Calibration References
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services
-
Product
V/mA Process Calibrator
Model KM-CAL-907
-
Kusam Electrical Industries Limited
This is a source and measure type of calibrator and it gives high accuracy of 0.02% . It has dual display. 5 digits display for measure and 6 digits display for source & white LED for backlight.
-
Product
IR Calibration Instruments
-
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Calibration and Repair
-
Traceable vibrometer calibration insures a high level of data quality, critically important for many applications in industry, science and medicine. Polytec service engineers ensure fast and efficient equipment calibration that is traceable to national and international standards, intended to be ISO/IEC 17025 compliant.
-
Product
Energy Meter Calibration
GF312D1
-
Beijing GFUVE Electronics Co.,Ltd.
The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.
-
Product
23KHZ Reference Measurement Microphone
M23R
-
The M23R is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
Calibration Kits
-
Atec’s Portable Calibration Kit, PN AHT63506-1, is used to calibrate instrumentation and transducers in engine test cells, as required per T.O. 33K6-4-3416-1 or Atec Technical Manuals.
-
Product
mA Loop Calibrators
-
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
Product
Rugged GPS Time & Frequency Reference
VersaSync
-
VersaSync is a high-performance GPS master clock and network time server that delivers accurate, software-configurable time and frequency signals in harsh environments, including GPS-denied areas. Now with M-Code!
-
Product
Reference DAC, Pre And Headphone Amplifier
CALLIA
-
Designed and manufactured in the United Kingdom, CALLIA embodies the Prism Sound uncompromising approach to audio resulting in the most accurate and detailed DAC available.
-
Product
Calibrate Camera RAW Image Files
SpyderCUBE™
-
Accelerate RAW processing by taking one reference shot under any light condition to set the white balance, exposure, black level and brightness right from the start for your entire series of photos.
-
Product
Network Analyzer N-Port Calibrated Measurements
S93551B
-
The S93551B adds a multiport analyzer mode that enables full N-port error correction and measurement capabilities using an external test set.
-
Product
Automatic Calibration Module
ACM2509
-
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
-
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Thermocouple Calibrator
CA10
-
Dual function CA10 Thermocouple Calibrator can be used to source Type K thermocouple output values or measure Type K thermocouples. Quickly select output value using the rotary switch with coarse and fine adjustments.
-
Product
NI Real-Time Test Cell Reference System
780590-35
-
VeriStand Full Development License with NI Standard Service , Include 1 Year SSP
-
Product
Argon Calibration Source
AR-1
-
The AR-1 produces low-pressure argon emission lines from 696-1704 nm for use in performing fast, reliable spectrometer wavelength calibrations.
-
Product
Reference Coordinate Measuring Machine
XENOS
-
XENOS from ZEISS features two linear drives in the Y direction, which are synchronized via a new technology developed by ZEISS: the central drive. It ensures optimal force distribution of the drives depending on the position of the X axis.
-
Product
Calibrators/ Digital Manometers
-
Meriam has earned the reputation as a world leader in the accuracy of our calibrators and digital manometers. We offer excellent hand held performance at a value price. Features include min/max capture, data record, pressure measurement, averaging and timed pressure tests. "Smart" digital manometers are well suited for field measurement and process control.
-
Product
SMARC 2.1 Reference Carrier Board with M.2 Extension
I-Pi SMARC Plus
-
The I-Pi SMARC Plus is small (110mm x 110mm) SMARC reference carrier board based on SGeT SMARC (Smart Mobility ARChitecture) 2.1 hardware specification. Together with the SMARC short size module of your choice and off the shelf add-on cards, you can quickly emulate the functionality of your desired end product for software development and hardware verification.
-
Product
Bond Force Measurement And Calibration Systems
BFS-20
-
Based on its design and easy handling it can be used also on other brands to measure the bond force.
-
Product
Calibration and Verification Kits
-
Flann offers a wide range of calibration and verification kits to suit many applications and price points. Compatibility with the vast majority of current and legacy VNAs can be provided. Additionally full customisation of our kits is possible to suit your requirements.
-
Product
Sound Level Calibrator
521
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Calibration Equipment
-
Devices and instruments used to ensure the accuracy and reliability of other measurement devices.
-
Product
Electrical Calibration
-
Process Instruments calibrates a wide variety of test and measurement equipment. All calibration procedures are written, and most are automated, insuring reliability and repeatability of measurements.
-
Product
Reference Transmitter
81492A
-
Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.
-
Product
Calibration Equipment
-
Calibration is the method of comparing tools and measuring devices to higher accuracy standards. Torque calibration equipment is the official means by which torque testers and sensors are calibrated and are traceable to National or International Standards, such as N.I.S.T and ISO. In order to maintain precision accuracy, it is essential that torque measuring equipment be calibrated regularly. By equipping your team with Mountz calibration equipment, you can avoid the costly chore of sending your torque tools to the lab whenever they fall out of alignment.
-
Product
Service, Modernization, and Calibration Serivices
-
In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
HiPot Calibrator
Model 9102
-
The 9102 Hipot Calibrators is specially designed standard devices for instrument calibration lab. The 9102 can simulate multiple loads and apply to various Hipot testers. These calibration equipment can save manufacturers a great deal of regular calibration fee.