ICP Microphones
measure acoustic frequency, time and noise levels.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
-
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
Product
For accurate testing of headphones, microphones telephones and loudspeakers
Artificial Mouths, Ears, and Couplers
-
Listen supplies artificial mouths, ears and ear couplers from Brüel and Kjær, GRAS and more.
-
Product
Measurement Microphones
-
The microphone bodies contain the preamplifier. They combine high dynamic range and wide frequency range with low noise. These measurement microphones connect via the ASD Cable to the XL2 Audio and Acoustic Analyzer, e.g. for measurements at remote locations or to reduce acoustic reflections.
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
XRF, AA & ICP sample preparation
Claisse Range
-
Designed for unprecedented analytical accuracy and repeatability, Claisse® electric and gas automatic instruments set new benchmarks in fusion capabilities. The same is true for Claisse pre-fused and homogeneous borate fluxes, high-quality platinumware, as well as analytical consulting services.
-
Product
Microphone Preamplifier
426B03
-
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
Product
USB Microphones
-
Easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic Is esignals with the highest quality.
-
Product
ICP-MS spectrometers (ICP MASS)
-
SPECTRO Analytical Instruments GmbH
SPECTRO MS is a double-focusing sector field ICP MS (ICP mass spectrometer) based on a Mattauch-Herzog geometry with a newly developed ion optic and pioneering detector technology. It is the only ICP MS instrument available on the market today that is capable of simultaneously measuring the complete mass range used for inorganic mass spectrometry from 6Li to 238U with a permanent ion beam going to the detector.
-
Product
Precision Condenser Microphone
2575
-
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Product
30KHZ Measurement Microphone
M30
-
Used on countless full-scale concert tours, as well as in scientific research laboratories, tropical rainforests, and rocket testing facilities, the M30 has proven to be a lab-grade audio instrument that can handle any environment.
-
Product
ICP® Accelerometers With Excellent Thermal Stability
-
The single and triaxial ICP® accelerometers are designed with a low temperature coefficient, wide operating temperature range, and good broadband measurement resolution, making them ideal for any vibration measurement requiring tight control of amplitude sensitivity over a wide thermal gradient. To alleviate the effects of high frequency overloads caused by metal-to-metal inputs, a low pass filter has been incorporated in all models, ensuring accurate data in the frequency range of interest.
-
Product
Low Outgassing ICP® Accelerometers
-
Low Outgassing ICP® (IEPE) Accelerometer Types & Their Applications.
-
Product
Type 1 Phantom Powered Measurement Microphone
MK224PH
-
The MK224PH Type 1 phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Frequency Response: +/-2dB (8 Hz to 18kHz). Sensitivity: 50 mV/Pa (-26 dBV/Pa)typ. Dynamic Range 3% THD: 14dBA-145dB.
-
Product
Ground Isolated ICP® Pressure Sensors For High Frequency
-
PCB® Series 102B is a ground isolated version of the Series 113B. These sensors have all of the same features and benefits of the 113B Series, plus the added benefit of isolation, which helps prevent ground loop problems. This series can accommodate an optional ablative coating (Prefix: CA) to protect the diaphragm from thermal shock in flash-temperature applications.
-
Product
Microphones
-
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
Product
Precision Condenser Microphone
377C10
-
Performance:Nominal Microphone Diameter:1/4"CharacteristicPressure Open Circuit Sensitivity1.0 mV/Pa1.0 mV/PaFrequency Range (2 dB)4 to 70000 Hz4 to 70000 Hz Lower Limiting Frequency (-3 dB)0.25 to 3.0 Hz0.25 to 3.0 Hz Resonant Frequency (90 Phase Shift)65000 Hz65000 HzHumidity Coefficient of Sensitivity (0 to 100%, non-condensing)0.0012 dB/%RH0.0012 dB/%
-
Product
Sub-Miniature ICP® Pressure Sensors
-
PCB's sub-miniature 105C dynamic pressure sensors are specifically designed to fit into tight spaces where mounting space is at a premium.
-
Product
PCB Triaxial Accelerometer, 1000mV/g, ICP®(IEPE), 0.5Hz-3kHz
784815-01
-
The PCB Miniature Triaxial Accelerometer helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB Miniature Triaxial Accelerometer features a sensitivity range of 1000 mV/g and requires the PCB lightweight cable with 4-socket plugs.
-
Product
Ultrasound Microphone
M500
-
The M500 microphone is easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic signals with the highest quality. For recording with the M500, the BatSound Touch or BatSound Touch Lite software is used.
-
Product
ICP Blast Pressure Pencil Probe
Model: 137B21B
-
Quartz, free-field, ICP blast pressure pencil probe, 1000 psi, 1 mV/psi, BNC connector
-
Product
Measurement Microphone System
7052SYS
-
The 7052SYS Type 1.5TM measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 4 Hz to >20 kHz response, 20 mV/Pa sensitivity and a "A" weighted noise floor less than 20 dBA.
-
Product
Multitype ICP Emission Spectrometers
ICPE-9800 Series
-
Due to their high detection sensitivity down to ppb levels, ability to analyze a broad 5 to 6-digit range of concentrations, and ability to measure multiple elements simultaneously, ICP emission spectrometers are used in a broad range of fields, such as environmental testing, pharmaceuticals, foods, chemicals, and metals. ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels. They also feature user-friendly software that makes analysis easy. Furthermore, the systems reduce analysis costs while providing the highest performance levels in the industry. ICPE-9800 Series systems represent the ultimate in ICP atomic emission spectrometry for environmental, pharmaceutical, food, chemical, metal, and other fields.
-
Product
Modern Prepolarized Precision Condenser Microphones & Preamplifiers
-
Modern prepolarized microphones are designed with newer technology than traditional externally polarized microphones. Prepolarized microphones have many advantages over the externally polarized models. They use ICP® power circuitry invented for sensors by PCB®. By applying a polymer coating to the top of the backplate and embedding a charge on it, expensive 200V power supplies can be eliminated and 2-20 mA constant current supplies or signal conditioners can be used as the power source.
-
Product
Cryogenic ICP® Accelerometers
-
Cryogenic ICP® accelerometers are specifically designed to operate at temperatures below the typical -65 ºF (-54 ºC) temperature limit of most voltage mode sensors. The use of specialized, built-in, cryogenic circuitry and quartz shear sensing technology promote survivability in demanding environments such as liquid nitrogen. Each sensor is hermetically sealed and individually tested to determine the thermal coefficient of sensitivity at -320 ºF (-196 ºC) ensuring reliable operation and accurate measurements. These sensors have been successfully used in the presence of liquid helium during structural testing of rocket boosters.
-
Product
2 Channel Microphone Power Supply and Conditioning Amplifier
SoundConnect 2 mic power supply
-
SoundConnect 2 is a rugged 2-channel USB controlled microphone power supply and conditioning amplifier.
-
Product
USB Controlled Loudspeaker & Microphone Test Interface
AmpConnect™ ISC
-
AmpConnect ISC is an all-in-one audio interface that simplifies your test setup and operation. It is a single, rugged, rack-mountable piece of hardware containing a high-accuracy audio interface, impedance box, amplifier, headphone amplifier, 2 microphone power supplies and digital I/O. It replaces multiple hardware devices, connecting to your computer via a single USB cable, and it is fully controlled by SoundCheck. This simplifies setup and calibration, eliminates cabling and reduces connectivity errors, as well as reducing overall system cost.
-
Product
HEAD artificial head microphones
HSU III
-
The HEAD-Shoulder-Unit HSU III is an artificial head microphone for binaural recordings.
-
Product
Charge Amplifier for Outputs from Piezoelectric- or mV-type Accelerometers, Force Gauges, Microphones & Pressure Pickups
Trig-Tek™ 201AP
Amplifier
Amplify the outputs from piezoelectric- or mV-type accelerometers, force gauges, microphones, and pressure pickups
-
Product
ICP® Shock Accelerometers
-
Piezoelectric ICP® accelerometers afford a very high signal output (+/- 5 volts full scale) and the ease of two-wire electrical connectivity. Their inherent ruggedness enables them to be severely over ranged without damage. The addition of internal mechanical isolation minimizes the high frequency stress that would otherwise be encountered by their ceramic sensing elements. This mechanical isolation, coupled with an internal 2-pole electrical filter, built into the ICP® circuitry, tailors the overall accelerometer response to assure data quality to frequencies as high as 10 kHz. Depending on the specific model, accelerations in excess of 50 kg can be successfully measured. These modern designs, with their internal elastomeric isolation materials are verified through calibration to remain dynamically linear and are enabling piezoelectric accelerometers to operate in increasingly severe acceleration environments.
-
Product
Microphone preamplifier
PRE-01
-
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage