Current
See Also: Direct Current, Alternating Current, Resistivity, Flow, Inductance
-
Product
5000 Watt System Power Supply, 40V, 128A
6684A
Power Supply
Keysight high performance DC power supplies offer speed and accuracy for test optimization. The single output, 5000W, GPIB 6680A-6684A provide low output ripple and noise; selectable compensation for inductive loads; analog control of output voltage and current; and fan-speed control to minimize acoustic noise.
-
Product
4 Channels DC Power Data Acquisition Device
NuDC-4U
-
NuDC-4U is an innovative product that provides better solution for power probing. Common DC power statistics including voltage, ampere and even the watt can be read instantly via NuDC-4U. Moreover, up to 4 sets of individual powers can be monitored simultaneously and the LCD screen can also display the maximum and minimum value of the current power during the test.
-
Product
SCR Rectifiers
-
SCR-controlled rectifiers are electronically controlled via analog signals for constant voltage and current control. The compact and service-friendly design complies with high industrial requirements and guarantees excellent operational reliability.The input voltage can be from 208 VAC to 600 VAC, 3 PH, 50/60 Hz. Maximum output voltage can be from 6 VDC to 600 VDC. Maximum output can be from 1000 Amps to 100000 Amps. These units can be air cooled, water cooled or oil cooled.
-
Product
Three Phase Power Calibrators And Tester Of Power Engineering Devices
C300B
-
Calmet Smart Calibration Devices
Three phase, class 0.02 and 0.05 power quality calibrator up to 120A (360A) and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L18-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Manual-Hardware 218 24-bit DAQ (DMM) Elan/Ines PCMCIA DAQ Cards
Manual-DAQ218HW
-
*Hardware manual for current Elan/Ines 24-Bit Data Acquisiton Cards:*DAQ i218*TS-C-AD218
-
Product
Isolated DC Power Supply for PC104-PCI Express Embedded Applications
EXC-PSM104PCIe
Power Supply
The EXC-PSM104PCIe is an isolated DC power supply specifically designed to provide reliable power for highly demanding PC104-PCI Express embedded applications. The EXC-PSM104PCIe has a wide input voltage range while providing robust and reliable power for embedded and industrial motherboards. The power supply is also fully compliant with MIL-STD-704A and E, MIL-STD-1275B and MIL-STD-461E.The EXC- PSM104PCIe has totally independent safety features including input undervoltage lock-out, output overvoltage protection, output current limit protection, and temperature protection. Additionally, the Soft-Start function limits inrush current during startup.
-
Product
ABex Terminal Module for Extending the Functionality of the PXI-501
ABex TM-501 MFI
-
The ABex TM-501 is an ABex terminal module that extends the multifunction measurement card PXI-501 with additional features. It is located in front of the PXI-501 card.It expands the analog outputs voltage range of the PMUs to -10V up to +40V. Additionally it features a shunt current measurement unit to measure currents up to 500mA
-
Product
Current Probe
DCP-BTA
-
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Product
Device Current Waveform Analyzers
-
The dedicated Current Sensors measure from 100 pA level dynamic current up to 10 A with a maximum of 200 MHz bandwidth. The mainframe acquires the signal from the sensors by a maximum of 1 GSa/s sampling speed and 14-bit and 16-bit wide dynamic range. This combination allows you to measure quite wide range of dynamic current, for example, from standby/sleep state to active state, at a single measurement. In addition, the wide bandwidth and the high speed acquisition enable you to measure high speed pulse response even less than 100 ns previously very difficult with existing instruments.
-
Product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25B-10
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
MEP General Purpose Probes
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
High 3.12 (88.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-72I40-8
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Auxiliary Current Transformers
-
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
Product
Current, Voltage, Resistance
-
Solutions for the testing and calibration of current, voltage and resistance are used in industry (laboratories, production, workshops), in calibration service companies and in quality assurance. These instruments are portable and mobile and are particularly notable for their low measurement uncertainty and high scope of operation.
-
Product
PXI Single 16x4 1-Pole 5A Power Matrix
40-549-001
Matrix Switch Module
The 40-549 is a single pole power matrix module, suitable for switching inductive/capacitive loads up to 5A with 110VDC/250VAC hot switching and 400VDC/250VAC cold switching. It is available in single 16x4, single 8x8, dual 8x4 or single 8x4 configurations. Connections are made via a front panel 25 way D-type male connector. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. The module is suitable for applications requiring switching of either mains voltage or DC current.
-
Product
Portable Three-Phase Phantom Load
EE-120A-3 + EE-500V-3
-
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
Product
PXI Very High Density MUX 198 Chan 1 Pole
40-675-002-198/1
Multiplexer Module
The 40-675 series of very high density low cost multiplexer modules are available in a versatile range of switching configurations. The modules are supplied pre-configured in one of six multiplexer modes suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
DC System Power Supply, 300Â V, 2.5Â A, 750Â W
N5751A
Power Supply
The single output, 750 W N5751A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
Product
Alternate 2.14 (61.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-72I-6
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Battery Test Equipment
-
KV Hipot Power Test Equipment Co.,Ltd
Battery testers are the class of instruments designed to assess the condition—the charge, impedance, ripple current, or other measurement—of batteries to ensure they are working as required. Just as batteries have a very wide range of sizes and uses, so do battery testers.
-
Product
ZZ Power Booster 1200V/3000V
ZZ Booster-Transmitter
-
ZZ Resistivity Imaging Pty. Ltd.
*3,000W output power in 2 adjustable voltage ranges ( 400V/7.5A, 1,200V/2.5A), the FlashRES booster transmitter is particular useful for surveys in high resistive areas or IP surveys.*When the FlashRES booster transmitter is connected FlashRES-UNIVERSAL, for each current injection, the system could collect 61 voltage measurement, this greatly increases the data collection speed.*Uses two standard 12V batteries connect in series as input power source*The FlashRES booster transmitter is designed for heavy duty usage, the instrument is shock, water and dust proof.*Light-weight and easily mobilised
-
Product
PXI 2A Multiplexer, 4-Bank, 4-Channel 8-Pole
40-614-009
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
Broadband Power Amplifier
PAS-00210-80
-
* Solid State Power Amplifier* Small Signal Gain: 50 dB typ.* Rack Mount Case* Internal Cooling Fans* Type N Connectors* Over-voltage, over-current protections* Microprocessor controlled (optional)* Current monitor (optional)* Ethernet interface (optional)* Variable Gain (optional)* ALC power control (optional)
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1T30-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 3.00 (85.00) - 5.70 (162.00) General Purpose Probe
P2664G-1C2S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Circuit Breaker Analysis System
-
Weshine Electric Manufacturing Co., Ltd
1. Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.
-
Product
STP-1 Replaceable Step Probe
STP-1
Step Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 135Full Travel (mm): 3.43Full Travel Remark: Varies with tip (min. 135 mil / 3,43 mm)Recommended Travel (mil): 120Recommended Travel (mm): 3.05Overall Length (mil): 1300Overall Length (mm): 33.03
-
Product
P2664 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)