Reference Transformers
See Also: References, Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
Wall Transformer, Converters & Chargers
-
PeakTech Prüf- und Messtechnik GmbH
An appliance for holding or inserting a charge of power.
-
Product
Reference Radiators / Comb Generators
-
The Spectrum Generator is a family member of the Schwarzbeck pulse generators, which are used as pulsestandard world wide. Whilst the latter one uses a bounce free relay contact to discharge a coaxial lineto the load resistor, it uses a special avalanche transistor instead of the relay contact.
-
Product
Transformer Turns Ratio Testers
-
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
Product
AC Reference Generators
SR23
-
Computer Conversions Corporation
The SR23 Series are miniature, low cost AC reference generators designed to supply 26 or 115 volt excitation (2-115VAC) to synchros or resolvers in military and industrial control applications. They accept +/-15V DC or +/-12V DC power inputs and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6”x3.1”x1”H.
-
Product
Transformer Monitoring
-
MTE offers a broad range of products and solutions for the online gas-in-oil monitoring of transformers (online DGA). With its individual and modular system components MTE provides the optimal customer oriented solution for utilities, industries and transformer manufacturers.
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
Instrument Transformer Test Systems
-
Our systems for testing voltage (VT) and current (CT) instrument transformers are conceived among other things for testing accuracy and insulation.
-
Product
2 Channels, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTB
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Current Transformer Testers
-
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
Product
Transformers (Murata Power Solutions Products)
-
Murata transformers are ideally suited to high-frequency designs. The products come in a variety of industry-standard packages and can be used in applications where impedance matching, voltage conversion, isolation and current sensing may be required.
-
Product
Partial Discharge Detection and Localization System for Power Transformers
AE-150™
-
The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.
-
Product
DGA Monitor for Transformers
OPT100 Optimus™
-
The Vaisala Optimus OPT100 DGA (Dissolved Gas Analysis) Monitor for Transformers gives you out of the box performance, completely eliminates false alarms, and offers the best long-term stable measurements of any device on the market – all with no maintenance. Spectral scanning provides selective gas measurement.
-
Product
SMARC 2.1 Reference Carrier Board with M.2 Extension
I-Pi SMARC Plus
Carrier Board
The I-Pi SMARC Plus is small (110mm x 110mm) SMARC reference carrier board based on SGeT SMARC (Smart Mobility ARChitecture) 2.1 hardware specification. Together with the SMARC short size module of your choice and off the shelf add-on cards, you can quickly emulate the functionality of your desired end product for software development and hardware verification.
-
Product
VARIABLE TRANSFORMER DC POWER
208163V
-
Motorized Variable Transformer Controlled Power Supply, P/N 208163VInput power: 208 VAC, 6 Amps, 3 PH, 60 HzOutput: 0 to 120 VDC, 16 Amps max.Ripple: 5%Manual control with variable transformerCircuit breaker / ON OFF on the 208 VAC, 3 PH input lineProtection fuse provided on the outputPOWER ON lightIndoor enclosure: 24H x 20W x 9DVoltmeter and ammeter are installed to monitor the output.All input/output connections are available inside the enclosureSystem includes main unit and remote assembly.
-
Product
Rugged GPS Time & Frequency Reference
VersaSync
-
VersaSync is a high-performance GPS master clock and network time server that delivers accurate, software-configurable time and frequency signals in harsh environments, including GPS-denied areas. Now with M-Code!
-
Product
Transformer Winding Resistance Meters
TWA Standard Series
-
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
Product
PXIe-6614, 5 V, 8-Channel, Precision Reference PXI Counter/Timer Module
782353-01
Counter/Timer Module
PXIe, 5 V, 8-Channel, Precision Reference PXI Counter/Timer Module—The PXIe‑6614 is a high-precision counter/timer module that performs encoder position measurement, event counting, period measurement, pulse-width measurement, pulse generation, pulse-train generation, and frequency measurement. It features eight counter/timers, digital debouncing filters, and TTL/CMOS‑compatible digital I/O. The PXIe‑6614 offers industrially rugged features for a wide array of applications such as automotive/aerospace, industrial/motion control, and manufacturing test. Measurements are highly accurate and precise over longer periods of time because of the oven‑controlled crystal oscillator (OCXO) in the module.
-
Product
Split Core Current Transformers
-
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
Product
Transformer Insulating Oil Dielectric Tester
CXYJ-501
-
Shenzhen Chuangxin Instruments Co., Ltd.
Insulating Oil Tester is designed according to of GB-86 and IEC60156 standards.
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Heading Reference Directional Gyroscopes
4000HR-series
-
The 4000HR air-driven directional gyro offers some of the best features of our other popular models. It inherited all of the functionality and reliability of the industry standard 4000B upon which it’s based, and it picked up a heading reference bug from the 4000C autopilot model.
-
Product
BMS Transformers
-
In large battery pack applications with daisy chain connections, the number of cells connected in series is very high, and the large voltage differences demand component-to-component isolation. The serial communication links between boards need to be isolated by transformer coupling circuits instead of capacitor coupling.
-
Product
Clamp-On / Precision / Split Core Current Transformer
-
Transformer Ratio (Arms) : 100A / 1AColours : Red, yellow, blueConnection : Safety Sockets for Banana Plugs ф 4mm Jaw Opening : Cable Dia 15mm max.
-
Product
Transformer Ratio Meters
-
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
Product
Bloomy Simulation Reference System
System
The Bloomy Simulation Reference System provides a hardware in-the-loop (HIL) test environment for dynamic, closed-loop testing of many aerospace and transportation control systems. The reference system integrates the computing, I/O, and software components needed for standalone use or to form the basis of a more complex test system.
-
Product
Current Transformer
-
Nippen Electrical Instruments Co.
DIGITAL METERS NIPPEN electronic energy meters are panel mounting type innovative energy monitoring devices ,having state of the art electronic microcontroller circuitry for reliability and accuracy. They can be used for 1Ø / 3Ø balanced and unbalanced loads.
-
Product
Micropower Voltage Reference
ISL21010
-
The ISL21010 is a precision, low dropout micropower bandgap voltage reference in a space-saving SOT-23 package. It operates from a single 2.2V to 5.5V supply (minimum voltage is dependent on voltage option) and provides a ±0.2% accurate reference. The ISL21010 provides up to 25mA output current sourcing with low 150mV dropout voltage.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.





























