Thermocouple Calibrators
-
Product
Multi-Point Calibrator
AQMS-200
-
FPI AQMS-200 dynamic dilution calibrator utilizes two mass flow controllers to perform standard zero and span calibration with up to 4 gas sources.
-
Product
Gas Calibrators and Zero Air Generators
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Product
Power Calibrator And Protection Relay Test Set
CP11B
-
Calmet Smart Calibration Devices
Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
Product
Calibration Executive Software
CalEasy Series
-
CalEasy is a full-featured, Calibration Executive software package that supports the verification and calibration of Marvin Test Solutions instruments. The software is intended for use by users that prefer to perform in-house calibration and verification for their Marvin Test Solutions instruments. By calibrating or verifying the instrument in-house, the time and cost associated with returning an instrument to Marvin Test Solutions for calibration service can be eliminated or reduced. CalEasy is also used internally by Marvin Test Solutions production to perform initial calibration and to recalibrate the instrument when received for service. This ensures that user and factory based calibration performance is similar. Depending on the specific instrument, standards instrumentation supported for calibration / verification includes a DMM, and a frequency standards module. Some modules require the use of matrix switch card.
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-1m
Cable Assembly
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-297 and 50-297 enabling calibration via an external DMM.
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard COMPACT
-
Rotary Precision Instruments UK Ltd
Designed for horizontal or vertical applications with a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
12:1 IR Thermometer w/ K-Type Thermocouple Input
INF195C
-
UEi Test & Measurement Instruments
The INF195C offers the unique circular laser targeting showing users the exact spot being measured. This 12:1 Infrared Thermometer also offers advanced features including a wider temperature range, K-Type input, selectable emissivity levels, Min/Max, average, differential, a user adjustable alarm and backed by a 1-Year limited warranty.
-
Product
Bench Power Supply, Calibrated w/D & U, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL DU
-
The 72-2690 CAL DU from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
Service, Modernization, and Calibration Serivices
-
In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.
-
Product
Spectral Irradiance / Illuminance Calibration Standards
-
Standard lamps calibrated in illuminance and spectral irradiance. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Industrial Pressure Calibrator
2271A
-
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and budgets, and expanded to cover a broad workload. The 2271A is ideal for calibration laboratories starting out in pressure calibration because it offers wide pressure measurement capabilities in a single instrument. Everything you need for calibrating pressure is included; just connect supply pressure. And your investment will stand the test of time: as your workload grows and changes, the 2271A can grow and change too. Just add measurement modules.
-
Product
Pressure Calibrators
-
We offer pressure calibrators as portable and as workshop models. Pressure measurement is performed with internal and/or external pressure modules for better flexibility. Pressure measurement ranges go from vacuum up to 1000 bar (14,500 Psi). Both gauge (vacuum and positive) and absolute pressure can be measured with same modules meaning you don’t need to buy so many module for greater flexibility. Also, intrinsically safe pressure calibrators are available for use in hazardous areas.
-
Product
Mass Flow Calibration
-
Allow instrument interchangeability without affecting your process and meet ISO 9001 requirements easily and efficiently with Process Instruments’ Mass Flow Calibration and Repair Services.
-
Product
Thermocouple Power Sensors
N8482A
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
Thermocouple Power Sensors
N8487A
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
IEC60068-2-75 Spring Hammer Calibration Device
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is mainly used for the calibration of the spring hammer, which is based on IEC60068-2-75-1997 and GB2423.55-2006 standard design and manufacture, primarily for third-party testing organization, the National immigration department and appliance-related research institutes.
-
Product
NIST Calibration for D410-A
D410-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Digital Pressure Calibrators & Gauges
-
While the industries that use digital pressure test gauges have evolved, the need for durable, insightful, and highly functional equipment remains strong. We've built our digital pressure test gauges with environmental accuracy and performance flexibility in mind.
-
Product
Universal Solution for Model-based Calibration Software
INCA
-
INCA tools are used for ECU development and test as well as for validation and calibration of electronically controlled systems in the vehicle, on the test bench, or in a virtual environment on the PC. The tools are used worldwide in over 20,000 installations in development and production projects.
-
Product
Automatic Calibration Module
ACM4509
-
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Vacuum Sensor, Thermocouple Vacuum Gauge for Rough Vacuum
DV-4 Series
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.
-
Product
4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)
CK564A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)
CK562A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30001-K
-
Breakout board for the MAX31855K digital thermocouple interface IC. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header, has a vertical mini thermocouple connector and four mounting holes for standoffs and 4-40 screws.
-
Product
N-port Calibrated Measurements
S97551B
-
The S97551B software enables full multiport error correction and measurement capabilities when using multiple USB vector network analyzers
-
Product
Seismic Transducers Calibration System
-
Calibration of the seismic sensors should be conducted in the low-frequency domain, which means, that the relative method used for calibration of the vibration transducers is not applicable since it does not guarantee the required accuracy level. The problem is that the reference accelerometers have uneven AFR characteristic in the low-frequency domain. Thus, calibration of seismic transducers requires implementation of a different approach.
-
Product
K-type Thermocouple Thermometer
6537
-
Peaceful Thriving Enterprise Co Ltd
The instrument measures the temperature by standard K-type thermocouple. It can be widely apply for measuring temperature by contacting testing object directly. There are 2 different temperatures can be measured simultaneously.