Calibration References
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services
-
Product
Portable Calibration Shaker Table
AT-2030
-
The AT-2030 portable calibration shaker table is designed for simple accelerometer and vibration transducer calibration without the need for advanced features. AT-2030 shaker table and vibration calibrator is a variable frequency, variable amplitude, battery operated portable shaker capable of calibrating accelerometers, transducers, and proximity probes. Applications are producing a known vibration signal in g’s, mils, or ips for sensor, wiring, instrumentation, and system checkout in vibration condition monitoring applications.
-
Product
IR Calibration Instruments
-
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
Product
Horizontal Calibration Instruments (Lab)
THV
-
The horizontal THV instrument has been designed for calibration and certification of gauging equipment of small dimension. It allows easy and precise checking of plug gauges, ring gauges, thread plug gauges, test and dial indicators as well as measuring of high precision production parts.
-
Product
Electrical Calibration
GF6018A
-
Beijing GFUVE Electronics Co.,Ltd.
The equipment is compliance with national verification regulation: JJG1242005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.
-
Product
FOCL Reference Signal Modem
VCH-607
-
FOCL reference signal modem VCH-607 is designed to receive and transmit electrical signals with a nominal frequency of 100 MHz through a fiber-optic system and generate electrical signals with a nominal frequency of 5 and 10 MHz, coherent with the input signal. Reception and transmission through the FOCL is provided using a pair of modems: one is configured as a Transmitter and is installed at the end of the FOCL where the signal source is located, the second is configured as a Receiver and is installed at the opposite end of the FOCL.
-
Product
Thermocouple Calibration Furnace
9118A
-
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
-
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Acoustic Emission Calibrator
-
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
Product
25µA Micropower Voltage References
ISL21070
-
The ISL21070 voltage references are analog voltage references featuring low supply voltage operation at ultra-low 25µA max operating current. Additionally, the ISL21070 family features guaranteed initial accuracy as low as ±0.2% and 30ppm/°C temperature coefficient. These references are ideal for general purpose applications for performance at lower cost.
-
Product
Calibration Units
-
Optical Stroboscope and Tachometer European Calibrator Unit was originally designed for in-house test and calibration of our comprehensive range of Digital Optical Tachometers, Optical Speed sensing products and Stroboscopes.
-
Product
Machine Calibration and Optimisation
-
Renishaw's laser interferometer and ballbar measurement systems assess, monitor and improve the static and dynamic performance of machine tools, co-ordinate measuring machines (CMMs) and other position-critical motion systems.
-
Product
Partial Discharge Calibrator
TPK-H
-
The high voltage-resistant Partial Discharge calibrator is used to determine the correction factor in the PD test circui.
-
Product
Calibration Hand Pumps
-
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
Product
High Accuracy AC Reference Source
515
-
Clarke-Hess Communications Research
The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.
-
Product
Reference Solutions
-
As you seek solutions to evolving test challenges, Keysight Reference Solutions provide the right combination of hardware, software, and measurement expertise through programming examples highly optimized for specific applications. Reference Solutions show you how to get the most out of your test equipment, helping you achieve half the time to insight.
-
Product
Calibration Software
-
AMETEK Sensors, Test & Calibration
Our calibration software provides an easy way to calibrate gauges, RTD´s, thermocouples, transmitters, thermoswithes, and pressure switches. Complete a full calibration from entering the details of the gauge to printing out a calibration certificate. Reduce operating time by automating calibration procedures, reduce sources of error by automatically reading and storing values from the reference, and customize certificate templates to fit your needs.
-
Product
Calibration Services
-
Your CLIO hardware can be furnished with (or be submitted for) a SIT Certificate of Calibration. This document, produced by a laboratory accredited by the Italian Calibration Service, reports measurement data of the primary quantities generated and analyzed by the instrument (AC Voltages) traceable to National and International Standards. This document is usually requested for ISO compliance.
-
Product
AC Reference Generators
SRB
-
Computer Conversions Corporation
The SRB Series are miniature, Bulk-head Mount, low cost AC reference generators to supply moderate power 2-115VAC excitation to Synchro's, Resolvers, LVDT's and related converters in COTS-Military and industrial applications for measurement, control, simulation and data communications.
-
Product
Reference Detect Switch
RDS Series 1.5” x 1.5” x 0.6”
-
*Connectorized Package *Internal/External Reference Detect Switch *Standard Internal TCXO (±2.5 ppm) *Optional Internal OCXO (±90 ppb)
-
Product
Calibration Light Sources
-
For wavelength calibration, Avantes offers a variety of sources including Argon, Mercury-Argon, Neon, Zinc, and Cadmium. All Avantes spectrometers are factory wavelength calibrated and do not require recalibration as they have fixed slits and optics. For those customers who wish to do their own calibrations, the AvaLight-CAL light sources can be used for recalibration purposes. For auto-calibration, AvaSoft-Fill provides a calibration procedure to make this easy.
-
Product
Reference Thermometers
-
Reference thermometers (standard thermometers) are, due to their excellent stability and their geometrical adaptations, ideally suited for applications in industrial laboratories. They enable easy comparative calibration in baths, in tube furnaces and in dry-well calibrators. The advantage of reference thermometers is the wide temperature range, and with this, their flexible operation. Furthermore, with their low drift, a long service life is ensured.
-
Product
Mass Calibration
-
Trescal provides full Mass Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Mass Calibration services can be delivered at your site or at our lab. Accreditations for our mass calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Calibrated Diffuse Reflectance Standards
-
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
Product
Insulation Tester Calibrator
DecR
-
SCOPE offers High Resistance, High Voltage Decade Resistance Box - DecR. It contains number of smartly configured precision resistors. They are arranged in such a way that user can obtain desired resistance value by selecting appropriate decade switches. DecR is designed using the high quality specially selected resistors. These range of high ohm resistance decades are ideal for variety of applications, having a voltage rating up to 5 kV. It covers the resistance range from 1 kilo ohm to 1 tera ohm. DecR can also be customized as per requirement. DecR is housed in a rugged case and available in 3 / 4 / 6 / 9 decades or in binding post configuration
-
Product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
-
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
EMC Calibration
-
Trescal provides full EMC Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. EMC Calibration services can be delivered at your site or at our lab. Accreditations for our emc calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Calibration & Demag.
Model 990A/990C
-
The Model 990 Series Magnetreaters® are highly accurate, pulse type, ringing demagnetizers (also called treaters) for the controlled stabilization of permanent magnets and permanent magnet assemblies. Regardless of line voltage stability, they provide a controlled output through continuous pulse amplitude regulation. Treating voltage is variable from 0 to 600 VDC. Additional energy can be added to the Model 990 Series by interconnecting a Model 992 Energy Booster. The energy level is increased from 18 to 36 watt-seconds. With this option, treating coils will produce higher demagnetizing fields and lower ringing frequencies, which can provide greater field penetration in some applications.
-
Product
Instrument Transformer Calibrators
MRL 11
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
Product
6GHz SMA Calibration Kits
CAL-SMA-6B
-
The CAL-SMA-6B Basic calibration kit provides the elements for performing Open–Short–Load and Through calibrations for one and two port VNA measurements.