product
Wireless Ethernet Bridges
Our wireless Ethernet bridges connect your wired devices to a wireless network - explore our range of advanced solutions.
-
product
USB Connectivity Bridges
USBXpress
Silicon Labs USBXpress devices are highly optimized solutions that enable designers to easily add USB to existing and new applications. These fixed function devices provide the easiest method to add USB without the need for any firmware or driver development. USBxpress portfolio supports several USB to serial bridge devices including human interface (HID) devices and USB Audio devices.
-
product
Resistance Thermometry Bridges
By using built-in or external standard resistors, resistance thermometry bridges measure resistance ratios with high accuracy, which are indicative of the temperature, among other things. These instruments are not only used in the field of temperature measurement, but − due to their high accuracy − also in electrical laboratories.
-
product
Precision Temperature Bridges - AccuBridge® Line
Measurements International Ltd.
Multiple Display Modes Including: Temperature (°C, K, °F), Resistance, Ω, Ratio, ADCC Technology, Accu-T-Cal™ Software (NMI Designed).
-
product
PCIe Switches And Bridges
Modern data centers require solutions that offer maximum performance with minimal power consumption. While compute and storage devices have native PCIe for internal communication, they all use different technologies, such as Ethernet or InfiniBand, to connect externally.
-
product
Portable Bridges
A range of affordable battery operated test equipment for the measurement of resistance.
-
product
Resistance Bridges - AccuBridge® Line
Measurements International Ltd.
The Resistance Ratio Bridge from Measurements International is the next generation replacement. Measurements International is pleased to release the next generation room temperature Direct Current Comparator Resistance Ratio Bridge.
-
product
Directional Couplers & Bridges
A complete line of coaxial single and dual port directional couplers, and bridges for isolating, separating, and combining RF and microwave signals in such applications as power monitoring, source leveling, swept transmission and reflection measurements.
-
product
Wireless Bridges
Transform any device into a wireless device for greater flexibility and mobility, with support for industry leading security including WPA and WPA2 with 802.1X authentication.
-
product
(DCC) Resistance Bridges
Direct Current Comparator (DCC) Resistance Bridges. Unique innovations in 6622A design and modularity means users no longer have to decide what Bridge satisfies current requirements as well as future requirements. Optional modules allow for normal, high ohms, and low ohms measurements without having to purchase multiple bridges as per competitive products.
-
product
Software
SSI-TRES
Was developed to read and edit Plug and Play Smart Sensors that are compliant to the IEEE 1451.4 Standard. TEDS, or transducer Electronic Data Sheet, is a set of electronic data in a standardized format defined within the IEEE 1451.4 standard. This data specifies what type of sensor is present, describes its interface, and gives technical information such as sensitivity, bridge type , excitation, etc. This information is stored in an EEPROM chip attached to the sensor. By having this chip, the sensor can identify and describe itself to the network and or Smart Load Cell Meter (DPM-3), thereby easing automatic system configuration.
-
product
Strain Sensors
Conventional strain sensors are based on strain gage technology. In order to effectively measure the strain values in a force or load measurement application, a full, 4 element strain gage bridge circuit is utilized. The configuration is known as a Wheatstone Bridge Circuit. A Wheatstone Bridge has a very linear output in it’s midrange. That being considered +100% to -100% of range. Unfortunately, a Wheatstone Bridge becomes non-linear above the upper and lower extremes of range. Therefore, significant errors can result above the end points when attempting to take precision measurements. It is particularly important to take accurate measurements in some R&D or control applications. To avoid the mentioned error issues, PCB manufactures quartz piezoelectric strain sensors that output the same mV/microstrain sensitivity throughout the entire useful range. Thus, accuracy is improved and control requirements are enhanced that may occur at positive extremes of the measurement range. The models RHM240 and model 740B02 series sensors are the strain sensors for these applications.
-
product
Bench Meters
LCR Meters
The measuring objects of LCR Meters are the parameters of impedance components, including resistance R, inductance L, quality factor Q, capacitance C and loss factor D. The selection of digital bridge should consider the highest frequency, test accuracy, test speed and DCR test function of the tested device.
-
product
Capacitance Bridge
1620
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
product
Sol Manual Precision Measurement Systems
Sol
The Sol Vision System implements new technologies to provide speed and accuracy on a reliable and affordable measuring machine. The Sol bridges the gap between manual and automated measurement systems.
-
product
Signal Conditioning and Filtering
MSXB 067
The MSXB 067 Signal Conditioning Expansion Board provides analog signal conditioning for strain gauges, load cells, RTDs, and other resistive sensors. MSXB 067 provides a flexible interface for quarter-bridge, half-bridge, and full-bridge sensors, with two to six wires for each sensor, with or without voltage sense feedback. A small daughterboard supports user-supplied bridge completion resistors.
-
product
3U And 6U CPCI CARRIER Board
MS 1715
*Bus Interface:- 32 Bit/64 bit PCI Bus with cPCI Interface*Two slots of 32/64 bit PMC connector interface*Speed of operation up to 66MHz*64 bit, 66MHz PCI Bridge based design*Self Test future
-
product
Ethernet Connectivity for Controlling ARINC-429 Channels and Auto RX Bridging
ENET-A429
eNet-A429™ is an innovative product that provides “remoting” of ARINC operations on 10/100/1000 Ethernet IP/UDP local area networks (LAN). eNet-429 is a small, low-power, rugged device that provides connectivity for 1-8 ARINC 429/575/573/717 Channels – Ideal for remoting ARINC connections for in-field applications or point-point lab usage.
-
product
Acquisition Of 16 Displacement Transducers
APCI-3701-16
PCI interface to the 32-bit data bus Acquisition of 16 inductive displacement transducers (Half Bridge, LVDT) 16 input channels ± 10 V 16-bit resolution Measuring frequency up to 100 kHz Conversion can be triggered through software End of conversion can be inquired through software Possibility of interrupt through digital input channels (when a data or a time value is exceeded) PCI-DMA access Onboard FIFO buffers Sequence RAM 16 isolated digital I/O, 24 V Software operation Supported inductive transducers for APCI-3701Standard board APCI-3701-8 or APCI-3701-16Transducer type:
-
product
Torque Transducers
The technology behind our torque sensors are strain gages. These gages are arranged into a Wheatstone Bridge circuit, which converts the physical, mechanical force into an electrical signal that can be filtered, displayed, and recorded for further processing. This very accurate radiometric electrical signal is proportional to the applied mechanical force.
-
product
Resistance Bridges
Provides the best in measurement uncertainties for Direct Current Comparator (DCC) Resistance Bridges. Unique innovations in 6622A design and modularity means users no longer have to decide what Bridge satisfies current requirements as well as future requirements. Optional modules allow for normal, high ohms, and low ohms measurements without having to purchase multiple bridges as per competitive products.
-
product
12 Pulse Diode Bridge Rectifiers Inside Fiberglass Plenums, P/N 5872C4-2
- 12 Pulse Diode Bridge Rectifier, P/N 5872C4-2- Each diode is rated for 60 Amps, 1800 Volts peak- Dimensions: 50″L x 40″W x 20″H approximately- Four 10″ fans are used for coolingFour 10″ fans will force cool from the bottom of the Plenum. 12 diode assemblies (each diode consists of nine diodes in series are integrated together inside the Plenum). The output is rated for 3000 VDC, 80 Amps.
-
product
RTD Data Logger
RTD Data Logger is the most commonly used sensors for measuring temperatures in various industries. These are positive temperature coefficient resistive sensors and Pt100 is the most commonly used type of RTD sensor which has 100 ohm resistance at 0 C. IM2000 series RTD data loggers offer bridge measurement technique to compensate for effect of wire length. In addition logger has facility to program offset so that the measurements are more accurate.
-
product
SCADACore Cloud-Connect
SCADACore’s Cloud-Connect products bridges your sensors and field operations to our fully-managed Web SCADA solution. SCADACore delivers complete end-to-end solution to bring field data to you anytime, anywhere.
-
product
CompactPCI
cPCI4IP
The cPCI [CompactPCI] compatible cPCI4IP design adds 4 Industrypack compatible slots to your cPCI host. The cPCI4IP acts as an adapter, converter, carrier, or bridge between the cPCI bus and your IndustryPack hardware. The cPCI4IP is a 6U 4HP cPCI design with 4 IP slots.
-
product
Load Cell DIN Rail Signal Amplifier
LCD20
Our intelligent strain gauge bridge amplifier is a compact, stackable microprocessor based unit specifically designed to control and monitor process applications. Flexible connection to most load cells, pressure or strain gauges over a wide range of sensitivities. The unit provides isolated current 4-20mA and voltage 0-10V analogue outputs and two digital inputs. Two set point relays can be configured to set thresholds such as net, gross, peak and valley. Powered from a wide ranging DC supply, the DIN rail amplifier is supplied with 2 part screw connectors for ease of installation.
-
product
PCIE Module For PCIe Bus Expansion
PCI113
PCI113 is VadaTech second generation PCIe expansion module. The PCI113 is a high-speed 20Gbps bridge from the host PCIe bus to VadaTech’s carrier and Rear Transition Module (RTM) products such as the ATC104/114/118/117/119, ART114, μTCA chassis, etc. The different carriers host different I/O modules such as PMC/PrPMC, AMC, PCI-X and PCIe edge modules. This concept allows any of the available I/O modules in these standard form factors to be integrated quickly and easily into an AdvancedTCA or μTCA subsystem. The PCI113 allows expansion among multiple μTCA chassis or expansion into other chassis that are not ATCA or μTCA based.The PCI113 is a single module PCIE based on the PCISIG specification. The PCI113 provides a PCIe x4 link infiber/copper via front panel QSFP. The dual front I/O allows expansion into two separate systems independently. The upstream port must not have spread spectrum PCIe clock enabled.
-
product
RF Bridge, 50 Ohm, 300 kHz to 6 GHz
86205A
The Keysight 86205A high directivity 50 ohm RF bridge offers unparalleled performance in a variety of general-purpose applications. It is ideal for accurate reflection measurements and signal leveling applications.
-
product
Mezzanine System
5085
ECM P/N 5085 provides two channels of 24 bit A/D conversion suitable for high resolution low speed applications, which include bridge circuits, thermocouples, RTD and voltage measurements. For bridge applications each channel provides a fused +5 Volt or a current source drive.
-
product
Transformer Loss Measuring Bridge
MLS 7100
The MLS 7100 transformer loss measuring bridge was especially designed to greatly simplify the determination of transformer core and copper losses – an ideal choice when working on site. The measuring bridge features open circuit as well as short circuit measuring. Many transformers can be directly connected to the MLS 7100 without needing further transducers.