IEPE Microphones
measure acoustic frequency, time and noise levels.
-
Product
Signal Conditioners
-
Metra Meß- und Frequenztechnik Radebeul GmbH & Co. KG
Metra has been manufacturing amplifiers for piezoelectric transducers for over 50 years. We offer economic charge amplifiers and signal conditioners for IEPE transducers including microphones.
-
Product
Measurement Microphones
-
The microphone bodies contain the preamplifier. They combine high dynamic range and wide frequency range with low noise. These measurement microphones connect via the ASD Cable to the XL2 Audio and Acoustic Analyzer, e.g. for measurements at remote locations or to reduce acoustic reflections.
-
Product
IEPE Impact Hammers
-
Our range of general purpose IEPE impact hammers offer a range of great cost effective solutions for a majority of applications requiring the excitation of a structure. The most common application being Modal testing whereby the structure is excited using the impact hammer and the response of the structure is measured using accelerometers. However instrumented hammers can also be used for crack detection and other structure related investigations.
-
Product
Microphone preamplifier
PRE-01
-
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Microphones
-
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
Product
Microphones
-
MIC-01, MIC-02 and MIC-03 are low cost precision condenser electret microphones perfectly suited for laboratory and on-field acoustical measurements. They have identical performances but differ for their physical size; MIC-01 is preferable for fixed laboratory installations while MIC-02 is highly manageable due to its short length; MIC-03 is the best where space saving is a must. Their frequency response is individually tested against specifications and the sensitivity value is supplied. MIC-01 & MIC-02 & MIC-03 can be directly connected to your CLIO system's input.
-
Product
Microphone Interfaces
MEMS
-
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
Product
Special microphones
-
G.R.A.S. Sound & Vibration A/S
Special microphones are often required for applications where there are particular requirements regarding the methods of measurements and configurations
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
Microphone Preamplifier
426A30
-
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
Product
Precision Condenser Microphone
377C10
-
Performance:Nominal Microphone Diameter:1/4"CharacteristicPressure Open Circuit Sensitivity1.0 mV/Pa1.0 mV/PaFrequency Range (2 dB)4 to 70000 Hz4 to 70000 Hz Lower Limiting Frequency (-3 dB)0.25 to 3.0 Hz0.25 to 3.0 Hz Resonant Frequency (90 Phase Shift)65000 Hz65000 HzHumidity Coefficient of Sensitivity (0 to 100%, non-condensing)0.0012 dB/%RH0.0012 dB/%
-
Product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
-
Portable, self-contained, high-intensity acoustic microphone calibration source
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Measurement Microphone System
7052SYS
-
The 7052SYS Type 1.5TM measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 4 Hz to >20 kHz response, 20 mV/Pa sensitivity and a "A" weighted noise floor less than 20 dBA.
-
Product
23KHZ Measurement Microphone
M23
-
The M23 is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
Ultrasound Microphone
M500
-
The M500 microphone is easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic signals with the highest quality. For recording with the M500, the BatSound Touch or BatSound Touch Lite software is used.
-
Product
HEAD artificial head microphones
HSU III
-
The HEAD-Shoulder-Unit HSU III is an artificial head microphone for binaural recordings.
-
Product
Precision Condenser Microphone
377B02
-
1/2" free-field, prepolarized condenser microphone, typical sensitivity= 50 mV/Pa (+/-1.5 dB), 3.15 Hz to 20 kHz (+/-2 dB).
-
Product
Precision Condenser Microphone
377C41
-
1/2" condenser microphone, free-field, 200 V Polarization
-
Product
Electret Measurement Microphone
EMM-6
-
The EMM-6 is a precision electret condenser microphone designed for measurement and critical recording applications. The extremely flat frequency response and true omni-directional polar pattern make it perfect for use with room acoustic analyzers and audio measurement systems. The EMM-6 microphone is individually hand calibrated using a laboratory standard Brüel & Kjær microphone in conjunction with a DAAS computer measuring system. Each microphone includes stand mount, foam windscreen, transport case, and its own unique calibration response graph.
-
Product
50KHZ MEASUREMENT MICROPHONE
M50
-
The M50 is a precision engineered 50kHz omnidirectional measurement microphone ideally suited for acoustical measurements including high-end loudspeaker design and quality control, scientific research, measurements of ultrasonic or subsonic transducers, or any application where an extremely accurate free-field measurement microphone is required.
-
Product
Precision Condenser Microphone
377C01
-
Performance:Nominal Microphone Diameter:1/4"Open Circuit Sensitivity 2.0 Open Circuit Sensitivity (3 dB)-54 dB re 1 V/PaFrequency Range Inherent Noise<35 Temperature Coefficient of Sensitivity (+14 to +122FHousing Material: Stainless Alloy
-
Product
Microphone Pre-Amp Audio Interfaces
-
Analog Devices mic pre-amp audio interfaces provide a high fidelity, high performance solution for audio products. Specifications for this family include ultralow 1.5 dB noise figures, 140 dB gain range, and high gain capability. Operating in an extended industrial temperature range of –40°C to +85°C, this portfolio of mic pre-amp audio interfaces supports many applications, including precision instrumentation, active filters, low noise amplifier front ends, surveillance systems, computerized voice recognition, and a variety of other industrial and consumer products. As the first choice for serious audio engineers, Analog Devices mic pre-amp audio interfaces can give your applications the performance needed to meet the most demanding specifications.
-
Product
ICP Microphone System
HT378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Precision Condenser Microphone
378A12
-
1/4-inch pressure prepolarized 377A12 microphone, with 1/4-inch preamplifier 426B03 and TEDS v0.9
-
Product
Precision Condenser Microphone
2575
-
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Product
PROBE MICROPHONE ICP
377B26
-
Open Circuit Sensitivity (at 250 Hz)Frequency Range (+2.2/-4.9 dB)2 to 20000 HzLower Limiting Frequency (-3 dB)Inherent Noise<45 dB(A) re 20 Pa Dynamic Range(3% Distortion Limit)EnvironmentalTemperature Range (Operating)-40 to +158 F-40 to +70 C[5]
-
Product
IEPE Triaxial High Sensitivity Accelerometer 10V/g
HDBV-1000
-
HDBV-1000 is a tri-axial accelerometer for the measurement of human exposure to whole-body vibrations, according to ISO 2631 and ISO 8041.