Filters
Electronic circuits which refine signal by blocking certain frequencies, while allowing other frequencies to pass.
See Also: Filter / Amplifiers, EMI Filters, Low Pass Filters, Programmable Filters, Attenuators
-
Product
PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device
778758-03
-
100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
Ethernet/LXI digitizerNETBOX 16 Bit High Speed Digitizer - 180 MS/s on 2 Channels, 2 Single-Ended Inputs
DN2.447-02
-
The digitizerNETBOX DN2.44x series allows recording of one, two, four or eight synchronous channels with sampling rates of 130 MS/s up to 500 MS/s. These products offer outstanding A/D features in resolution, bandwidth and speed as a remote instrument. The powerful A/D amplifier section offers six different input ranges, two input paths, AC/DC coupling and noise reduction filters.
-
Product
Tunable Filters - Digitally Controlled
-
K&L Microwave offers a variety of Tunable Filter Products to satisfy a broad range of filtering applications. Tunable Bandpass and Bandreject filters provide the best solution for pre-tuning the desired signals while rejecting the interfering signals. The method of tuning can be either mechanical via a tuning knob mounted on the front of the filter, or electro-mechanical via an optional remote digital interface such as GPIB, RS-232, RS-422, BCD, ARC171, ARC234, Ethernet, USB or "Thumbwheel" panel mount.
-
Product
Radar Front Ends
FMCW
-
The transmit signal is derived from an external VCO signal, internally multiplied, which also acts as the LO for the receive mixer. The resulting IF is conditioned for gain and filtering as required. The IF also contains an industry leading IF noise figure, especially in the frequency range below 500MHz. Custom designs available, visit our custom design page for more information.
-
Product
Standard Lifetime Measurement System
Filter-Based Systems
-
*Excitation by bh ps Diode Lasers (BDS-SM or BDL-SMN Series)*Optional: fs Fiber Laser*Wavelength Selection by Filters*Detection by bh HPM-100 Hybrid Detectors*Excellent Dynamic Range*Ultra-High Time Resolution*IRF Width Down to 40 ps FWHM with HPM-100-06/07*Low Cost Detector Option: PMC-150 PMT Modules
-
Product
Filters and Compiners
-
Combine four bands to a common line Multiple broadband configurations, including AWS High power handling with low IM and insertion loss AISG 2.0 compliant
-
Product
ARINC 429 Test And Simulation USB Module
USB-429
-
*4, 8 or 16 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*Sorting according to SDI field*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
Product
NI-9211, 4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input Module
779001-01
-
4-Channel, 14 S/s/ch, ±80 mV C Series Temperature Input ModuleThe NI‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Full Band Down-Converters
STC-20-10-S1
-
Full band down-converters are designed to convert high frequency millimeterwave signals down to the baseband at 10 MHz to 1.6 GHz. These down-converters deliver a superior performance since they are assembled with SAGE Millimeter’s instrumentation grade components, such as multipliers, amplifiers, filters, isolators, and more. The below standard offering covers the frequency range of 26.5 to 170 GHz and delivers a typical LO power of 3 dBm and conversion gain of 20 dB. The down-converters provide low harmonic levels and excellent gain flatness, making them ideal for test instrumentation applications. Specifications other than those listed below are available upon request.
-
Product
Low-PIM, High-Power Filter Solutions for Monitoring Broadband Emissions
-
Enables monitoring of PIM to 13 GHz; 100W CW and 1KW peakNear-end monitoring: Carriers rejected -90dB by the notchtravel through the bandpass filter to the low PIM termination.Far-end monitoring: Carriers rejected -90dB by the highpass,IM products passed are monitored by the spectrum analyzer.
-
Product
Dual Adjustable Lowpass Filter
LTC6603
-
The LTC6603 is a dual, matched, programmable lowpass filter for communications receivers and transmitters. The selectivity of the LTC6603, combined with its linear phase, phase matching and dynamic range, make it suitable for filtering in many communications systems. With 1.5° phase matching between channels, the LTC6603 can be used in applications requiring pairs of matched filters, such as transceiver I and Q channels. Furthermore, the differential inputs and outputs provide a simple interface for most communications systems.
-
Product
Dual Channel Multi-Band FM Tracking/Data Receiver In Modular Style Housing
LS-27-B
-
The Lumistar LS-27-B Modular Dual Channel Tri-Band Tracking and Data Receiver is Lumistar’s third generation of modular high performance FM Receivers. This wideband designs supports one or two independent channels of PCM with data rates up to 20Mbps. The unit includes both an optional FM demodulated output for PCM data, and standard programmable AM/linear AGC outputs for auto-tracking receivers. The design offers 8 IF Bandwidths and 8 Video Filters per channel for each receiver.AC coupling with a low pass filter is employed to ensure a high quality data link with long strings of NRZ-L ones or zeroes. The unit provides a software selectable 10 MHz reference I/O port forlocking local oscillators to a high precision external source or to arrange multiple units in a master/slave arrangement. The receiver’s control and status is achieved via Ethernet, USB or auto-switched RS-232 (or “4-wire” RS-485 in place of 232). When utilizing the RS-422 interface, multi-drop configurations can be accommodated.
-
Product
4-Ch High Speed Counter/Frequency Module
ADAM-5081
-
Minimum Pulse Width: 1μ sec. (Frequency/Counter Mode)Function Mode: Counter (Up/Down, Bi-direction, Up, A/B Phase) FrequencyInput Frequency: Frequency Mode: 5Hz ~1MHz Counter Mode: 1MHz max.Isolated Voltage: 2500 VdcProgrammable Digital Noise Filter: 1~65000μ sec.4 channels for Counter, 8 channels for FrequencyCounter Aux. Function: Initial preset, hi-low alarm setting, alarm digital output mapping, overflag
-
Product
Temperature Input Module For Remote I/O
-
The Temperature Input Module for Remote I/O features a features a thermocouple input range of ±100 mV and a voltage input range of ±5 V. It also has an adjustable filter time for improved measurement quality and optional external CJC or PT100 RTD measurements.A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the Temperature Input Module for Remote I/O from a real‐time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low‐cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high‐speed or specialty measurements.
-
Product
Data Acquisition DSP based 16 channel
-
The CPCI-AD8/16 module provides a 3U high performancedata acquisition subsystem. There are (8) eight or (16)sixteen 100/200 KSPS ADC’s for maximum performance.The Local DSP can be used to simply move data samplesto the CPCI bus or can provide processing functions suchas limit checking, FFT’s, digital filtering, etc. Software canbe downloaded to the DSP via the CPCI interface.Instrumentation amplifiers provide over-voltage protectionand gain on a per channel basis. The CPCI-AD8/16 canalso accept external scan and trigger signals from a frontpanel connector
-
Product
Optical Balloon Theodolite
-
F. W. Breithaupt & Sohn GmbH & Co.KG
*Robust instrument*Bright scope with wide field occular and fix focus*Magnification 16x (20x optional)*Field of view 55,6m/1000m (optional 27,8m)*Open finder sights*Double vertical circles (reading from both sides of the instrument)*Reading of circles 0,1°*Convenient targeting through friction-controlled by endless wormdrive screws*Accessories upon request like alarm clock, filters, tripod etc.*Long life cycle, full spare part availability*Made in Germany
-
Product
Optical Filter Sets
-
Our filter sets support a great range of fluorophores for microscopes and imaging systems. Patented design techniques drive some of the most spectrally sophisticated optical filters on the market. High transmission, steep edges, precise spectral edge placement, and optimized blocking combine for more reliable measurements. A wide selection of individual bandpass filters and dichroic beam-splitters support unique applications, and world-class manufacturing and cutting-edge metrology ensure consistent performance that always meets specifications.
-
Product
Solid State Broadband High Power Amplifier 1900 - 6000 MHz / 200 Watts
2215
-
The 2215 is suitable for octave bandwidth high power CW, modulated and pulse applications. This amplifier utilizes high power GaN devices that provide wide frequency response, high gain, high peak power capability and low distortions. Exceptional performance, long-term reliability and high efficiency are achieved by employing advanced broadband RF matching networks and combining techniques, EMI/RFI filters, and all qualified components. for EMC, RF Product Test, Communications and Electronic Warfare applications.
-
Product
Ethernet Adapter Supporting up to Twenty ARINC-429 Channels in Any Combination
ES-9810/A0 (RUNET II)
-
The EXC-9810/Ax is an Ethernet adapter supporting up to twenty ARINC-429 channels in any combination of transmit and/or receive. All of the channels feature error injection and detection.adapter. Its small size and ability to interface through Ethernet interfaces make it a complete solution for developing, testing and performing system simulation of the ARINC-429 bus, both in the lab and in the field.The receive channels allow for the storage of all selected labels with status and time tag information appended to each word, and also allow for filtering and multi-storage modes of data words. The transmit channels operate via a transmit ‘instruction stack’ which allows scheduling of data transmissions and reduces the need for host computer intervention. The EXC-9810 supports up to four independent 8000 family avionics communication modules, allowing multiple different protocols to be mixed and matched on a single card. Modules available include MIL-STD-1553, MIL-STD-1760, MMSI, ARINC-429, ARINC-708, ARINC-717, Serial, Discrete and CAN bus. In addition, multiple units can operate on the same network, by programming each one with a unique IP address, and can be accessed from any computer on the network.The EXC-9810/Ax adapter is supplied with C drivers, including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application (only versions 8.1 or higher). Please see multi protocol 8000 modules for additional information on protocols that can be added to this card.
-
Product
IP-Parallel-IO
-
IP Compatible card with 48 programmable TTL IO or 24 - RS422 / RS485 compatible differential pairs. 5 mixed combinations available. Filtered or direct input. Programmable interrupt from each IO [TTL or differential]. 2 counter timers. Waveform generator.
-
Product
Photometer
Optronik Line DSP 200
-
Instrument Systems Optische Messtechnik GmbH
DSP 200 offers outstanding sensitivity and stability for precise measurements even at very low illumination levels. The instrument meets, of course, all requirements of the newest standards, like EN 13032-1 and DIN 5032-7 (2017). A low-noise photo diode with V(lambda)-filtering and optimized electronics provides for a broad dynamic range from 0.1 mlx to 200 klx. At the same time the very high local resolution allows an accurate determination even of high gradients when measuring headlamps. Therefore, the DSP 200 is suitable for all automotive and traffic applications, as well as for flashlights and for measurements of all pulse width modulated light sources.
-
Product
Microphone preamplifier
PRE-01
-
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
Product
PXIe-5162, 1.5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope
782622-11
-
PXIe, 1.5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope—The PXIe-5162 high-speed oscilloscope device has two or four channels that sample at up to 5 GS/s with flexible settings for coupling, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require up to 1.5 GHz of analog bandwidth and flexible measurement configurations.
-
Product
RF Front-end
-
The RF integrated passive device (RF IPD) uses a high-resistivity substrate to integrate quality factor components such as capacitors and indictors. Many functions like impedance matching networks, harmonic filters, couplers, baluns, and power combiners/splitters can be designed using IPD technology. ST's IPDs are manufactured using thick film and HiRes Si or glass wafer manufacturing technology and photolithography processing.
-
Product
Loggers/PQA
-
Kyoritsu Electrical Instruments Works, Ltd.
Large capacity for storing 60,000 data points Lowpass Filter will filter out the harmonics LED flickers when the preset current/voltage value is exceeded CALL:Confirmation of recorded data Selection of One-time mode or Endless mode Non Volatile Memory Battery power indicator The userfriendly PC software "KEW LOG Soft 2" is supplied Continuous measuring time:Approx. 10 days (Alkaline Battery)
-
Product
Plastic And Reconstructive Surgery Microscopy Solutions
-
Leica plastic and reconstructive surgery (PRS) microscopes give you the performance and reliability you need to repair intricate and fine structures during the most delicate reconstructive procedures. They feature high-quality optics, easy operation, and integrated visualization technologies, such as fluorescence filters and augmented reality (AR) fluorescence.
-
Product
PCI-5124 , 150 MHz Bandwidth, 200 MS/s, 12-Bit PCI Oscilloscope Device
779171-03
-
150 MHz Bandwidth, 200 MS/s, 12-Bit PCI Oscilloscope Device—The PCI-5124 high-resolution oscilloscope device has two channels that sample up to 200 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution measurements with up to 150 MHz of analog bandwidth.
-
Product
128-Ch Isolated Digital I/O PCIE Card
PCIE-1758
-
Interrupt handling capability for each channel128 isolated digital output channels (64 channels for PCI-1758UDIO)High-voltage isolation on output channels (2,500 VDC)Wide output range (5 ~ 40 VDC)High sink current for isolated output channels (350 mA max./channel)BoardID™ switchDigital output value retained after hot system resetPCIE-1758DI and PCIE-1758DIO128 isolated digital input channels (64 channels for PCI-1758UDIO)Wide input range (10 ~ 30 VDC)High ESD protection (2,000 VDC)Digital Filter functionPCIE-1758DO and PCIE-1758DIO
-
Product
PXIe-4304, 24-Bit, 32-Channel, 5 kS/s, 42 V, PXI Analog Input Module
783867-01
-
24-Bit, 32-Channel, 5 kS/s, 42 V, PXI Analog Input Module—The PXIe‑4304 is a filtered analog input module for higher voltage measurements. The module offers the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.