Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Automated Calibration
ORION
-
ORION automates the process of characterization and calibration of engines. It facilitates the calibration process by taking control of both the ECU calibration system and the test cell control system to run experiments as part of an automated calibration process. With connectivity to IAV’s EasyDOE, Mathworks’ MBC Toolbox and other DOE tools, ORION provides an extremely powerful environment for mapping an engine and generating the Engine Management System calibration tables. The modular design means the product can be configured to a users’ specific requirements and work practices, rather than having to adhere to rigid methodologies dictated by prescriptive software.
-
Product
Infrared Calibration
-
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.
-
Product
Automated Pressure Calibration System
4322
-
The Fluke Calibration 4322 Automated Pressure Calibration System enables almost any user to calibrate almost any pressure gauge, transducer, transmitter or switch, including vacuum, compound, absolute and high-pressure devices. It provides high-end, laboratory-grade performance across a very wide range, on the bench or in situ.
-
Product
Sound Level Calibrator
521
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
NanoLattice Pitch Standard (NLSM)
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
Product
Calibrators
-
Thermocouple temperature calibrator is capable of measuring and simulating up to 8 types of thermocouples (J, K, T, E, R, S, B, N), as well as a voltage in mV.
-
Product
Portable Calibration Shaker Table
AT-2030
-
The AT-2030 portable calibration shaker table is designed for simple accelerometer and vibration transducer calibration without the need for advanced features. AT-2030 shaker table and vibration calibrator is a variable frequency, variable amplitude, battery operated portable shaker capable of calibrating accelerometers, transducers, and proximity probes. Applications are producing a known vibration signal in g’s, mils, or ips for sensor, wiring, instrumentation, and system checkout in vibration condition monitoring applications.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
Multifunction Calibrators
-
Calmet Smart Calibration Devices
Calmet offers a variety of Multifunction Calibrators including the C101, the Calpro 101, and the ZW Series.
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
Calibration Services
-
Hirst Magnetic Instruments Ltd
Calibration is essential to keeping our sensitive measuring equipment accurate. We calibrate equipment traceable to National Physical Laboratory (NPL) standards.
-
Product
Calibration And Measurement
-
Ectron has a long tradition dating back to 1964 in being the industry leader in supplying super high precision, highly reliable and accurate Metrology, Simulators/Calibrators products.
-
Product
Cryostat Calibrators
-
Electronic Development Labs, Inc.
Specialized, low-temperature, passively cooled, or liquid nitrogen-based apparatuses designed to calibrate temperature sensors (RTDs, thermocouples, PRTs) at cryogenic levels.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-F, 75 Ohm
85039B
-
The Keysight 85039B calibration kit, with option M0F, contains male and female type-F open, short, and load standards. This calibration kit works with all 75 ohm network analyzers and test sets for measurement of devices with 75 ohm type-F connectors. The kit also includes type-N to type-F adapters. More economical versions of this kit are available by ordering option 00F for the female standards only, or option 00M for the male standards only. This kit is specified from dc to 3 GHz.
-
Product
Calibration Blocks
-
Are used to assess and refine measurement equipment's correctness, and these calibration blocks come in various sizes and shapes.
-
Product
Coaxial Calibration Kits
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Rosenberger offers the following types of calibration kits with a range of coaxial connector series for vector network analyzers (VNAs). All Rosenberger calibration kits can be used from DC to their maximum frequency. Full version with adaptors and sliding loads for variable measurements Industrial version for standard measurements LRL and TRL version
-
Product
Solution Standard Reference Materials
-
NCS Testing Technology Co., Ltd.
Solution Standard Reference Materials by NCS
-
Product
Reference Standards
GF333V2
-
Beijing GFUVE Electronics Co.,Ltd.
Standard kWh meter is a reference standard with the characteristics of wide-range, multifunction and high-precision. It has accuracy class of 0.02. By adopting techniques of DSP, embedded system and automatic temperature balancing and other compensation, it has not only advantages of light weight, small size, high precision, high performance, powerful function, original interface, ease-to-use, but also work stability.The product can be widely used in fields of electric energy measuring, electric energy laboratories and other relevant industry, not only in laboratories but also at the industrial field.
-
Product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
-
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
Product
Force Calibration
-
Trescal provides full Force Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Force Calibration services can be delivered at your site or at our lab. Accreditations for our force calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
ATE / Bench Calibrators & Multimeters
-
Time Electronics offer a range of precision calibrators and digital multimeters that can be used in the lab or in automated testing applications. These programmable instruments are designed for precision, performance, and functionality, making them ideal for automatic testing and fault diagnosis. Each designated ATE calibrator is rack mountable for straightforward integration into user systems.
-
Product
Standard Panel & Display Products
-
Standard Panel & Display Products by Teledyne Defense & Electronics
-
Product
Automated Temperature Resistance Standard
-
Measurements International Ltd.
Exceptional Stability, Cost-effectiveness, Performance-based Results, 10 Ω, 25 Ω, 100 Ω, 200 Ω, 400 Ω and 1000 Ω Internal Standards, Built-in Temperature Chamber for Optimal Performance.
-
Product
Temperature Calibrators
-
Highly accurate dry well temperature standards designed for testing and calibrating a broad range of thermometers, temperature sensors, thermocouples, RTDs and temperature switches used in military and industrial applications.
-
Product
Standard Capacitors
1408 Series
-
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.
-
Product
DC Power Source for Standard Lamp
DC502
-
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA