product
Exhaust Pressure Controller
EC-5000 Series
The EC-5000 series exhaust pressure controller can maintain a consistent pressure, of the user’s choice, within the chamber. The high-resolution stepper motor and unique butterfly valve ensure a fast, sensitive response to any pressure changes.
-
product
Portable Exhaust Gas Analyzer
IMR 1440FL
IMR Environmental Equipment, Inc.
The exhaust gas analyzer, IMR 1440FL/COFL, is designed to measure exhaust gases of Forklift Trucks that are powered by a variety of fuels. According to US regulations, the IMR 1440FL/COFL can measure soot and CO for Forklift Trucks. If state regulations require NOx, the IMR 1440FL/COFL can be equipped with a NOx sensor. The IMR 1440COFL is equipped with two CO sensors. One CO sensor operates in the low range and another CO sensor operates in the high range.
-
product
FTIR Motor Exhaust Gas Analyzer
MEXA-ONE-FT
The MEXA-ONE-FT Series simultaneously measures concentrations of multiple components, including NH3, N2O, CH4, CO and CO2, in undiluted exhaust gas using the Fourier transform infrared (FTIR) method in combination with a multivariate analysis algorithm. It incorporates HORIBA's proprietary compact interferometer which yields superior performance and high accuracy.The system complies with NH3 testing requirements of Euro VI, the EU regulation for heavy duty emissions testing.The MEXA-ONE-FT can be calibrated according to customer requirements with up to 6 component sets to cover a wide range of applications.FTIR spectroscopy allows the direct measurement of NO2 emissions and the independent quantification of individual hydrocarbon species. This makes the MEXA-ONE-FT system an ideal solution for detailed research and development tasks.Due to the measurement principle, the time-consuming daily span gas calibration is omitted.In addition, usability and flexibility are realized by “HORIBA ONE PLATFORM” which enables to extend the system with other ONE analyzers to a complete solution suitable for both certification and R&D purposes.
-
product
Exhaust Gas Thermocouples
HYBRID Series
The AMETEK Hybrid Series Exhaust Gas Thermocouples for Frame 7 and 9 applications have been designed, fully tested and qualified to meet OEM specifications. AMETEK has worked closely with the OEM turbine manufacturer to qualify and engine test this thermocouple as a direct replacement, or for upgrading an older style Exhaust Gas Thermocouple.
-
product
Exhaust Back Pressure Tester
33600
Use to test for clogged or obstructed catalytic converters and mufflers. Fast and easy to use - threads into Oxygen Sensor Port. Includes 12mm and 18mm adapters to fit most domestic and imported vehicles. Gage measures 2 1/2" diameter and has dual scale: 15 PSI and 1.00 Kg/Cm2. Hose is 41" long.
-
product
Engine Exhaust Particle Sizer
3090
The Engine Exhaust Particle Sizer 3090 (EEPS™) spectrometer measures the size distribution of engine-exhaust particle emissions in the range from 5.6 to 560 nm with the fastest time resolution available. Users can visualize and study the dynamic behavior of particle emissions that occur during transient test cycles, during the first few seconds of a cold start, or during regeneration of a particle trap or diesel particulate filter (DPF).
-
product
Laser Spectroscopic Motor Exhaust Gas Analyzer
MEXA-ONE IRLAM
The MEXA-ONE IRLAM is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.HORIBA's innovative infrared gas analysis technology, IRLAM™ (Infrared Laser Absorption Modulation), enables low-noise, high-precision measurement of four nitrogen compound gases (NO, NO2, N2O, NH3) in the low concentration range.
-
product
Motor Exhaust Gas Sulfur Analyzer
MEXA-1170SX
The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen sulfide and all organic sulfur compounds. An inorganic sulfur mode will analyze hydrogen sulfide and the sulfur oxides. The final operational mode will analyze just the sulfur oxides. Any one of these modes can be selected by the user from a front panel interface.
-
product
Exhaust Gas Analyzer for the Measurement of Petrol-, CNG-, and LPG- Powered Vehicles
MET 6.1 | VP 135117
Maschinenbau Haldenwang GmbH & Co. KG.
The MET 6.1 exhaust gas analyser is designed for the measurement of petrol-, CNG- and LPG-powered vehicles as well as the precise analysis of the gas components HC, CO, CO2, O2 with lambda value calculation. The MET 6.1 stands out for its innovative condensate separation thanks to an active water separator. In addition, low weight, compact design and short warm-up time ensure easy handling.
-
product
Exhaust Gas Analysers
Designed specifically for the busy workshop environment, it incorporates the fastest MoT test procedures, developed in-house here at Boston and using our newly released SW900 product control software.
-
product
Exhaust Gas and Wheel Space Thermocouple
EGT
AMETEK Exhaust Gas (EGT) and Wheel Space Frame Turbine Thermocouples meet the specific operational and performance requirements for REPLACEMENT and RETROFIT Frame gas turbine applications. AMETEK's expertise in solving creep, stress, rupture, corrosion, EMF drift, and other problems affecting sensor performance has resulted in a robust line of single and dual element thermocouple designs. Typical applications include wheel space and exhaust gas temperature monitoring.
-
product
Exhaust Fan
CF-400-X
This UL approved exhaust fan is typically installed in cabinet top panels, but has many applications. This fan requires a 10” diameter area and extends approximately 4” inside the panel.
-
product
Exhaust Gas Temperature Thermocouple
LM6000 T4.8
The latest and most capable LM6000 gas turbine exhaust gas temperature (EGT) probe from AMETEK offers the longest possible life. AMETEK is the original EGT probe supplier for CF6 aircraft engines. LM2500, LM5000, and LM6000 industrial gas turbines and now brings to market an EGT probe with new materials and a new design. The latest LM6000 T4.8 EGT thermocouple is OEM qualified and incorporates, many improvements over any previous products. Materials are carefully selected to ensure long product life and superior performance. Specifically, a new single crystal alloy for the probe support significantly improves high temperature mechanical strength. In addition, the thermocouple sheath material increases high temperature oxidation and creep resistance. Best of all, AMETEK's new T4.8 thermocouple is completely interchangeable so that it can be used on all LM6000 applications.
-
product
FTIR Exhaust Gas Analyzer Direct Measurement Type
FTX-ONE-CS/RS
The FTX-ONE offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4, and CO2, from (engine) direct exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.
-
product
OEM Gas (CO/HC) Analyzer
BE-150
The BE-150 is the palm-top sized OEM NDIR analyzer capable of measuring CO, CO2 and HC in automotive exhaust gases. High accuracy and reliability, the BE-150 meets OIML Class 0 and complies BAR-97 & GB18285-2018 specifications.
-
product
Saab Oxygen Sensor
KS60113 - Saab
Konstar Electric Industrial Co., Ltd
An oxygen sensor, also known as a lambda sensor, continually detects the oxygen content in the exhaust gases of an engine. The oxygen sensor output signal informs the vehicle's ECU (Electronic Control Unit) whether the AFR (Air-Fuel Ratio) is lean or rich. Based on this, the ECU adjusts the amount of fuel injected into the engine to achieve an optimal AFR.
-
product
Multi-Stage Injection Measurement System
Common rail fuel injection system in diesel engines is a fuel injection system which improves output performance and fuel consumption by purifying exhaust gas (soot, NOX) and reducing noise and vibration.The fuel is completely burned by being sprayed in the form of mist which burns easily at high pressure, and furthermore the combustion timing is optimized with electronic control.In this common rail injection system, injection timing by an electric controlling has great effect on the performance of an engine. So measurement of injection amount, injection rate, and injection timing are very important. FJ-8000 series Multi-Stage Injection Analyzer is able to measure those parameters for every 1 cycle by simulating in the environment which is near to an actual vehicle running.
-
product
Motor Exhaust Gas Analyzer
MEXA-1300R
MEXA-1300R is a motor exhaust gas analyzing system for two and four stroke engine assembly lines and has an integrated sample handling system for removal of oil and moisture. The measurement of CO, CO2, HC and O2 (optional) in exhaust gases is made simply by inserting the sample probe into the tail pipe. AFR and Lambda are also calculated from the exhaust gas concentrations.
-
product
Humidity and Temperature
T3000 - serie multimeasure
Whether you need to conduct analyses of supply and exhaust air flows, condensation, poor machine cooling, porous seals, climate fluctuations, heat build-up, excessively dry or damp materials or carry out leak detection on pressure tanks or line systems – both for preventive maintenance and building diagnostics and damage analysis – you can handle the most diverse tasks with a single measuring device!
-
product
Lambda Oxygen Sensor
KS60002
Konstar Electric Industrial Co., Ltd
An oxygen sensor, also known as a lambda sensor, continually detects the oxygen content in the exhaust gases of an engine. The oxygen sensor output signal informs the vehicle's ECU (Electronic Control Unit) whether the AFR (Air-Fuel Ratio) is lean or rich. Based on this, the ECU adjusts the amount of fuel injected into the engine to achieve an optimal AFR.
-
product
Sound Level Meter for Automotive – Car Noise Emission Inspection
HD2010MCTC
The level of noise produced by vehicles shall comply with standards prescribed by international regulations. During car inspections, horns and exhaust devices must be in good condition and comply with the requirements.
-
product
On-board Emissions Measurement System for NH3/N2O
OBS-ONE IRLAM Unit
The OBS-ONE IRLAM unit is an on-board emissions measurement system for analyzing the NH3/N2O under real-world driving conditions and supports our customer’s future regulatory development.The IRLAM unit combines with the GAS unit and the PN unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).
-
product
On-Board Systems
OBS-ONE series
HORIBA developed the OBS-ONE series on-board emission measurement system in response to new requirements for exhaust emissions measurement from vehicles being driven on public roads (Portable Emissions Measurement Systems - PEMS). This development has been made possible by reducing the dimensions and power consumption of laboratory grade analyzers and ensuring that the system components have excellent vibration resistance. The OBS-ONE series continuously measures not only the concentration of CO, CO2, THC and NOx, but also measures exhaust fl ow rate and A/F ratio to calculate mass emission and fuel economy.
-
product
High Temperature Charge Mode Accelerometers
Charge mode output accelerometers from PCB® use piezo-ceramic sensing elements that output an electrostatic charge signal proportional to the applied acceleration. These sensors can operate at extremely high temperatures because they do not contain the built-in signal conditioning electronics that limit the temperature range of ICP® accelerometers. Charge mode sensors are used in the testing of gas and steam turbines, jet engines, high power motors, exhaust systems and automobile engines where temperatures can range from 500° F (260° C) to 1200° F (649° C).
-
product
Emissions Testing
One of the main aims of environmental protection is to suppress harmful emissions or reduce them as much as possible. Typical examples of emissions include gaseous and particulate pollutants emitted by furnaces, odor emissions and particulate emissions from waste tips. Help protect the climate and ask us to measure the emissions created by your facilities.Our experts will test your facility – from large-scale firing plants to biogas plants, from waste incinerators to crematoria – according to national and international standards. We can also help you reduce noise pollution, measure exhaust gases and harmful emissions, and modernize your facilities.With their extensive experience, our experts can analyze your processes and identify potential improvements. As a measurement body registered throughout Germany and internationally accredited according to ISO 17025 we are authorized to perform the legally required measurements for you.Your facilities need testing? Ask us about our emission testing.
-
product
Ancillary Test Cell Products
In addition to our innovative and industry leading AccuDyne AC Dynamometers and DynoLAB Test Automation Systems, SAKOR fully integrates a complete range of ancillary products and subsystems necessary for an advanced test cell. Examples include:*Combustion air consumption measurement and conditioning subsystems*Exhaust handling systems*Fuel consumption measurement and conditioning subsystems*Coolant and oil conditioning systems*Throttle actuators*Spark/Fuel controls*Combustion analysis systems*Complete exhaust emissions analysis systems (per 40 CFR 1065 regulations)*Sound attenuating (up to STC 52) test cell enclosures with several fire suppression options*Process water evaporative cooling tower
-
product
Fluid Property Sensors
TE Connectivity (TE) offers distinct fluid property sensor technologies to measure fluids. Our tuning fork technology is coupled with efficient software algorithms for accurate measurement of viscosity, density, and dielectric constant. Dedicated applications for our DEF sensors include oils quality sensors (engine, hydraulic, transmission), fluid monitoring, and others. Our urea quality SCR sensors, based on Ultrasonic Technology (UST), perform an analysis of the Diesel Exhaust Fluid (DEF) fluid to provide urea concentration and secure mis-filling protection to the Selective Catalytic Reduction systems. Our highly reliable reed switch technology is combined with temperature measurement for DEF level sensing.
-
product
Stack Gas Analysis System
ENDA-5000 series
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
product
Car Oxygen Sensor
KS60044
Konstar Electric Industrial Co., Ltd
An oxygen sensor, also known as a lambda sensor, continually detects the oxygen content in the exhaust gases of an engine. The oxygen sensor output signal informs the vehicle's ECU (Electronic Control Unit) whether the AFR (Air-Fuel Ratio) is lean or rich. Based on this, the ECU adjusts the amount of fuel injected into the engine to achieve an optimal AFR.
-
product
Back Pressure Tester
TU29P
Enables Technician to test exhaust back pressure thru oxygen sensor. Oxygen Sensor adapter includes M12 & M18 thread.Special Gauge has two multi-colored bands - idle and 2500RPM, with pressures shown in PSA and bar.