Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Three-Phase Electric Power/Energy Calibrator
MC133Ci
The MC133Ci model is a compact one-housing three phase electric power/energy calibrator. It can supply the device under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
product
Calibrator Module
CAP CAL
The purpose of CAP-CAL is to check the correctness of Tan Delta and Capacitance of TD 5000 and TDX 5000. The calibrator includes an extremely high accuracy high voltage capacitor, which comes with a certificate issued by ISA - Altanova Group lab.
-
product
Torque and Force Calibrators
Self-contained, semi-automated, multi-functional calibrator, which provides a rapid highly accurate and safe means for calibrating and testing a wide variety of torque and force measuring instruments.
-
product
Automatic Battery with Filters with Standard Contactors
BATLVF120
Lifasa - International Capacitors, SA
Accessories: Differential protection
-
product
Electrical Calibrators
We offer different electrical calibrators for electrical quantities. We mainly offer products for DC signals related to process calibration, such as current, voltage, resistance and frequency.
-
product
Altitude Encoder Calibration Programmer
ECP-100
The ECP-100 allows the avionics technician to assign serial port protocols, 100' or 10' resolution and/or allow programming of the calibration curve on Trans-Cal Altitude Encoders using the RS232 port.
-
product
OTDR Training & Calibration Solution
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
product
Humidity calibration with humidity calibrator
HUMOR 20
The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements and is traceable to international standards. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors and also for monitoring instruments with cubic dimensions.
-
product
Standards Waveform Generator
3110A
The 3110A software is built around the simple concept of a waveform segment. Each waveform segment can have a unique waveform, (sine, square, triangle, and/or DC offset). Frequency, amplitude and DC offset can be clipped, fixed, variable or swept. Segments can be calibrated (as required in CS101) and set to continue on to the next segment or to hold for an external trigger.
-
product
Ice Point Calibrators
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
product
Standard Type Externally Modulated Optical Transmitter
HT8500H
Hangzhou Huatai Optic Tech. Co., Ltd.
1550nm externally modulated optical transmitter is the core equipment in the RFTV network system.RFTV is a unidirectional analogue and digital video broadcast. It adopts high efficiency modulation mode for RF carrier wave and its economy , flexibility and bandwidth validity is beyond comparison of IPTV. By adopting EPON, GEPON or P2P access mode to realize triple-play and FTTx, RFTV broadcasting network in 1550nm optical wavelength still plays an important role.
-
product
Standard Accessory Replacement Kit for PP017/PP018
PKIT4-5MM-101
Standard Accessory Replacement Kit for PP017/PP018.
-
product
Standard Mass Flow Meter
Series II
Offers outstanding value in a wide range of industrial and lab applications. Exceptional accuracy and repeatability with flow ranges from 0.014 cc/min up to 1670 l/min. and working pressures up to 6000 PSIA. Offers multi-gas and multi-range capability
-
product
Bond Force Measurement And Calibration Systems
BFS-20
Based on its design and easy handling it can be used also on other brands to measure the bond force.
-
product
Calibration Short For Digital Multimeters
34172B
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
product
SPL Calibrator -124 dBSPL @ 1 kHz
511ES124
The 511ES124 is designed to provide 124 dBSPL at 1 kHz to meet the needs of the low sensitivity microphones found in many high SPL measurement applications. The microphones used in Car Stereo competitions like dB Drag racing, IASCA, and USAC have had their sensitivities reduced to the point where 94 dBSPL may no longer be adequate for calibration.
-
product
Instrumentation Calibration Services
We offer a range of instrumentation calibration services for Kemo products in addition to other signal conditioning and sensors. We have many decades of experience in the manufacture, test and calibration of our instruments and those of our competitors. Please refer to the list below for an example of our calibration options, all equipment used within our calibration department is calibrated and traceable to a UKAS accredited National standard:
-
product
Class 2 Sound Level Calibrator
SPC70
The SPC70 is a Class 2 sound level calibrator suitable for periodic testing of sound level meters and verifying their accuracy before and after readings, in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB. The output is accurate to 0.5dB with low levels of harmonic distortion. The SPC70 is compatible with the Martindale SP79 Class 2 Sound Level Meter and other meters with microphones up to 25mm.
-
product
Ultra Precision Touch Screen Calibrator
DVC-9500
Unprecedented Accuracy of +/-0.0005% error or +/-5ppm- Less than 3ppm/DegC temperature drift- Output simulation of 13 types of thermocouples- +/-2V and +/-20V programmable bipolar ranges- Full Color Touch Screen interface for intuitive interaction
-
product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
product
Standard Products
SBIR offers an extensive line of reliable, high performance test equipment used to characterize and calibrate IR, Visible and Laser systems. Products include blackbodies, visible sources, target wheels, targets, collimators, target projectors, laser test modules/systems and IRWindows™ software for automated testing. These modular, cost effective instruments are user-friendly and easily integrated into automated test systems. For more information, including printable data sheets, select a product from the list.
-
product
UL Standards Testing and Certification
If you are selling your product in the United States, your product must comply with the applicable nationally accepted UL standards. F2 Labs can evaluate and test your product, help you through the UL certification process and enable you to certify your product to the UL requirements through a Nationally Recognized Test Lab (NRTL).
-
product
Test gas - for calibration
Test gases for gas measuring and gas warning devices.Enables the functional control and calibration of measurement technology.
-
product
Standard Weather Radar Test Panel
TA-3
Universal weather radar test panel with integral gyro simulator and monitor jacks. Discrete test jacks for common signals, altitude select switches and a dedicated connector for the RDS series radars. Click on picture for larger view.
-
product
DC Power Source for Standard Lamp
DC502
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
product
The Industry Standard for Automated Network Protocol Validation
IxANVL
Keysight Network Applications and Security
With Ixia’s IxANVL (automated network validation library), you can quickly and effortlessly access a vast array of protocol libraries and utilities to validate protocol compliance and interoperability. Easy to use thanks to an enhanced GUI and flexible test-automation capabilities, IxANVL delivers a number of key advantages. By emulating large, multinode networks, it not only reduces costs—it also leads to more efficient testing and faster product-release times. And extensive and thorough automated testing increases your confidence in product quality.
-
product
Standard Voltage 50 Pin D-Type Connectors
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.