2-wire
resistance measurement method.
-
Product
PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays
M9120A
Matrix Switch Module
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
Product
2-Wire Bus Buffers
-
Renesas' 2-wire bus buffers are designed to improve data transmission speed on SMBus or similar 2-wire serial bus interfaces.
-
Product
PXI-2529, 128-Crosspoint, 2-Wire PXI Matrix Switch Module
778739-01
Matrix Switch Module
The PXI‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXI‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXI Switch - 4x8 2-Wire Matrix Module
PXI-7931
Matrix Switch Module
ADLINK PXI-7931 is a matrix module with 32 cross-point 2-wire relays (DPDT, 2 Form C). The default configuration of the PXI-7931 itself is a 4-group 2x4 2-wire matrix. With the termination board, TB-6231, users could flexibly choose one of the configurations: one 4x8, two 4x4, one 2x16, two 2x8 and four 2x4. Any contact of the PXI-7931 can connect to other contacts, individually or in combination. The PXI-7931 matrix module simplifies the wiring and makes it easy to change the internal connection path. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7931, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
Product
PXIe-2529, 128-Crosspoint, 4x32 OR 8x16, 2-Wire PXI Matrix Switch Module
780587-29
Matrix Switch Module
128-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or an 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXIe‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
Matrix Switch Module
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix Topology Without Column Protection Resistors
782385-11
Terminal Block
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Banana-Triax Adapter For 2‑Wire (Non-Kelvin) Connection
N1297A
Accessory Kit
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
Product
TB-2635, Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block
778839-01
Terminal Block
Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block - The TB-2635 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 8×16 matrix. You can directly connect the TB-2635 to the front panel I/O connectors of the PXI-2529. The TB-2635 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
Toxic Gas Sensor
Model 100
-
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
Product
Temperature Sensors
TT420-LT
-
Features• 2-wire, loop-powered 4-20 mA analog output• Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner• Integral 1/2" flexible liquid-tight conduit fittings• TT420Z-LT 1/4” stainless steel probe with 1/8 NPT adapter• TT420S-LT 3/8-16 threaded stud probe • FM approved, Dust Ignition-proof• Class II and III, Div I (E, F, G); NEMA 4
-
Product
Industrial Grade PCI DIO 96 Board
MS 1817
-
*96 digital input/output lines*Support s all PPI Modes (Mode0, Mode 1 and Mode 2)*5 V TTL/CMOS*Compatible with NI DIO Card*2-wire handshaking capability*Known power-up
-
Product
In-Line IR Sensor
ILA
-
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Product
Temperature Sensors
TT420
-
Features• 2-wire, loop-powered 4-20mA analog output• Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner• Compatible with PLCs, meters, and data acquisition systems• No user calibration• TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap• TT420F mounts onto any flat surface• UL listed, Intrinsically Safe (IS)• Class I, (C, D) and Class II, (E, F, G)
-
Product
Keysight Dual 4x16 Armature Matrix for 34980A
34932A
Matrix Switch Module
The Keysight 34932A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x16, 8x16, or 4x32 configurations 128 2-wire cross-points 300 V, 1 A switch; 2 A carry current Connections to the internal DMM Latching armature relays, with relay counter Expandable via four 2-wire analog buses
-
Product
Interface
RAR-PCIE
Interface
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.
-
Product
PXI High Density Multiplexer: 99-ch, 2-Wire, 100Vrms/1A, Armature Relays
M9103A
Multiplexer Module
The M9103A, a high-density, high-power 99-channel multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time, or multiple channels can simultaneously connect if needed. This module is ideal for routing multiple analog signals to a measurement device in an automated test environment (ATE) or data acquisition systems. Each channel switch has a high and low for 2-wire switching. The high-quality armature relays are capable of switching up to 100Vrms, with up to 60W of power. Choose from the durable connector block or standard cable connections.
-
Product
Ultra High Density Matrix Switch Card
1260-45
Switch Card
The Astronics 1260-45 offers the highest-density switching matrices in a single-slot C-size VXI module, configurable as 11 different matrices from four 4x16 2-Wire to one 16x16 two-wire. Easily extend this module externally to build a larger matrix in a single VXI chassis to satisfy even the most dense applications.
-
Product
RS-485 and RS-422 Transceivers
-
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Product
Switch Mainframe
SW1002
-
Switch between voltmeter and battery tester while testing. 264 channels max. (2-wire) to 72 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.
-
Product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix topology With Column Protection Resistors
782385-10
Terminal Block
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Digital Power Recorder
MPR-601W-01
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
Product
Speed Sensor Intrinsically Safe
ST420
-
Features• 2-wire, loop-powered 4-20 mA analog output• No user calibration – works right out of the box• Standard and custom measurement ranges available• Reverse-wiring protected• Works with Electro-Sensors magnetic pulser discs / wrapsRugged stainless steel M18x1 housing; UL listed, Intrinsically Safe (IS); Class I, Div I (C, D) Class II, Div I (E, F, G)
-
Product
Earth Ground Tester
-
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
Product
4 Wire Earth Resistance Testers
4234 ER
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth testing at 2Ω, 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test.● 3-Wire test.● 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● Robust, compact and easy-to-carry.
-
Product
PXIe-2738 , 256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module
782835-38
Matrix Switch Module
256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
Modbus Register Converter
Model 2390
-
* Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.
-
Product
Keysight Dual/Quad 4x8 Reed Matrix for 34980A
34933A
Matrix Switch Module
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current