Temperature Calibration Baths
-
Product
Calibration Baths
-
Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. A world-class temperature controller and 30+ years of experience make these the choice of National Metrology Institutes and calibration laboratories worldwide. Fluke Calibration temperature baths include: compact temperature baths; deep-well temperature baths; standard calibration baths; resistor maintenance baths; ice-point baths; bath / temperature controllers.
-
Product
Immersion Temperature Probe
U1181A
Temperature Probe
Measure the temperature of food, oil, and other liquids within the range of -50°C to 700°C.
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
LoRaWAN® Enabled Temperature And Humidity Sensor
EVA-2310
Temperature Sensor
LoRaWAN® wireless connectivity-20 °C to 55 °C temperature detection range0%RH to 90%RH humidity detection rangeBattery life up till 5 years@25 °C, 15 mins interval settingEasy to deploy and maintain
-
Product
FD-11614, 16-Channel Temperature Input Device for FieldDAQ
785854-01
Temperature Input Module
The FD-11614 measures up to 16 thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11614 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11614 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11614 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
USB-TC01, 1-Channel Temperature Input Device
781314-01
Temperature Input Module
The USB‑TC01 is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take … temperature measurements with your PC. You can connect the USB‑TC01 to any USB port to use your PC as a display and monitor data in real time. The USB‑TC01 is compatible with J, K, R, S, T, N, E, and B thermocouples.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
785259-01
Temperature Input Module
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
Linear/Angular Measurement Kit
55281B
Mechanical Calibration Kit
The Keysight 55281B Linear/Angular Measurement Kit is part of the Keysight 5530 Laser Calibration System and enables the system to measure both linear velocity along a machine's travel path as well as rotation about an axis perpendicular to the axis of motion (pitch and yaw).
-
Product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
Temperature Input Module
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
Temperature Input Module
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
Electronic Calibration Module
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
Electronic Calibration Module
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
LoRaWAN® Enabled Temperature PT1000 Round Head Probe Sensor
EVA-2311
Temperature Sensor
LoRaWAN® wireless connectivity-70°C to 200°C temperature detection rangeIP67 for PT1000 Round Head Probe SensorBattery life up till 5 years@25°C, 15mins interval settingEasy to deploy and maintain
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
Mechanical Calibration Kit
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz, Type-N(m), 50 Ohm
85514A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
Product
Air Temperature Probe
U1183A
Air Temperature Probe
Measure dryer, transport pipe, and surrounding air temperature within the range of -50°C to 800°C.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
Mechanical Calibration Kit
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745690-T002
Temperature Sensor
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
Calibration Cable
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Temperature Module
U1586B
Temperature Input Module
The U1586B temperature adapter expands the capabilites of your handheld oscilloscope or handheld digital multimeter to measure temperature, either in °C of °F. To be used with a K-type bead thermocouple, and with approximately 1600 hours battery life with an alkaline battery, this adapter ensures you get the most out of your handheld scope or DMM purchase.
-
Product
FD-11613, 8-Channel Temperature Input Device for FieldDAQ
785640-01
Temperature Input Module
8-Channel Temperature Input Device for FieldDAQ - The FD-11613 measures up to eight thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11613 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11613 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11613 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
Electronic Calibration Module
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.





























