Product
Mineral Insulated RTD / RTD Probe With Extension Lead
-
Mineral Insulated Resistance Thermometers are for use up to 500°C depending on the configuration. They are rugged, steel sheathed probes with flexible sheaths allowing bending or forming. They offer long life (depending on use) are resistant to vibration
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
PXI RTD Simulator Module, 16 Channel, PT1000
40-263-203
Simulator
The 40-263-203 is a 16-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
RTD Thermometer
-
Tel-Tru® Manufacturing Company
Tel-Tru RTD probe assemblies and RTDs integrated with a compact transmitter are designed for precision temperature measurement in demanding sanitary or industrial environments. RTDs are configurable with many options to meet the needs of dairy, beverage, food, pharmaceutical and chemical processing applications.
-
Product
4 2/3 Digital Temperature (RTD) Meter
CS2-T
-
CS2-T Temperature Indicator has been designed with high accuracy measurement, display and communication of Thermocouple or Pt100Ω.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments application.
-
Product
PXI RTD Simulator Module 18 Channel PT100
40-262-001
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
Product
PXI RTD Simulator Module, 4 Channel, PT100
40-263-501
Simulator
The 40-263-501 is a 4-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
RTD Simulator PCI Card 6-Channel PT1000
50-262-102
Simulator
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card can provides a setting resolution of <90mΩ (also available in <8mΩ - PT100) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
Temperature Input Module
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
PXI RTD Simulator Module, 8 Channel, PT100
40-263-401
Simulator
The 40-263-401 is an 8-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PCI RTD Simulator Card 6-Channel PT100
50-262-101
Simulator
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card provides a setting resolution of <8mΩ (also available in <90mΩ - PT1000version) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
RTD Data Logger
-
RTD Data Logger is the most commonly used sensors for measuring temperatures in various industries. These are positive temperature coefficient resistive sensors and Pt100 is the most commonly used type of RTD sensor which has 100 ohm resistance at 0 C. IM2000 series RTD data loggers offer bridge measurement technique to compensate for effect of wire length. In addition logger has facility to program offset so that the measurements are more accurate.
-
Product
PXI RTD Simulator Module, 12 Channel, PT1000
40-263-303
Simulator
The 40-263-303 is a 12-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module, 4 Channel, PT500
40-263-502
Simulator
The 40-263-502 is a 4-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
Platinum Wire Electrode – 0.1–1.0 Mm Diameters
PEE1
-
High-purity platinum wire (99.99%) designed for flame tests, water electrolysis, and general electrochemical research. Featuring excellent conductivity, corrosion resistance, and thermal stability, platinum wire provides a chemically inert support that does not interfere with flame colors or electrochemical reactions. Available in diameters from 0.1 mm to 1.0 mm, with custom lengths and configurations available.
-
Product
RTD Measurement for CompactPCI
CPCI390
-
The CPCI390 has a 3U form factor and features six 2-, 3-, or 4-wire high-accuracy RTD measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued. The local DSP (TMS320C203) performs linearization, auto-calibration and alarm limit checking. Sensordata is available in °C, °F, K and Ohm. All inputs are optically isolated from the system.
-
Product
Platinum Electrodes – Multiple Configurations & PEEK Housing Options
PEM1
-
High-purity platinum electrodes available in mesh, wire, coil, ring, rod, disc, and sheet formats. Suitable for CV, LSV, EIS, electrocatalysis, electrolysis, corrosion testing, and fuel cell research. Optional PTFE or PEEK insulation, multiple sizes, and custom configurations support a wide range of electrochemical applications.
-
Product
Platinum Interdigitated Electrode On Quartz
RIE1
-
Quartz-based platinum IDE for gas sensing, biosensing, MEMS, photoelectric, and electrochemical applications.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
4 2/3 Digital Temperature (RTD) Meter (1/32 DIN)
CS3-TR
-
CS3-TR Temperature Indicator has been designed with Pt100 (3 wire) high accuracy measurement.A compact body design for small equipment, laboratory instrument, and others.Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.
-
Product
Pure Platinum Sheet Electrodes
PPS1
-
99.99% pure platinum sheet electrode with excellent corrosion resistance and stable electrochemical performance. Suitable for electrochemical research, corrosion testing, electrocatalysis, and laboratory instrumentation. Available in multiple thicknesses, sizes, and custom shapes.
-
Product
PXI RTD Simulator Module, 24 Channel, PT500
40-263-002
Simulator
The 40-263-002 is a 24-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Wireless Precision RTD Based Temperature Data Logger with LCD
RFRTDTemp2000A
-
The RFRTDTemp2000A is an RTD-based, wireless temperature data logger with display. This data logger is ideal for applications that require high accuracy temperature monitoring such as within laboratories, pharmaceutical and biotech industries. The RFRTDTemp2000A accepts 2, 3 or 4 wire 100Ω platinum RTD’s and features a device accuracy of +/-0.5°C.
-
Product
Miniature In Head RTD/ Slidewire Temperature Transmitter
HTR200
-
The HTR200 ‘smart’ transmitter is designed for use with RTD or Slidewire sensors. It is integrated into the MA style head making it ideal for applications where space is restricted
-
Product
PXI RTD Simulator Module, 16 Channel, PT500
40-263-202
Simulator
The 40-263-202 is a 16-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
Ruthenium Iridium / Iridium Tantalum / Platinum Titanium Electrode
RRC-1
-
Ruthenium/iridium-based titanium anodes with high corrosion resistance and stable electrochemical performance. Suitable for electrolysis, electroplating, wastewater treatment, and research applications. Custom coatings, geometries, and Ti plate/mesh formats are available.
-
Product
Thermocouple & RTD Termometers
-
Amprobe thermocouple thermometers give you a professional way to measure, monitor and log temperature. Eight models let you choose the accuracy and feature set you need. For superior accuracy and stability in a process environment, choose an Amprobe RTD thermometer.