Fault Location
Determine the location of faults.
-
Product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Saluki S2107 Series Optical Cable Identifier (up to 36dB)
-
S2107 Series Optical Cable Identifier is an intelligent instrument designed for the construction and maintenance of optical cable lines in optical communication system. In view of the complex wiring environment and the difficulty of locating faults during the construction and long-term use of optical cables, S2107 series can provide fast, effective and accurate fault solutions. When the target optical cable is bent or shaken, the optical cable census instrument can quickly capture the vibration signal and display it through waveform and sound, so as to locate the target optical cable quickly.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-301
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-012
Fault Insertion Unit
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-194A-002-HI
Fault Insertion Unit
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-212
Fault Insertion Unit
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A, Hardware Interlock
40-192A-012-HI
Fault Insertion Unit
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
Fault Insertion Unit
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
Fiber Visual Fault Locator
-
Fiber visual fault locator is a pen type device which is able to locate the breakpoint, bending or cracking of the fiber glass,this small fiber optic equipment can locate the fault of OTDR dead zone and make fiber iIdentification from one end to the other end .
-
Product
21-Ch 6A-250VA 2-Bus Fault Insertion
YAV90077
Fault Insertion Unit
21 channels 1 thread 6A 250V 2 Fault Insertion Buses Switching up to 250W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
Fault Insertion Unit
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
Locators
EZiSYSTEM xf-Series
-
The EZiSYSTEM xf-Series utility locating and tracing equipment makes locating buried utilities easy and efficient. The xf-Series locators have additional low frequencies enabling you to locate and trace utilities over longer distances and in congested environments. With an EZiCAT locator there is no need to manually adjust the sensitivity. With the unique Automatic Pinpointing feature, users can hold press the trigger and start locating.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
Utility Locator
VM-850
-
Using the correct frequency makes a world of difference when locating buried utilities. The depth of the utility, size, material, and amount of congestion (proximity of other utilities) all need to be taken into consideration for the correct frequency selection. Large diameter, direct buried pipes with bell housing ends that use insulators and rubber gaskets, such as water or gas require a higher frequency while smaller diameter, well-grounded direct buried or long distance in conduits work, better with a lower frequency. The VM-850 operates at a much lower frequency of 9.82kHz which is ideal for smaller diameter utilities such as CATV, power and telephone with less bleeding onto adjacent services.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Static Locator
983v2
-