Thermocouple Calibrators
-
Product
Electromechanical Calibration for Transducer
ELCS-500
-
Jinan Testing Equipment IE Corporation
The electromechanical calibration system is specially designed for the calibration of transducers. The calibration for transducer can calibrate the load cell accuracy within +/- 0.5%.
-
Product
Calibration Test Benches
-
Nagman Instruments & Electronics Pvt. Ltd
Nagman’s wide range of Calibration Systems – Test Benches, Workstations, Bench-tops & Mobile Units – are designed & executed to serve as Powerful tools for Total Quality Management & ISO Conformance with Accuracies Traceable to International Standards and Total Solution to all Calibration requirements.
-
Product
Legendary Calibration Oscillator
LCO Series 3.5” x 2.5” x 0.6”
-
*Connectorized Package *Low Output Power Variation (±0.05 dB)*Output Power to +10 dBm Available *Optional Internal Reference
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
-
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Multifunction Calibrators
-
These field and bench calibrators source, simulate, and measure pressure, temperature, and electrical signals with exceptional precision. They can automate calibration procedures, store data, and even calibrate and troubleshoot HART-compatible devices. Our bench calibrator can even be used to calibrate our field calibrators. Also find here 5.5- and 6.5-digit bench multimeters for to assist with a variety of general test and calibration applications.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
Calibration Units
-
Optical Stroboscope and Tachometer European Calibrator Unit was originally designed for in-house test and calibration of our comprehensive range of Digital Optical Tachometers, Optical Speed sensing products and Stroboscopes.
-
Product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Calibration Hangers And Weights
-
Calibrated Dead Weight are the official means by which torque analyzers and torque sensors are calibrated and are traced to National or International Standards, such as N.I.S.T, ISO and others. Many industries like as medical, aerospace, nuclear and others continuously calibrate their measuring equipment to comply with government regulations. For companies that prefer to have calibration capabilities in-house when their calibration requirements become extensive, they need calibration equipment.
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745685-T01
-
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Thermocouple Vacuum Gauge Tubes
DV-6 Series for Medium Vacuum
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
Product
Relay Test Set and Universal Calibrator
CMC 256plus
-
The CMC 256plus is the first choice for applications requiring very high accuracy. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibrator.
-
Product
Pressure Calibration
-
Trescal provides full Pressure Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Pressure Calibration services can be delivered at your site or at our lab. Accreditations for our pressure calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Portable Analyzer and Calibrator
-
ECD’s portable analyzer and calibrator product lines are a simple convenient way to obtain fast, accurate pH and ORP measurements. They provide a milliVolt output signal for fast field analysis of samples, calibration verification, or trouble-shooting of installed sensors.
-
Product
Calibration & Demag.
Model 5655
-
The model 5655 is a capacitive-discharge magnetizer / demagnetizer / calibration unit.
-
Product
Calibration
EMC Test Antennas
-
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
Product
K Thermocouple Penetration Probe
TP659
-
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
Product
Calibration Plates
-
MVTec provides precision-manufactured calibration plates to its customers. The plates are necessary to accurately calibrate a machine vision setup. MVTec’s calibration plates are available in different materials and in sizes ranging from 2cm×2cm up to 32cm×32cm. Contact your local distributor for assistance with choosing the right plate size and material for your application.
-
Product
Calibration Sources
-
Up to an absolute accuracy of 60 MHz standard HighFinesse Wavelength Meters feature auto-calibration by integrated calibration sources. This way highest accuracy and stability of measurements with our wavemeters is guaranteed.
-
Product
Thermocouple, Module, ITA, iCon Series, 96 Position
510161110
-
Primary mating module 510160110. (May mate with other Receiver modules, as well.)
-
Product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
-
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
Product
Pressure Calibrator
HPC40
-
AMETEK Sensors, Test & Calibration
The HPC40 Series handheld pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -20 to 50°C. You can count on the same accuracy whether measuring pressure, current, voltage, or temperature.
-
Product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
-
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
RH Calibrator / Dew Point Generator
-
Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.
-
Product
Test Equipment Calibration Services
-
Custom Calibration Solutions, LLC
Custom Calibration Solutions assists customers in meeting or exceeding individual business goals by striking the ultimate balance between quality objectives and cost. We can optimize any existing test equipment calibration program by combining the use of our proprietary procedures in conjunction with the most appropriate standards for each calibration task.
-
Product
Qualified Hermetic EGT Thermocouple Upgrade
-
FIT-IT & FORGET-IT Eliminate Exhaust Gas Temperature (EGT) thermocouple concerns with AMETEK's new EGT thermocouple product offering for Frame turbine applications. AMETEK has worked closely with the turbine OEM to design and engine test this thermocouple as a direct replacement and upgrade for all new and existing EGT thermocouples. The new EGT thermocouples are qualified and meet all design specifications.
-
Product
NIST Calibration for D410-A
D410-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Basic Quad J-Type Analog Thermocouple Amplifier
SEN-30103-J0
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
MAX31855 T-Type Thermocouple Arduino Shield
SEN-30004-T03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino.Each order comes with one board and a set of four female, long extension, headers that can be soldered to the board. If stacking two of these modules on top of each other, please order both a Ch 0-3 and a Ch 4-7 board, as well as an additional set of headers for stacking. We're working on sourcing even longer headers, but the ones currently available are not long enough to stack as-is (they need to be double-stacked).The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or MegaNote: we also offer a universal version of this board in a smaller for factor, the SEN-30003-T.FeaturesType-specific, miniature-sized vertical thermocouple connectors (vertical flat blades, see pics)Measures four (4) thermocouple channels, full extended range.Boards are stackable. Up to 8 thermocouple channels may be connected to an Arduino.14-bit SPI interfacePlugs directly into an Arduino Uno or Mega form factor with built-in voltage level translation on-board.Standard Arduino female headers required for easy configuration, one set included with order (1-6x1, 2-8x1, 1-10x1 0.1" female stackable headers), not soldered on.Detects shorts to GND or VccDetects open thermocoupleOther versions available (K, J, and T stocked). Contact Customer Service to place a custom order.Mounting holes for 4-40 sized screwsConnections are spaced for 0.1" pin headerDesigned, manufactured, tested and shipped from the USA The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega