Device Under Test
a specific purpose component or module check; ex. substantial component of a PCB.
See Also: DUT, Unit Under Test, EUT
-
product
HIGH FREQUENCY DC BIAS
6565 SERIES
The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.
-
product
Regenerative Power System, 1000 V, ±60 A, 20 KW, 400/480 VAC
RP7972A
The RP7972A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
product
Memory Test Software
Teradyne’s customers count on us for our Near Device Under Test (DUT) technology that gives memory device manufacturers a guaranteed performance advantage. A brief description of dynamic memory and storage memory devices will highlight why device manufacturers depend on Teradyne’s memory test solutions.
-
product
Mass Interconnect
Mass interconnect is a way of connecting test instrumentation to a device under test (DUT). To put it simply, mass interconnect is a very large plug and socket which connects your device under test to your test instrumentation without the mess and hassle of having to connect each signal separately.
-
product
GONIOPHOTOMETRY
Goniophotometers are required to measure angular resolved distributions of photometric or colorimetric quantities, either by rotating the lighting device under test or by moving the sensor around the device. Depending on the application, different geometries are used to obtain distributions in the appropriate CIE coordinate system.
-
product
Regenerative Power System, 80 V, ±125 A, 5 KW, 400/480 VAC
RP7942A
The Keysight RP7942A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
product
Test Connector Components
Any flat substrate, or bumped substrate, can be compressed against Z-Axis Elastomeric Connectors to make contact. The picture illustrates a Z-Thru Z-Alloy Connector Frame used to connect the DUT (Device Under Test) to a circuit board.
-
product
Test Port Adapter Set, 3.5 Mm (Test Port) To Type-N
85130C
The Keysight 85130C test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a 3.5 mm to type-N male adapter and a 3.5 mm to type-N female adapter. The frequency range for these adapters is dc to 18 GHz with a return loss of 28 dB or better.
-
product
PXI Programmable Power Supply
PXI Programmable Power Supply modules feature multiplechannels that you can combine for higher voltage or current capabilities. Some modules include isolatedchannels and an output disconnect functionality that allows isolation from the device under test(DUT) when not in use and remote sense to correct for losses in system wiring. You can use these models to simplify the task of designing automated test systems for a wide range of applicationsfrom aerospace and defense to automotive and component testby eliminating the need to mix multiple instrumentation form factors in a given test system.
-
product
Three-Phase Electric Power/Energy Calibrator
MC133Ci
The MC133Ci model is a compact one-housing three phase electric power/energy calibrator. It can supply the device under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
product
Keysight Dual 4x16 Armature Matrix for 34980A
34932A
The Keysight 34932A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x16, 8x16, or 4x32 configurations 128 2-wire cross-points 300 V, 1 A switch; 2 A carry current Connections to the internal DMM Latching armature relays, with relay counter Expandable via four 2-wire analog buses
-
product
Multi-Channel Attenuation Control Unit (5-channels), DC to 6 GHz, 0 to 121 dB, 1 dB Step
J7205A
The J7205A is a multi-channel (5-channels) attenuation solution for signal attenuation and conditioning of up to5 devices under test (DUT). Operating frequency from DC to 6 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7205A reduces cost of ownership and provide the best measurement accuracy.
-
product
2-Module ICT System, I317x Series 6
E9902G
Keysight's family of i3070 Series 6 In-Circuit Test (ICT) systems are built on a proven technology foundation, and they improve test efficiency with time-tested software, hardware, and programmability. I3070 Series 6 ICT tester supports a wide range of printed circuit board assembly (PCBA) sizes for applications including IoT and 5G, as well as automotive and energy. The i3070 features a unique design that delivers the shortest signal path between measurement circuitry and devices under test to minimize undesired effects from parasitic capacitance, improve immunity to crosstalk, and eliminate stray signal coupling effects, delivering consistent and repeatable measurements. The Series 6 is fully backward compatible with previous systems and makes highly repeatable measurements.
-
product
RF Device Tester
RF ITS
Sterner's automated test management system, combined with integrated RF technology modules, provides full functionality, including: Apply power to the device under test (DUT). Read and write blocks of data to set up and validate product EEPROM using a hard-wired communications interface. Scan transmitting devices or traveller barcodes and write the information to the DUT (the "sign-up process"). Inject an RF signal of known frequency and power level to test receiver sensitivity.
-
product
Test Probes
A physical device used to connect electronic test equipment to a device under test (DUT).
-
product
Functional Test
xUTS
Extend test to encompass copious test points and DUT varieties along with real-time, hardware-in-the-loop and other state-of-the-art instrumentation. extendedUTS (xUTS) is a custom product for high complexity functional test. Configured for the unique needs of a class of devices under test (DUTs), the xUTS employs our universal test system approach that combines the best open platform instrumentation and software along with mass interconnect technology.
-
product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-01
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
product
Regenerative Power System, 160 V, ±125 A, 10 KW, 200/208 VAC
RP7936A
The Keysight RP7936A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
product
PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays
M9120A
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
product
NI-9228 , ±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783861-02
±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9228 performs differential analog input. With channel-to-channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9228 is simultaneous sampling with two options for filtering: a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
product
RSE Wireless EMC Spurious Emission
TS8996
The R&S®TS8996 RSE test system is designed for EMI and radiated spurious emission testing on wireless devices in semi-anechoic or fully anechoic chambers. The modular design makes it easy to extend the system to include new communications technologies. Typical devices under test include mobile phones or radio sets along with radiated measurements of other short-range devices. Standards require a wide range of test setups and a wide and high frequency range (up to 40 GHz). ESW or FSW frequency ranges are extended up to 325 GHz with option B21 using receive units TC-RSE for 5G FR2. Dedicated RSE test routines are also covered for this frequency range.
-
product
PXI Battery Simulator Module
41-750-001
The 41-750 is a battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
product
PXI Dual 18 Channel MUX, 96-Pin SCSI Connector
40-735-912-S1
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
DUT Prototype Board
DPB8800
The DPB8800 is an 11? x 14? PC board used to interface the tester with the Device Under Test (DUT). This board contains generous area for custom circuitry and extra relays. The DPB8800 is also available with standard solutions to test families of components like Op-Amps, Regulators, ADC?s and DAC?s. +/-15 V and +5 V are available to support circuitry biasing.
-
product
1kV, 120 MHz High Voltage Differential Probe Without Tip Accessories and with Auto Zero Disconnect
HVD3106A-NOACC
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
PXI-2549, 2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module
778572-49
2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2549 is a general-purpose single‑pole double‑throw (SPDT) switch module. You can use it to add flexibility to your switch network or to maintain uniform signal paths across multiple channels when building high‑channel‑count multiplexers. The PXI‑2549 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
Bulk Current Monitoring Probe
MP-50
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
product
Digital Leakage Current Tester
Educated Design & Development, Inc.
Fast - All operator controls are located on the front panel to expedite testing. The entire test can be performed in a matter of seconds! Pays for itself in time and stress savings. Versatile - Measures Leakage Current in accordance with UL, CSA, EN, and IEC/ International Standards. Includes ability to perform open neutral, open ground, and line polarity forward/reverse test conditions. Adaptable - Universal rear panel receptacle allows for testing products with any plug configuration. Accurate - True RMS meter accurately measures both sinusoidal and non-sinusoidal waveshapes. This is important when testing products using a switch mode power supply which can generate non-sinusoidal leakage currents. Calibrated, traceable to NIST. Flexible - A front panel switch permits testing either through the power cord of the product under test, from surface/ patient connection-to-ground, or from surface/ patient connection-to-surface/ patient connection. Portable - Lightweight, with integral handle. Other Features - Product Ground Switching (grounding conductor maintained to device under test when not measuring leakage). Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation). Proven - These are the only leakage current testers designed and supported by Product Safety experts. That is part of the reason why they have become the standard in the industry. Full technical support by experienced safety engineers.
-
product
Qualification Tester
LQ402
Computer Gesteuerte Systeme GmbH
The qualification tester LQ402 is designed to support up to 6 DUTs (Device under Test), for which the loads are installed in separate load boxes. The system consists out of 2 cabinets. One is for the electronic components with the primary measurement devices and the other one holds the 6 load boxes.
-
product
Automatic Calibration Module
ACM4509
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.





























