Thermocouple Calibrators
-
Product
Trace Level Portable Gas Calibrator
Model T750U
-
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
Product
Temperature Calibration Software v5.1
MET/TEMP II
-
MET/TEMP II software allows you to easily automate the calibration of a wide range of temperature sensors. It provides a comprehensive temperature calibration solution that allows you to test large quantities of sensors, calculate characterization coefficients, and print calibration reports. You can standardize comparison or fixed point calibrations and use multiple temperature sources or references in one test.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
Current Probe Calibrator
KSZ
-
PMK Mess- und Kommunikationstechnik GmbH
Since Current Probes are often exposed to hard working conditions, a performance check is recommendedbefore every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 1000 A with an accuracy better 1%. They qualify for calibration and adjustment of Current Probes.
-
Product
Configurable Thermocouple Transmitter
HD778TR1
-
Configurable 4...20 mA/20...4 mA 2 wire temperature transmitter for K, J, T, N thermocouples.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
Product
Multi-Cal Pressure Calibrator
MC
-
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
K Thermocouple Immersion Probe
TP750
-
Immersion “K” Type thermocouple probe. Tolerance according to IEC 60584-2 standard.
-
Product
Class 1 Sound Level Calibrator
AWA6221A
-
Hangzhou Aihua Instruments Co., Ltd.
Model AWA6221A sound calibrator comply with the standard IEC 60942 Class 1.
-
Product
K Thermocouple Magnetic Contact Probe
TP757
-
Magnetic thermocouple type “K” probe for measurements on magnetic metal surfaces.
-
Product
Decade Box, Calibrated W/D & U, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL DU
-
The 72-7270 CAL DU from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
HiPot Calibrator
Model 9102
-
The 9102 Hipot Calibrators is specially designed standard devices for instrument calibration lab. The 9102 can simulate multiple loads and apply to various Hipot testers. These calibration equipment can save manufacturers a great deal of regular calibration fee.
-
Product
J-Type Thermocouples (Ungrounded) (32 deg F to 900 deg F )
745685-J02
-
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
K Thermocouple Surface Probe
TP772
-
Surface thermocouple Type "K" probe. °C max: 400. Response time: 3 s.
-
Product
Speed-O-Calibrator
16470
-
The Speed-O-Calibrator consists of two sections, control box and drive unit. The control box is stored inside the drive unit for easy portability. The control box weighs less than 6 lbs and is used in the cab of a locomotive to control the speed of the Axle Alternator Drive Unit. The Drive Unit drives the Axle Alternator at various speeds while the user verifies that the correct speed is displayed in the cab. The test system provides a complete test of the speedometer system, including all types and paddle lengths of Axle Alternators.
-
Product
6GHz SMA Calibration Kits
CAL-SMA-6B
-
The CAL-SMA-6B Basic calibration kit provides the elements for performing Open–Short–Load and Through calibrations for one and two port VNA measurements.
-
Product
Acoustic Calibrators
-
We offer a range of Class 1 and Class 2 acoustic calibrators for the field calibration of any make or model of sound level meters and noise dosimeters.
-
Product
Class 2 Sound Level Calibrator
SPC70
-
The SPC70 is a Class 2 sound level calibrator suitable for periodic testing of sound level meters and verifying their accuracy before and after readings, in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB. The output is accurate to 0.5dB with low levels of harmonic distortion. The SPC70 is compatible with the Martindale SP79 Class 2 Sound Level Meter and other meters with microphones up to 25mm.
-
Product
Hydraulic Calibration for Load Cell
HLCS-10000
-
Jinan Testing Equipment IE Corporation
The Hydraulic Calibration System is specially designed for the calibration of load cells with higher capacity. The Calibration for Load Cell can calibrate the load cell within +/-1%.
-
Product
Automated CMM Calibrated for High-Production Shop Floor Inspection
CMM Master
-
The CMM Master provides process control by delivering optimal price and performance to your application. The system brings highly repeatable, thermally insensitive, versatile, and programmable inspection to the shop floor.
-
Product
MAX31855 K-Type Thermocouple Arduino Shield
SEN-30004-K47
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855K supports a measured temperature range of -270C-1372C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Meter Test & Calibration
-
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of products for meter test and calibration including portable power source, standard reference meter and meter test system. All products are accredited to the highest production standards with different options of measurement accuracy (class 0.05 and class 0.1).These enable them to cover different applications for test and calibration of different types of energy meters, electric transducers, indicating meters and so on.
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
Horizontal Calibration Instruments (Lab)
THV
-
The horizontal THV instrument has been designed for calibration and certification of gauging equipment of small dimension. It allows easy and precise checking of plug gauges, ring gauges, thread plug gauges, test and dial indicators as well as measuring of high precision production parts.
-
Product
SparkFun Qwiic Thermocouple Amplifier
MCP9600 (Screw Terminals)
-
The MCP9600 Breakout is a high accuracy Thermocouple Amplifier equipped with an I2C interface, accessed over our Qwiic system. Inside the chip are two temperature sensors, one for the thermocouple itself (the hot junction) and one for the chip itself (the cold junction). As a result, the MCP9600 can read both the ambient temperature and the temperature of whatever you're trying to measure! The MCP9600 can do both with a resolution of 0.0625°C, and an accuracy of ±1.5°C (worst-case). The MCP9600 Thermocouple Amplifier is one of our many Qwiic compatible boards! Simply plug and go. No soldering, no figuring out which is SDA or SCL, and no voltage regulation or translation required!
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
Product
Acoustic Calibrator
CAL250
-