Temperature Calibration Baths
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
Electronic Calibration Module (ECal), 26.5 GHz, 3.5 Mm, 2-port
N4691D
Electronic Calibration Module
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Liquid Baths & Multi-Liquid Baths
-
Liquid baths temperature condition fluid for immersing products and immediately exposing them to a specific temperature.Multi-liquid baths provide many constant temperature environments in a single unit. The temperature in each bath may be controlled at different temperatures.
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745685-T02
Temperature Sensor
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
Temperature Input Module
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Temperature Calibrators
-
Fluke Temperature Calibrators simulate process sensors for testing temperature instrumentation. Specifically designed for the field, these lightweight compact tools are EMI tolerant, dust and splash resistant and offer an easy to use single push button interface. When paired with a temperature sensor they can take high accuracy temperature measurements to verify process temperatures and ensure the highest product quality and safety. There are a variety of different temperature calibrators designed for your unique calibration and testing requirements.
-
Product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
Temperature Input Module
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
Mechanical Calibration Kit
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
Product
Air Baths/Oil Baths
-
Measurements International Ltd.
Peltier Cooled, DC Stirrer Motors for Low Electrical Noise, Dual Drain Ports, Adjustable Stir Speed, Free Standing Bench Height, Grounded Stainless Steel Tank.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
Mechanical Calibration Kit
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
Temperature Calibrators
-
Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.
-
Product
Temperature Calibration Software v5.1
MET/TEMP II
-
MET/TEMP II software allows you to easily automate the calibration of a wide range of temperature sensors. It provides a comprehensive temperature calibration solution that allows you to test large quantities of sensors, calculate characterization coefficients, and print calibration reports. You can standardize comparison or fixed point calibrations and use multiple temperature sources or references in one test.
-
Product
Thermocouple (J-Type) And Temperature Probe Adapter
U1185A
Temperature Probe Adapter
The U1185A consists of a thermocouple bead (J-type) and a mini connector to dual banana plugs.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Thermocouple (K-Type) And Temperature Probe Adapter
U1186A
Temperature Probe Adapter
Consists of a K-type thermocouple bead and a mini connector to dual banana plugs.
-
Product
Temperature Calibrators
-
This temperature calibrators offering is a complete selection of everything needed to calibrate your temperature measurement equipment all in one place.
-
Product
Temperature Calibrators
-
We offer temperature calibrators in different shapes. We offer temperature dry blocks that can generate an accurate temperature, for example for temperature sensor calibration. We also offer electrical temperature calibrators that can measure and simulate various temperature sensors (RTDs and thermocouples). We also offer high-accuracy reference temperature probes.
-
Product
Liquid Thermal Shock Baths
TSB Series
-
CSZ's Liquid thermal shock chambers consist of separately controlled hot and cold baths. Product is submersed in fluid and thermally stressed between the hot and cold baths, resulting in immediate product temperature changes. CSZ uses perfluorinated fluid that does not coat the product or conduct electricity for use in both the hot and cold baths to eliminate cross contamination and reduce evaporation losses.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (f)
85563A
Mechanical Calibration Kit
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
-
Product
Standard Resistor Oil Bath
9400
-
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
Product
Water Baths
-
A container of water heated to a given temperature, used for heating substances placed in smaller containers.
-
Product
Electroplating Bath Analyzer
-
optek’s electroplating analyzers are inline devices designed to measure plating solution’s metal concentration in real time. These analyzers can be designed to accommodate virtually any concentration range. Operationally, the analyzer passes a white light beam through the plating solution to be monitored. Then, light absorbance is measured at two distinct wavelengths, and the difference in light absorbance between the two wavelengths is equated to a plating solution concentration.
-
Product
Electronic Calibration Module, DC To 9 GHz, 2-Port
N7552A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors