components, jumpers, etc., at right angle to PC board. Available 1 to 25 positions; cuttable to any number desired.
-
Product
Jumper Cables For Multiport Configuration Of M937xA PXI VNA
Y1242A
-
Use Keysight Y1242A Jumper Cables for multiport configuration of the M937xA PXI Vector Network Analyzer (VNA).
-
Product
Connectors, Jumper - Black
INT-10901
-
Jumper for 0.1" (2.54mm) spaced headers. These are also known as a 'shunt'. These mate with the 0.1" square-pin headers and are the 'open' frame style. RoHS compliant.
-
Product
9 Pin Breakout Interface
VSI-Breakout-9
-
The VSI-Breakout-9 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
Product
128 Channel Isolated Digital Input / Interrupt Module
DP-VXI-3117
-
DP VXI 3117 provides 128 isolated channel digital inputs for sensing DC levels and edge transitions of upto 48VDC. The input level selection for 5 (TTL / CMOS compatible), 12, 24 or 48V is made through on-board jumper selection. The debounce feature is programmable for a period of 2msec to 2147 sec. in binary increments. Channel groups 1 to 32, 33 to 64, 65 to 96 and 97 to 128 can each have a unique programmed debounce period, provided the ratio of clock period between groups does not exceed 32,768.